HomeMy WebLinkAboutPR17-0124DIAMOND BAR
a
CITY OF DIAMOND BAR
DEPARTMENT OF COMMUNITY & DEVELOPMENT SERVICES
21810 Copley Drive, Diamond Bar, CA 91765 PRESS
(909) 839-7020 Fax: (909) 861-3117 Building Inspection Hotline (909) 839-7027 FIRMLY
BUILDING PERMIT APPLICATION www.cityofdiamondbar.com building@diamondbarca.gov
JOB SITE ADDRESS O 5- f,.-
APN LOT TRACT
OWNER Gi
ADDRESS�SicL2-
CITY ZIP tM TEL. —
APPLICANT JQa-&- TEL. Wit/ Y S-Vl 9
CONTRACTOR S E %-Y
ADDRESS /:� , ScK L N�.1L_
CITY u Aµ> r ZIP (' & TEL.
ARCH/ENG/
DESIGNER
ADDRESS
CITY ZIP TEL.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the reason(s)
indicated below by the checkmark(s), I have placed next to the applicable item(s) [Section 7031.5, Business and
Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair, any
structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she
is licensed pursuant to the provisions of the Contractor's State License law (Chapter 9) Commencing with Section
7000 of Division 3 of the Business and Professions Code] or that he or she is exempt from licensure and the basis for
the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty
of not more than five hundred dollars ($500).
U I, as owner of the property, or my employees with wages as their sole compensation, will do U all of or U portions
of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds
or improves the property, provided that the improvements are not intended or offered for sale. If however, the building or
improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built
or improved for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who
builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State
License Law.).
U I am exempt from licensure under the Contractor's State License law for the following reason(s):
Date: Sign:
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one
year prior to completion of the improvements covered by this permit,l cannot legally sell a structure that I have built as an
owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the
applicable law, Section 7044 of the Business and Professions Code is available upon request when this application is
submitted or at the following Web site: hffp/www.leginfo.ca.gov/calaw.htmi,
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
C LICENSE CLASS: e D LIC. NO.: 995Wicse
EXP. DATE: f Z 3 CONTRACTOR:
WORKER'S COMPENSATION DECLARATION
I HEREBY AFFIRM UNDER PENALTY OF PERJURY ONE OF THE FOLLOWING DECLARATIONS:
I have and will maintain a Certificate of Consent to Self -Insure for Worker's Compensation, as provided by
, Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
YI have and will maintain Worker's Compensation Insurance, as required by Section 3700 of the Labor Code, for
the performance of the work for which this permit is issued. My Worker's Compensation Insurance Carrier and
Policy Number are: ^ ,-
CARRIER •Zu'r ' v�
POLICY NUMBER L.AJ C-C7 ! S' ]?C�i
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS $100 OR LESS).
I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to
became subject to the Worker's Compensation Laws of California. And agree that if I should become subject to the Worker's
Compensation provisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
DATE: APPLICANT:
WARNING: Failure to secure Worker's Compensation coverage is unlawful, and shall subject an employer to criminal
penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of the compensation,
damages as provided for in section 3708 of the labor code, interest, and attorney's fees.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a Construction Lending Agency for the performance of the work for
which this permit is issued (Sec. 3097, Civ. C.).
LENDER'S NAME:
LENDER'S ADDRESS:
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and
county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to
enter upon the above -mentioned property for inspection purposes.
PERMITTEE NAME (PRINT)
1 2-
SIGNATURE OF PERMITTEE DATE
APPLICATION DATE: ll`z-- r1 ' In! nP/Cn# Y?rn - � �
ISSUE DATE: ZO 1 ;, PERMIT# : 7" 1\ 1 - Q `1 2
TYPE CONST. OCC GROUP:
/j
Scope of Work Z! V ci
# DWEL. UNITS If STORIES
'y-a e",
# BEDROOMS
DESCRIPTION
SQ. FT.
FACTOR PSF
ADJ. AREA/VALUATION
SFR/ADD/REM
Garage/Carport
w
Patio/Deck
-
w
rl
Pool/Spa
ZRe
-Roof
Commercial
m
Valuation:
Adj. Area:
QUANTITY
DESCRIPTION
FEE
U
c�
w
w
co
m
J
a
J
a
ZU_
Q
x
U
CONSTRUCTION:
PLAN REVIEW: $
Z(o q I
ELECTRIC:
PLUMBING:
MECHANICAL:
INSPECTION FEE:
ISSUANCE:
"}2 .2_q
SMIP:
%po
ENERGY P/C:
ENERGY PERMIT:
RETENTION FEE:
PRE-ALT FEE:
yvn. OD
BASF:
tt
PLOT PLAN:
ZONING CLEARANCE:
TOTAL FEES $ '
COMMENTS:
1401.11
P/C: PAID BY:
RECEIPT a 3 33�-�1 PAID BY: • �—A()ICIS
VALIDATION: S" h
VALIDATION: _ rs
WHITE — Department Copy, YELLOW — Finance Copy, PINK — Assessor Copy
CITY OF DIAMOND BAR
INSPECTION RECORD
COMMENTS:
Assembly Bill 2188 applies only to residential rooftop solar energy systems
that are no larger than 10 kilowatts or 30 kilowatts thermal.
This form conforms to Assembly Bill 2188.
Residential Photovoltaic Power Systems
Permit Issuance Checklist
Please complete the following information to subunit for Building & Safety plan check.
APPLICANT completes this box.
Address: Z0 Y y s` (T�V- ; �� s C,1.-` APN: Zone:
Lot Size: S.F. Average Slope: %
C?
Technology: (check one): Building Integrated Roof -Mounted Panel/Ground-Mounted Panel
System size and power: Number of panels: t. Z - Total square feet: sq.ft. -3, i Z kW (if electric)
Are the property lines correctly dimensioned on the plans? (circle one) Yes No
If Ground -Mounted: Max. height of system, (i.e. distance from top of panel to natural or finished grade):
If hoof -Mounted: Max. height above roof, (max.distance from top of roof to top of panel):
If framing is over eight inches (8") off roof or ground, is it screene ? (circle one) Yes No %A
Are the panels proposed on a permitted structure? (circle one) Yes No N/A
Panel directional orientation, (check one): West Southwest South Southeast East
System visibility from nearby public streets, parks, or trails, (circle one): Not Visible, CMedium, High
If "no" to any of the above, see the Planning Division.
COUNTER PLANNER completes the remaining foram.
1. Zoning
VYes ❑No a. Does the proposed project meet the setback requirement&(or is it an allowed
encroachment)? Front setback ft. interior setbacks ft.
P/A ❑Yes ❑No b. If ground -mounted: Does the project comply with setbacks and lot coverage
requirements?
P(es ❑No c. Are the panels proposed on a permitted structure?
Pes ❑No d. Are the property lines correctly dimensioned on the plans?
2. Design_
IO'%es ❑No a. Is there an open/pending project for the property?
❑Yes [!SNo b. Will the system be obscured from public view, i.e. as viewed from a public
street, sidewalk, park, beach or trail, is it completely hidden by a parapet, located
behind a residence, down a private driveway not visible off site, etc.? Consider
all potential public views of the site, especially on hillside properties.
If "yes", then skip to item No.6 below.
If "no", continue to item 3.
3. Is the proposed project affiliated with a historic resource (Check historic resource list)?
❑Yes NNO
Page I of 3
4. Is the proposed project on a site which includes a potentially sensitive visual resource, such as:
❑Yes ' [`To a. Hillside property (regardless of slope)?
5. Is the proposed project located in a restricted use area?
❑Yes �,No
6. The plans cannot be approved over the counter and must be routed to staff for further review. If there are Zoning
concerns ("no" to question No. 1), indicate those in the zoning activity.
[111 Yes ❑No
7. Applicant proceeds to Building & Safety Counter to continue the review (add approval notes in Zoning
Clearance file, stamp and initial three (3) sets of B&Splans and add a review fee.)
Cayes ❑No
Building and Safety requirements. Applicant shall complete the remaining form.
(Please check the correct answer for each question)
1. Applicant submitted (3) sets of plans minimum 11"x17", attach all manufacturer's specification sheets,
installation instructions, and listings.
es ❑No
2. All exposed conduits painted to match the roof is noted on the plans.
]Yes ❑No
3. In submittal, provided electrical single -line diagram clearly identifying all devices installed in the PV system and
indicating total kW rating of system.
L Yes ❑No
4. Applicant acknowledges correct circuit sizing and current calculations based off 2013 California electrical Code
Article 690.8 on plans from California state licensed electrical engineer or a California licensed contractor
classification C-46 or C-10.
[1Yes ❑No
5. Applicant acknowledges photovoltaic source and output circuits have a maximum photovoltaic of up to 600 volts
based off 2013 California electrical Code Article 690.7 on plans from California state licensed electrical engineer
or a California licensed contractor classification C-46 or C-10.
7wes ❑No
6. All pplicant acknowledges wet -stamped and signed submittal of structural calculations for wind uplift based of
ASCE 7-10 from State license civil or structural engineer. All Structural Elements shall be identified on existing
roof framing members on plans.
�es ❑No
7. Applicant acknowledges rooftop mounted photovoltaic systems shall be tested, listed and identified with a fire
classification in accordance with UL 1703. The fire classification shall comply with Table 1505.1 of the
California Building Code based on the type of construction of the building Effective January 1, 2015.
Yes ❑No
` Page 2 of 3
8. Applicant acknowledges installation of the photovoltaic system shall be in compliance based off 2013 California
electrical Code Article 690.
Yes ❑No
9. Applicant acknowledges installation of the interconnected electric power production source shall be in
compliance based off 2013 California electrical Code Article 705.
r es ❑No
10. Applicant plans are to be signed by a California licensed contractor classification C-46 or C-10. Provide signature
and license number on each sheets. Contractor who signs the document must be the one doing the work, Business
and Professions Code Section 7031.5.
[ yes ❑No
11. Applicant acknowledges that the photovoltaic system may only be installed on a permitted structure.
FYes ❑No
12. Applicant acknowledges that the photovoltaic system meets the "California Solar Permitting Guidebook":
http://opr.ca.gov/docs/California Solar Permitting- Guidebook pdf
[Yes ONo
13. Proposed project meets state fire marshal set -backs for roof mounted photovoltaic system requirements and code
section R908 CRC 2013.
Yes ❑No
Signature of Applicant: Date:
Print Name: Ha14t) -�
I -z. - 2-7 - / W
Page 3 of 3
IL
ABBREVIATIONS I ELECTRICAL NOTES � JURISDICTION NOTES
A AMPERE
AC ALTERNATING CURRENT
BLDG BUILDING
CONIC CONCRETE
DC DIRECT CURRENT
EGC EQUIPMENT GROUNDING CONDUCTOR
(E) EXISTING
EMT ELECTRICAL METALLIC TUBING
FSB FIRE SET —BACK
GALV GALVANIZED
GEC GROUNDING ELECTRODE CONDUCTOR
GND GROUND
HDG HOT DIPPED GALVANIZED
I CURRENT
Imp CURRENT AT MAX POWER
Isc SHORT CIRCUIT CURRENT
kVA KILOVOLT AMPERE
kW KILOWATT
LBW LOAD BEARING WALL
MIN MINIMUM
(N) NEW
NEUT NEUTRAL
NTS NOT TO SCALE
OC ON CENTER
PL PROPERTY LINE
POI POINT OF INTERCONNECTION
PV PHOTOVOLTAIC
SCH SCHEDULE
S STAINLESS STEEL
STC STANDARD TESTING CONDITIONS
TYP TYPICAL
UPS UNINTERRUPTIBLE POWER SUPPLY
V VOLT
Vmp VOLTAGE AT MAX POWER
Voc VOLTAGE AT OPEN CIRCUIT
W WATT
3R NEMA 3R, RAINTIGHT
LICENSE
CA # 888104
C-10
MODULE GROUNDING METHOD: ZEP SOLAR I
AHJ: Diamond Bar
1. THIS SYSTEM IS GRID—INTERIIED VIA A
UL—LISTED POWER —CONDITIONING INVERTER.
2. THIS SYSTEM HAS NO BATTERIES, NO UPS.
3. A NATIONALLY —RECOGNIZED TESTING
LABORATORY SHALL LIST ALL EQUIPMENT IN
COMPLIANCE WITH ART. 110.3.
4. WHERE ALL TERMINALS OF THE DISCONNECTING
MEANS MAY BE ENERGIZED IN THE OPEN POSITION,
A SIGN WILL BE PROVIDED WARNING OF THE
HAZARDS PER ART. 690.17.
5. EACH UNGROUNDED CONDUCTOR OF THE
MULTIWIRE BRANCH CIRCUIT WILL BE IDENTIFIED BY
PHASE AND SYSTEM PER ART. 210.5.
6. CIRCUITS OVER 250V TO GROUND SHALL
COMPLY WITH ART. 250.97, 250.92(B).
7. DC CONDUCTORS EITHER DO NOT ENTER
BUILDING OR ARE RUN IN METALLIC RACEWAYS OR
ENCLOSURES TO THE FIRST ACCESSIBLE DC
DISCONNECTING MEANS PER ART. 690.31(E).
8. ALL WIRES SHALL BE PROVIDED WITH STRAIN
RELIEF AT ALL ENTRY INTO BOXES AS REQUIRED BY
UL LISTING.
9. MODULE FRAMES SHALL BE GROUNDED AT THE
UL—LISTED LOCATION PROVIDED BY THE
MANUFACTURER USING UL LISTED GROUNDING
HARDWARE.
10. MODULE FRAMES, RAIL, AND POSTS SHALL BE
BONDED WITH EQUIPMENT GROUND CONDUCTORS.
GENERAL NOTES
1. ALL WORK TO BE DONE TO THE 2013
CALIFORNIA BUILDING CODE, 2013 CALIFORNIA
PLUMBING CODE, AND THE 2013 CALIFORNIA
RESIDENTIAL CODE.
2. ALL ELECTRICAL WORK SHALL COMPLY WITH
THE 2011 NATIONAL ELECTRIC CODE AS AMENDED BY
THE 2013 CALIFORNIA ELECTRIC CODE.
UTILITY: Southern California Edison
CONFIDENTIAL — THE INFORMATION HEREIN
NUMBER: J B-91713011 00
CONTAINED SHALL NOT BE USED FOR THE
NTING SYSTEM:
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
Comp V4 w Flashing —Insert
[INVERTER:
PART TO OTHERS OUTSIDE THE RECIPIENTS
ULES:
ORGANIZATION, EXCEPT IN CONNECTION NTH
THE SALE AND USE OF THE RESPECTIVE
2) REC # REC260PEZ
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMIssION of soLARCITY INc.LAREDGE
# SE3000A—US—ZB—U
INTERIOR AND EXTERIOR CONDUIT ARE TO BE
PAINTED TO MATCH EXISTING PAINT
CONTRACTOR TO PROVIDE LADDER FOR ACCESS TO
ROOF FOR INSPECTION OF PANELS AND ROOF
MOUNTED SYSTEM.
0
PREMISE OWNER:
SHIRELY ZHAI
20445 GERNSIDE DR
WALNUT, CA 91789
APN: 8763-021-014
VICINITY MAP
Shirely Zhai RESIDENCE
3.12 KW PV ARRAY
PACE NAME:
COVER SHEET
CITY OF DIAMOND BAR
THESEPL NSAND "ARE
Al
♦ _
BY
JAN 19 7017
THE APPROVAL OF THESE PLANS SHALL NOT BE
CONSTRUED TO BE A PERBAIT FOR ANY VIOLATION
OF ANY CODE OR ORDINANCE OF THIS CFTY.
THESE PLANS SHALL BE ON THE JOB
FOR ALL REQUEST ED INSPECTIONS
INDEX
PV1 COVER SHEET
PV2 PROPERTY PLAN
PV3 SITE PLAN
PV4 STRUCTURAL VIEWS
PV5 -UPLIFT CALCULATIONS
PV6 THREE LINE DIAGRAM
PV7 ELECTRICAL CALCULATIONS
Cutsheets Attached
REV BY DATE COMMENTS
REV A I NAME DATE COMMENTS
ZAJLL?J * I * I * I *
DESIGN:
IHSAN Cankaya
SHEET: REV: DATE:
PV 1 12/23/2016
WO.SolarCity.
3055 Cleorview Way
San Mateo, CA 94402
T:(650) 638-1028 F:(650) 638-1029
(B88)—SOL—CITY (765-2489) www.solarcity.com
7
7'
I
127'
CONFIDENTIAL — THE INFORMATION HEREIN
JOB NUMBER: J g-91713011 00
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
MOUNTING SYSTEM:
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
ZS Comp V4 w Flashing —Insert
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
MODULES:
(12) REC # REC260PEZ
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
INVERTER:
PERMISSION OF SOLARCITY INC.
SOLAREDGE # SE3000A—US—ZB—U
SHIRELY ZHAI
20445 GERNSIDE DR
WALNUT, CA 91789
Shirely Zhai RESIDENCE
3.12 KW PV ARRAY
PACE NAME
PROPERTY PLAN
PROPERTY PLAN x
Scale:1" = 20'-0'
0 20' 40'
DESIGN:
IHSAN Cankaya i\`SolarCity.
T
3055 ClearAew Way
SHEET: REV DATE: Son Mateo, CA 94402
T:(650) 638-1026 F:(650) 638-1029
PV 2 12/23/2016 (888)—SOL—CITY (765-2489) www.solarcity.com
20445 Gemside Ur
MP1
PITCH: 29 ARRAY PITCH:29
AZIMUTH:129 ARRAY AZIMUTH: 129
MATERIAL: Comp Shinqle STORY: 1 Si
Digitally signed by Yong Heng
Yong Zbu
DN: dc=local, dc=SolarCity,
ou=SolarCity Users, ou=HQ,
He n g Zhu Date1hzh2016.12 25 11:10:10
-08,00,
I FC;FNr)
& WARNING LABELS
O (E) UTILITY METER & WARNING LABEL
Iav INVERTER W/ INTEGRATED DC DISCO
DC
29
SITE PLAR,
1
■ ,,;,. i:.. ,i.; ,;:... is
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: g-91713011 0 0
PREMISE OWNER: DESCRIPTION:
SHIRELY ZHAI Zhai RESIDENCE
DESIGN:
IHSAN Canka ya
`\,?'5olarCity.Shirely
�-
MOUNTING SYSTEM:
ZS Comp V4 w Flashing —Insert
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
SHALL IT BE DISCLOSED IN WHOLE OR IN
20445 GERNSIDE DR 3.12 KW PV ARRAY
w sNOR
��
PART TO OTHERS OUTSIDE THE RECIPIENTS
WALNUT, CA 91789
MODULES
(12) REC # REC260PEZ
3055 Mateo, CA Way
San Matteo, CA 94402
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
SHEET: REV: DATE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
SITE PLAN
PV 3 12/23/2016
T:(650) 638-1028 F:(650) 638-1029
(888)—SOL—CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE SE3000A—US—ZB—U
SIDE VIEW OF MP1 NTS
MP1
X-SPACING
X-CANTILEVER
Y-SPACING
Y-CANTILEVER
NOTES
LANDSCAPE
72"
24"
39"
O"
STAGGERED
PORTRAIT
48"
20"
65"
0"
RAFTER
2X8 @ 24" OC
ROOF AZI 129 PITCH 29 STORIES: 1
ARRAY AZI 129 PITCH 29
Comp Shingle - Skip Sheathing
X AND Y ARE ALWAYS RELATIVE TO THE STRUCTURE FRAMING THAT SUPPORTS THE PV.
X IS ACROSS RAFTERS AND Y IS ALONG RAFTERS.
PV MODULE
5/16"x1.5" BOLT WITH
5/16" FLAT WASHER
ZEP LEVELING FOOT
ZEP ARRAY SKIRT
ZEP MOUNTING BLOCK
ZEP FLASHING INSERT
(E) COMP. SHINGLE
(E) ROOF DECKING
5/16" DIA STAINLESS
STEEL LAG SCREW
(2-1/2" EMBED, MIN)
(E) RAFTER
INSTALLATION ORDER
LOCATE RAFTER, MARK HOLE
(1) LOCATION, AND DRILL PILOT
HOLE.
ATTACH FLASHING INSERT TO
(2) MOUNTING BLOCK AND ATTACH
TO RAFTER USING LAG SCREW.
INJECT SEALANT INTO FLASHING
(3) INSERT PORT, WHICH SPREADS
SEALANT EVENLY OVER THE
ROOF PENETRATION.
INSTALL LEVELING FOOT ON TOP
(4) OF MOUNTING BLOCK &
SECURELY FASTEN WITH BOLT.
CONFIDENTIAL —THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER:
J B-91713011 OO
PREMISE OWNER: DESCRIPTION:
SHIRELY ZHAI Shirely Zhai RESIDENCE
utbltr:
IHSAN Cankaya
��\
ftt
MOUNTNG SYSTEM:
ZS Comp V4 w Flashing -Insert
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
20445 GERNSIDE DR 3.12 KW PV ARRAY
'wou
;SolarCity.
PART TO OTHERS OUTSIDE THE RECIPIENTS
WALNUT CA 91789
MODULES
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
(12) REC # REC26OPEZ
3055 Clearview Way
San Mateo, CA 94402
SHEET: REV. DATE:
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
STRUCTURAL VIEWS
V 12 23 2016
/ /
T:(650) 638-1028 F:(650) 638-1029
(888)—SOL—CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE # SE3O0OA-US-ZB-U
UPLIFT CALCULATIONS
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOTCE USED FOR THE
JOB NUMBER: J B-91713011 0 0
rrctMix uNNtN: utwurnuN:
SHIRELY ZHAI Shirely Zhai RESIDENCE
�cNumm
IHSAN Cankaya
°`!'
MOUNTING SYSTEM:
ZS Comp V4 w Flashing —Insert
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,'
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
20445 GERNSIDE DR 3.12 KW PV ARRAY
WALNUT, CA 91789
�'���
►�� S�Ia���ty
MODULES:
(12) REC # REC260PEZ
3055 CIearview way
San Moteo, CA 94402
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME
UPLIFT CALCULATIONS
SHEET: REV. DATE:
PV 5 12/23/2016
T:(650) 638-1028 F:(650) 638-1029
(bee)—SOL—CITY (765-2489) www.salarcity.com
INVERTER:
SOLAREDGE # SE3000A—US—ZB—U
BOND (N) #8 GEC TO ONE (E) UFER AND I Panel Number:JA112CY
ONE (N) WATER BOND AT PANEL WITH Meter Number: 222010-893926
IRREVERSIBLE CRIMP Underground Service Entrance
E 125A CENTER —FED MAIN SERVICE PANEL
E 10OA/2P MAIN CIRCUIT BREAKER
10OA/2P
(E) LOADS
DC Ungrounded HNV
1 ) SOLAREDGE ## SE3000A—US—ZB—U LABEL: A
Inverter; 3000W, 240V, 97.59.; w/Unifed Disco and ZB, AFCI
20A/2P
-- —— — — — — ——
_ I
� B I
I
I
N
I
I
— — — EGCIGEC _
II y — — — GEC -
TO 120/240V
SINGLE PHASE
UTILITY SERVICE i
I
CITY of 01AIVIoND BAR
THESE P N A ��T� LS
I
J>,N 97017
THE APPROVAL. OF THESE PLANS SHALL NOT BE
CONSTRUED TO B= A PERMIT FOR ANY V10LATION
OF ANY CODE OR ORDINANCE OF THIS CrrY.
THESE PL aN S SHALL BE ON THE JOB
FOR ALL R: -JESTED iNSPECTIONS
Voc* = MAX VOC AT MIN TEMP
P0I (1)MURRAY a MP 020 PV ACKFEED BREAKER
Breaker, 20AYP-20A/2P-20A%1P, 2 Spaces, Quad
m
m
e
--——————————————— — — — — — —
GEC
Inverter 1
SOLAREDGE
SE3000A—US—ZB—U
240V
---LN
— (12)REC # REC260PEZ
PV Module; 260W, 236.6W PTC, MC4, 40mm, Black Frame, ZEP Enabled
Voc: 37.8 Vpmox: 30.7
Isc AND Imp ARE SHOWN IN THE DC STRINGS IDENTIFIER
SQUARE D
RoofTop Disconnect
10
z A i _
TcDc
3a DC- I MP 1: 1x12
GC— — — — — — — — — — — — — —— -- ————— —--————— ——— — — —— EGC——— ——————— —————---J
AC (1)SQUARED HU361DS
Disconnect; 30A, 600V, Non Fusible, NEMA 4X, 3 Wire
(1)ZEBo# 8 0-1459-001
PV (12)SOLAREDGE ! P300-5NM4ZS D� I
PowerBox ptimizer;30OW, ZEP, in MC4,out MC4
O
(1 )AWG #10, THWN-2, Black
(1 )AWG 0, THWN-2, Red
Qt
O
(1 ) AWG #10, THWN-2, Black
� (I)AWG 10, THNN-2, White
( i
Voc* = 500 VDC Isc = 15
Vm = 350 VDC Im — 8.8
P P—
ADC
ADC
O
g
(2) AWG g10, PV wire, 60OV, Black
(I)AWG 10, THHN W?d-2, Green
() # /TM
Voc* = 500
EGC Vm = 350
P
VDC Isc = 15 ADC
P=
VDC Im 8.8 ADC
(1)AWG #10, THWN-2, White
NEUTRAL Vmp =240 VAC Imp=12,5 AAC
(1)AWG /10, 1HWN-2,.Green .EGC, ..
,-(1),Conduit. Kit;.3/4'.EMT.........
.......
(1)Conduit Kit;, 3/4'.EMT............................
. ......... .
.......
-(1 )AWG g8,.THWN72,. Green
EGC/GEC-(1)Conduit Kit;.3/4'.EMT..........
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER: lJ g-91713011 00
PREMISE OWNER: DESCRIPTION:
SHIRELY ZHAI Shirely Zhai RESIDENCE
DESIGN:
IHSAN Cankayo
SSolarCi "
MOUNTING SYSTEM:
ZS Comp V4 w Flashing —Insert
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
20445 GERNSIDE DR 3.12 KW PV ARRAY
wo l+.�/
►��
PART TO OTHERS OUTSIDE THE RECIPIENTS
WALNUT, C A 91789
MODULES
(12) REC # REC260PEZ
3oss clear"°" way
San Mateo, CA 94402
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
SHEET: REV: DATE:
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME:
THREE LINE DIAGRAM
PV 6 12/23/2016
T:(650) 638-1028 F:(650) 638-1029
(888)—SOL-CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE # SE3000A—US—ZB—U
ELECTRICAL CALCULATIONS
CONFIDENTIAL — THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
PART TO OTHERS OUTSIDE THE RECIPIENTS
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
JOB NUMBER: J B-91713011
MOUNTING SYSTEM:
ZS Comp V4 w Flashing —Insert
MODULES:
(12) REC # REC260PEZ
INVERTER:
String and 2 Combined Strings
Module Type: Module Count:
REC 260PEZ 12
Branch Circuit Parallel MPPT
1 strings per Branch A
12 modules per series string
String
Conductor:
Icont' 1.25 = (Amps)
15
30 deg C ampacity =
40
PV Wire Size:
AWG #10
Icont = (Amps)
15
Start ampacity
40
Temperature derate (%=F)
0.76
Conduit fill derate (%=#)
1
Derated ampacity
30.4
Icont' 1.25 = (Amps)
15
Ampacitv
40
Inverter Output
Inverter Type: Inverter Count:
SolarEdge 3000 AFCI 1
Icont * 1.25 = (Amps)
15.62
OCP Size =
20
Conductor 3: AWG #10
THWN-2
Icont' 1.25 = (Amps)
15.62
30 deg C ampacity =
40
Icont = (Amps)
12.5
Start ampacity
40
Temperature derate (%=F)
0.91
Conduit fill derate (%=#)
1
Derated ampacity
36.4
Icont' 1.25 = (Amps)
15.62
Ampacitv
35
00
PREMISE OWNER:
SHIRELY ZHAI
20445 GERNSIDE DR
WALNUT, CA 91789
SOLAREDGE # SE3000A—US—ZB—U
Icont = (Amps):
15
strings per Branch B
modules per series string
Branch A Branch B
Conductor: Conductor:
18.75
40
AWG #10
15
40
0.76
1
30.4
18.75
40
Total
Icont = (Amps):
12.5
DESCRIPTION:
Shirely Zhai RESIDENCE
3.12 KW PV ARRAY
PACE NAME:
ELECTRICAL CALCULATIONS
IHSAN Cankaya
SHEET: REV: DATE:
PV 7 12/23/2016
.%SolarCity
3055 ClecNew Way
San Mateo, CA 94402
T:(650) 638-1028 F:(650) 638-1029
(888)—SOL—CITY (765-2489) www.solarcity.com
CAUTION
POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE
FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN:
- Address: 20445 Gernside Dr
DC
DISCONNECT
INVERTER AND
DC DISCONNECT
UTILITY
SERVICE
r--------------------
------�
SOLAR PHOTOVOLTAIC ARRAYS)
L---------------------------I
PHOTOVOLTAIC BACK —FED CIRCUIT BREAKER IN MAIN ELECTRICAL PANEL
IS AN A/C DISCONNECT PER NEC 690.17
OPERATING VOLTAGE = 240V
JB-91713011-00
CONFIDENTIAL -THE INFORMATION HEREIN
CONTAINED SHALL NOT BE USED FOR THE
JOB NUMBER:
J B-91713011 00
PREMISE OWNER: DESCRIPTION:
SHIRELY ZHAI Shirely Zhai RESIDENCE
DESIGN:
IHSAN Cankaya
N\f+ w
��
MOUNTING SYSTEM:
ZS Comp V4 w Flashing —Insert
BENEFIT OF ANYONE EXCEPT SOLARCITY INC.,
NOR SHALL IT BE DISCLOSED IN WHOLE OR IN
20445 GERNSIDE DR 3.12 KW PV ARRAY
����� Y•
r,`�Old1 {.y
PART TO OTHERS OUTSIDE THE RECIPIENTS
WALNUTCA 91789
MODULES
ORGANIZATION, EXCEPT IN CONNECTION WITH
THE SALE AND USE OF THE RESPECTIVE
(12) REC # REC260PEZ
,
3055 CleaNew Way
San Mateo, CA 94a02
SHEET: REV: DATE:
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN
PERMISSION OF SOLARCITY INC.
PAGE NAME
SITE PLAN PLACARD
PV 8 12/23/2016
T:(650) 638-1028 F:(650) 638-1029
(B88)-SOL-CITY (765-2489) www.solarcity.com
INVERTER:
SOLAREDGE # SE3000A-US-ZB-U
Label Location:
(C)(IC)(CB)
Per Code:
CRC R331.2
Label Location:
(DC) (INV)
Per Code:
CEC 690.14.C.2
Label Location:
(DC) (INV)
Per Code:
CEC 690.53
Label Location:
(DC) (CB)
Per Code:
CEC 690.17
Label Location:
(INV)
Per Code.-
CEC 690.5(C)
Label Location:
(AC) (POI)
Per Code:
CEC 690.14.C.2
Label Location:
(AC) (POI)
Per Code:
CEC 690.54
Label Location:
(AC)
Label Location:
(DC)
Per Code:
CEC 690.17
Label Location:
(POI)
Per Code:
CEC 705.12.D.7
Label Location:
(POI)
Per Code:
CEC 690.54; CEC 690.17
Label Location:
(D) (POI)
Per Code:
CEC 690.64.B.4
Label Location:
(POI)
Per Code:
CEC 705.12.D.7
Label Location:
(DC)(INV)(CB)
Per Code:
CEC 690.35(F)
TO BE USED WHEN
INVERTER IS
UNGROUNDED
(AC): AC Disconnect
(C): Conduit
(CB): Combiner Box
(D): Distribution Panel
(DC): DC Disconnect
(IC): Interior Run Conduit
(INV): Inverter With Integrated DC Disconnect
(LC): Load Center
(M): Utility Meter
(POI): Point of Interconnection
CONFIDENTIAL - THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR `%olop 0
af 3055 Clearview Way
THE BENEFIT OF ANYONE EXCEPT SOLARCITY INC., NOR SHALL IT BE DISCLOSED .9- San Mateo, CA 94402
IN WHOLE OR IN PART TO OTHERS OUTSIDE THE RECIPIENTS ORGANIZATION, Label Set ���� T:(650) 638-1028 F:(650) 638-1029
EXCEPT IN CONNECTION WITH THE SALE AND USE OF THE RESPECTIVE I� �Of ��'�� (888)-SOL-Cm (765-2489)www.solarcity.com
SOLARCITY EQUIPMENT, WITHOUT THE WRITTEN PERMISSION OF SOLARCITY INC.
_ 65.55 _0.I _
1.38 39.02
9 47.24
047 w a
�- IU
1
t
All measurements in inches
Nominal Power -P_(Wp) 2bU
Watt Class Sorting-(Wp) +/- 5
Nominal Power Voltage -V,,IV) 30.7
Nominal Power Current- 1_(A) 6.50
Open Circuit Voltage -Ve, (V) 37.8
Short Circuit Current- IX (A) 9.01
Panel E fficiency (%) 15.8
The electrical characteristics are within +/-10% of the indicated values ofl,,,V. and Pa„ at standard Test condition, (STC).
Values at standard test conditions STC (aurnass AM 1.5, inadiance 1000 W/m', cell temperature 777 (25'CU.
At law irradiance of 200 W/m' (AM 1.5 & cell temperature 77'F (2S'Q at least 97%of the STC panel efficiency will be achieved.
ELECTRICAL r.TA@ NrREC260PEZ
Nominal Power- P_(Wp) 197
Nominal Power Voltage -Vv, IV) 29.0
Nominal Power Current- IMPe (A) 6.81
Open Circuit Voltage- Vor (V) 35.7
Short Circuit Current- Isc (A) 7.24
Nominal oper acing cell temperatur e NOCT (800 W/m', AM 1.5, windspeed I ni/s, ambient temperature 687 (20'C1.
10 year product warranty.
,@us 25year linear power outputwarranty
LISTED (max. degression in performance of 0.7%p.a.).
UL 1703. Fire rating. Type I, Class C
EFFICIENCY
�O
YEAR PRODUCT WARRANTY
�j�
YEAR LINEAR POWER
�2//
OUTPUT WARRANTY
zTY»FREE
US IMPORT DUTY FREE
Nominal Operating Cell Temperature(NOCT)
45.70C(m2°C)
Temperature Coefficient ofP_
-0.40%/`C
Temperature Coefficient ofV°c
-0.27%/°C
Temperature Coefficient of Isc
0.024 %/'C
Cell Type:
60 REC PE multi -crystalline
3 strings of 20 cells with bypass diodes
Glass:
0.125 in solarglass with anti -reflection
surface treatment
Back Sheet:
Double layer highly resistant polyester
Frame:
Anodizedaluminum (black)
Zep Groove compatible
Junction Box:
IP67 rated
0.156 in (12 AWG) solar cable, 2 x 47.24 in
Connectors:
H4 Amphenol
Origin:
Made in Singapore
Operational Temperature:
Maximum System Voltage:
Design Load:
Max Series Fuse Rating:
Max Reverse Current:
-40...+185°F (-40...+85°C)
1000 V UL
SOlbs/ft'(2400 Pa)longside
30lbs/ft2 (1436 Pa) short side
lS A
15A
MECHANICAL DATA
Dimensions: 65.55 x 39.02 x 1.57 in (1665 x 991 x 40 mm)
Area: 17.75 ft2(1.65 m2)
Weight: 43Ibs(19.5kg)
Note! All given specifications are subject to change z
without notice at any time.
REC is a leading global provider of solar energy solutions. With more than 15 years of experience, we offer sustainable, high performing
products, services and investments for the solar industry. Together with our partners, we create value by providing solutions that better
meet the world's growing energy needs. REC is headquartered in Norway and listed on the Oslo Stock Exchange (ticker: RECSOL). Ourl,600
employees worldwide generated revenues of LSD 647 million in 2013.
REC
www.recgroup.com
r
solar =ee :.
SolarEdge Single Phase Inverters
For North America
SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US /
SE760OA-US / SE1000OA-US / SE1140OA-US
i
e
0
The best choice for SolarEdge enabled systems
Integrated arc fault protection (Type 1) for NEC 2011 690.11 compliance
I
Superior efficiency (98%)
Small, lightweight and easy to install on provided bracket
Built-in module -level monitoring
Internet connection through Ethernet or Wireless
Outdoor and indoor installation
Fixed voltage inverter, DC/AC conversion only
Pre -assembled Safety Switch for faster installation
Optional — revenue grade data, ANSI C12.1
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - ISRAEL www.solaredge.us
solar=@s Single Phase Inverters for North America
SE3000A-US / SE3800A-US / SE5000A-US / SE6000A-US /
SE7600A-US/SE10000A-US/SE11400A-US
SE3000A-US SE3800A-US SESOOOA-US SE6000A-US SE760OA-US SE10000A-US SE11400A-US
OUTPUT
Nominal AC Power Output
3000
3800
5000
9980 @ 208V
6000 7600 11400
VA
................. 30000.@ 240y ........I .....................
Max. AC Power Output
3300
3300
4150
5400 @ 208V
6000 8350 11180110 209V 12000
VA
.......... ..rOut .........................
.....................
5450 .@ A4Qy..
. .............. ................. 10950 @ 240V . .............................
AC Output Voltage Min.-Nom.-Max 14-
183 - 208 - 229 Vac
AC Output Voltage Min.-Nom: Max 10
J
211 - 240 - 264 Vac
I... ......................... I ........ i..................
...
...........................................
AC Frequency Min: Nom: Max.11l
................
............................................
59.3
- 60 - 60.5 (with
HI country setting 57 - 60 - 60.5)
..............
Hz
Max. Continuous Output Current
.....................................................
12.5
16
„I..,-..
,25..,,.., I.......3?......, .._4A @, A40V...1. _..,_ 47.5 ,
A
GFDI Threshold
1
A
................................................................................................................................................................................
Utility Monitoring, Islanding Protection, Country Configurable Thresholds Yes
Yes
INPUT
Maximum DC Power(STC)
4050 5100 6750 8100 10250 13500 15350
...............................................................................................................................
W
.........................
Transformer -less, Ungrounded
..........................R........................................
Yes
.................................................................. ............ ............................
..Max. Input Voltage.................................................................I..............500
.....................................................................
Vdc....
Nom. DC Input Voltage
..... .......
325 @ 208V / 350 @ 240V
................ .......... .............
Vdc
Max. Input Current
9.5 13
@20q �..1
I 23.......I.
I...
...........................................
... ..... .I 15.5 @ 240V ...18 .... 3035 .......34.5..... ....Adc....
Max. Short Circuit Current
........................
45 .........................................................
. Adc
.Input
.................
Reverse PolarltYProtection
Yes
Ground -Fault Isolation Detection
600ko Sensitivity
Maximum Inverter Efficiency
.........................................................
97.7 98.2 98.3 98.3 98 98 98 . ..........
].I.............I...................................................................... ...........
,G
. a
CEC Weighted Efficiency
97.5 @ 208V 97 @ 208V
I...... 97..
.................... ....................97
....... ......98......I.. 9$.@. 240y............ ... ..... 97..........97,5 @. A40V.. ............
....
Nighttime Power Consumption
<2.5 <4
W
ADDITIONAL FEATURES
Supported Communication Interfaces
..... ...... . ..... .. ............
RS485, RS232, Ethernet, ZigBee (optional)
......................i............... ..... ........... ...................
.........
Revenue Grade Data, ANSI C12.1
Optional'
Rapid Shutdown — NEC 2014 690.12
Functionality enabled when SolarEdge rapid shutdown kit is installed °
STANDARD COMPLIANCE
Safe[y....... ............................
........................................UL1741, UL1699B, UL1998, CSA 22.2
..........................................................................................
G.rid.Connection Standards
IEEE1547
... .......................................................................................................
Emissions
FCC a........................................................I...........
rt15 class B
INSTALLATION SPECIFICATIONS
AC output conduit size /AWG range
3/4" minimum / 16-6 AWG 3/4" minimum / 8-3 AWG
DC input conduit size / fi of strings /
3/4" minimum / 1-2 strings /
3 4" minimum / 1-2 strings 16-6 AWG
AWG,range..............................................................................................................................
14-6 AWG ........................
Dimensions with Safety Switch
30.5 x 12.5 x 10.5 /
in /
,(HxWxD).,.......,. ........................................................................................................................................................
30.5 x 12.5 x 7.2 / 775 x 315 x 184
775x315x260
mm
Weight with SafetyS............ ....
..........512/23.2..........I,............. _....54:7/24.7__................ -_....,,..._88.4/.40.1 ....--.......lb/.kg.
Natural
convection
Cooling
Natural Convection and internal Fans (user replaceable)
fan (user
..............................................................................................................
.re laceable
I Noise
.............................................................
............................. < 25 < 50
dBA
I Min: Max. Operating Temperature
-13 to +140 / 25 to +60 (40 to+60 version availabletsl)
'F /'C
Ran a
..... g.....................................
................................................................................................
Protection Rating ............................
,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, NEMA 3R
........................................................................
IsI For other regional settings please contact SolarEdge
support.
pl A higher current source may be used; the inverter
will limit its input current to the values stated.
pl Revenue grade inverter P/N: SExxxxA-USOOONNR2
(for 760OW inverter:5E7600A-U5002NNR2).
I°I Rapid shutdown kit P/N: SHD00-RSD-Sl.
IsI 40 version P/N: SExxx-USODONNU4 (for 760OW
imerter.5E7600A-U5002NNU4).
solar=@@
solar=@@SolarEdge
Power Optimizer -Zep CompatibleT""
Module Add -On For North America P300-ZEP
SolarEdge Power Optimizer —
P300-ZEP (for 60-cell PV modules)
,J
T'"
Zep CompatibleModule Add -On
INPUT
Rated Input DC power°I
...............................................................................................................................................................
300
W
Absolute Maximum Input Voltage (Voc at lowest temperature)
48
Vdc
For North America P300-ZEP
.......I ......... ................................. .........
MPPTOperatingRange
............. Operating gRan..............................................................................
.....................................
8-48
.........
Vdc
Maximum Short Circuit Current (Isc)
10
Ad[
....................................................................................................................................
Maximum DC Input Current
.......................................................................................................................................................
12.5
.......
Adc
Maximum Efficiency
...............................................................................
99.5
.......................................................................................I
%
..... ...
Wei hted Efficient
98.8
.... %.......
Overvoltage Category
II
OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING INVERTER)
Maximum Output Current
15
Adc
Maximum Output Voltage
60
Vdc
OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF)
b_
Safety Output Voltage per Power Optimizer 1
Vdc
`
STANDARD COMPLIANCE
EMC
FCC Part15 Class B, IEC61000-6 2, IEC61000 6 3
....................
............
•.
......................................................
Safety
IEC62109 1 (class II safety) UL1741
RoHS
Yes
INSTALLATION SPECIFICATIONS
• e
Maximum Allowed System Voltage
................ ............. ...............................
1000 ....................................
. Vdc
Dimensions including mounting bracket (W x L x H)
141 x 256 x 40.5 / 5.55 x 10.08 x 1.59
mm / in
..........
of 25�
�SdY 8
Wa
..........................................................................................................................................................
Dimensions excluding mounting bracket (W x L x H)
141 x 212 x 40.5 / 5.55 x 8.34 x 1.59
........................................
mm / in
...........
m Pt
y�•
Weight (including cables and mounting bracket)
1170 / 2.54
...................................................................................
kg / lb
..............................
Input Connector
MC4 / Amphenol / Tyco
...................................... ..............................
..............
...............................................................................
Output Connector
..................................................................................................................................
Double Insulated; Amphenol .............................
......
........
Output Wire Length
................................................................................................95......................................................
.95 0/ 3.0
m . ft
Operating Temperature Range
......... 40 - +85 / -40 - +185
'C /'F
Nor
Protection Rating...........................................................................
...... IP65 / NEMA4..... .... ........................
..............
..Relative Humidity................................................................................................100.............I............................
%......
of Rated STC power of the module. Module of up to t5%power tolerance allowed..
Compatible with Zep Groove framed modules
i
— Certified Zep CompatibleTM bracket
— Attaches to module frame without screws - reduces on -roof
labor and mounting costs
— Power optimizer equipment grounded through the bracket
— Up to 25% more energy
— Superior efficiency (99.5%)
— Mitigates all types of module mismatch losses, from
manufacturing tolerance to partial shading
— Flexible system design for maximum space utilization
— Next generation maintenance with module -level monitoring
— Module -level voltage shutdown for installer and firefighter
safety
USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us
PV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE THREE PHASE THREE PHASE
208V 480V
Minimum String Length (Power Optimizers)
8 10 18
.
.....................................................................................................I.............................
Maximum String Length (Power Optimizers)
25 25 50 ......................
................................................................................................................................................
Maximum...P.o.wer...per...Strin..g
.............................................................................
5250 6000 12.750
W
Parallel Strings of Different Lengths or Orientations
Yes
"" solar i
�
�
December 24, 2016
RE:
Project/Job # 91713011
Project Address:
AHJ
SC Office
Design Criteria:
CERTIFICATION LETTER
Zhai Residence
20445 Gernside Dr
Walnut, CA 91789
Diamond Bar
City of Industry
- Applicable Codes = 2013 CBC, ASCE 7-10, and 2012 NDS
- Risk Category = II
- Wind Speed = 110 mph, Exposure Category C, Partially/Fully Enclosed Method
- Ground/Roof Snow Load = 0 psf
- MP1-LOWER: 2x8 @ 24" OC, Roof DL = 14 psf, Roof LL = 17.5 psf
- MP1-UPPER: 2x8 @ 24" OC, Roof DL = 14 psf, Roof LL = 17.5 psf
Per Section 1613.1, W-(PV)/ W-(exist roof) = 4.5%, Increase Seismic Shear Load < 10%, -> [OK]
To Whom It May Concern,
Version #64.8 - TBD
Yong
Digitally signed by Yong Heng
Z u
DN: dc=local, dc=5olarCity,
ou=5olarCity Users, ou=11Q,
Heng h
cmail=01612
Z u
of
1 ci 9co:55 -08'00'
A jobsite survey of the existing framing system of the address indicated above was performed by a site survey team from SolarCity.
Structural evaluation was based on site observations and the design criteria listed above.
Based on this evaluation, I certify that the existing structure directly supporting the PV system is adequate to withstand all loading
indicated in the design criteria above based on the requirements of the applicable existing building and/or new building provisions
adopted/referenced above.
Additionally, I certify that the PV module assembly including all standoffs supporting it have been reviewed to be in accordance with the
manufacturer's specifications and to meet and/or exceed all requirements set forth by the referenced codes for loading.
The PV assembly hardware specifications are contained in the plans/dots submitted for approval.
3055 Clearview Way San Mateo, CA 94402 'r (650) 638 - 1028 (888) SOL - CITY ,. (6501 638 - 1029 soiarcity.com
.`L 0560-,-%; rd•a�I-Z M C?:3','�Fii. -< .. CO Ecaf,41�N 10C C,63. all LC CIQW5. DC=tJG1:W.L)tiv.,'n...:.. _2-9`, :: _C 15207 --n� - � .;C:>_, R EIXOO`-2 .. i (;i Z^7?n. _ if-OJU 11A Kii'tEbE!2�
EL-'1,3:tq,M rt .1:.9At6 i'NC:t, t7i:3iRG .. J.,,1 ;,.,: t3N.,'.::U':"};+5Ub.9l,aEB3i':,9r'C�.:t•:°E:N3i, Sail tP/:'V?C�l'135'.. .. �: d- =.-6. R C:'D?. OF CHWCO AfC5G2 ilp Mrp -
W� x
J iC
v' ,UR$1 3 iYC o27V " iW U.J p14 ,.1Q OOa.6:,: t t hhil i D I - y. t r„t lq. n!SrC IV yC I ry ..
t)s+v— SWI,,r& '>rnm ..r. mar e.<�sa :1. c.isnre r,l i:.,an.e Jrt ,Vvn.2 nrC �+eun, can l.icrm.�la, ..
u e.r n, ,.��.+4 .t.t..r,i.._1. i.K<r,t., tHtlnmrtr e+^=Jr".3t��U.f..p::sr.k•s.�.:i.r„n<^OSC',,,�J':i<..f �r.i.<I _,i;:r k47Gh
��, 9
�a��QSo�r�it
y
Version #64.8 - TBD
HARDWARE DESIGN AND STRUCTURAL ANALYSIS RESULTS SUMMARY TABLES
Landscape
Hardware
Hardware - Landscape Modules' Standoff Specifications
X-X Spacing
X-X Cantilever
Y-Y Spacing
Y-Y Cantilever
Configuration
Uplift DCR
MP3-LOWER
72"
24"
39"
NA
Staggered
39.8%
MPi-UPPER
72"
24"
39"
NA
Staggered
39.8%
I
Portrait
Hardware
Hardware - Portrait Modules' Standoff Specifications
X-X Spacing
X-X Cantilever
Y-Y Spacing
Y-Y Cantilever
Configuration
Uplift DCR
MPi-LOWER
48"
201'
65"
NA
Staggered
44.2%
MP3-UPPER
48"
20"
65"
NA
Staggered
44.2%
Structure
Mounting Plane Framing
Qualification Results
Type
Spacing
Pitch
Member Evaluation Results
MP3-LOWER
Vaulted Ceiling
24" O.C.
290
Member Impact Check OK
MP3-UPPER
Vaulted Ceiling
24" O.C.
290
Member Impact Check OK
Refer to the submitted drawings for details of information collected during a site survey. All member analysis and/or evaluation is based on framing information
gathered on site. The existing gravity and lateral load carrying members were evaluated in accordance with the IBC and the IEBC.
3055 Clearview Way San Mateo, CA 94402 : (b50) 638 - 1028 (888) SOL - CITY r (650) 638 - 1029 solarcity.com
�,,, a, .. •0'37. A: .171!/Ro.`C-0J, CA CS.G Will. f;8frq�.(IIIC O.}.,1,:8EL,C1.1.,.�U3..v4�^.i.C.JJVO�_�,..�.:;U5,OE 20ht'.02�,.^:'1-dA;7 tt C.+,...;,.cb. 11 Cr1.731,.
6 1,1, --k.:..G/r hll6:e ;�...s3. U
J. Y`, iJ;'i 4 l 7 F 77-f ..,�.,�c si/eU, Ji r 1i ➢JJt r w a nJ9"tnry a 1 r i as aA of or,
EI 4hIt 1 1;, 11WX rt.L.�-
;,!:• —Id . ....Cix.(f
:01014. PI 1.1 r,.,:I.J.F-017,1!'il.hPt.x ,#cic4
:SEISMIC CONSIDERATIONS
'---------------------'---' ---�---------|
_seismic sigh Criteria (per USGS)
ALTERATION LATERAL DESIGN 10% EXCEPTION CHECK
Weight of Proposed PV System
ALTERATION LATERAL DESIGN 10% EXCEPTION CHECK
Weight of Proposed PV System
-Area-
Dead Load
Weight
Weight of Roof on Existing Building
Portion,of Roof Weight
Area
Dead Load
Weight
Interior Walls (Too Half)
396 sf
5.0 psf
1,982 lbs
,Net Weight of Roof Under PV
W(exist)
13,947 lbs
Check4O/o Increase of Roof Weight / Seismic Shear Load
% Increase of DCR of Lateral
Force Resisting System
W(PV)/ W(exist)
I
4.5%
I Increase Seismic Shear Load < 10%, > [0K]
IBC Sect. 3404.4
Note: Seismic base shear is directly proportional to roof weight.
,STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK - MP1-LOWER
Member Properties Summary
MP1-LOWER
Horizontal Member Spans
Rafter Properties _
Overhang
3.16 ft
Actual W
1.50"
Roof System Pro erties
San 1
14.72 ft
Actual D
7.25"
Number of Spans w/o Overhang)
2
Span 2
2.61 ft
Nominal
Yes
Ro , ofing Material
Comp Roof
San 3
A in^2
10.88
Re -',Roof
No
Span 4
Sx (in .A3)
13.14
PI 'wood Sheathing
Yes
San 5
Ix in^4
47.63
Board Sheathing
Skip -Sheathing
Total Rake Span
23.43 ft
TL Defl'n Limit
180
Vaulted Ceiling
Yes
PV 1 Start
12.42 ft
Wood Species
DF
Ceiling Finish
1/2" Gypsum Board
PV 1 End
17.80 ft
Wood Grade
#2
Rafter Slope
290
PV 2 Start
Fb (psi)
900
Rafter Spacing
24" O.C.
PV 2 End
Fv (psi)
180
TOO Lat Bracing
Full
PV 3 Start
E(psi)
1,600,000
Bot Lat Bracing
Full
PV 3 End
E-min(psi)
580,000
Member Loading Summary
Roof Pitch
7 12
Initial
Pitch Adjust
Non-PV Areas
PV Areas
Roof Dead Load
DL
14.0 psf
x 1.14
16.0 psf
16.0 psf
PV Dead Load
PV-DL
3.0 psf
x 1.14
3.4 psf
Roof Live Load
RLL
20.0 psf
x 0.88
17.5 psf
Live/Snow Load
LL/SLla
Total Load(Governing LC
TL
1
1 33.5 psf
1 19.4 psf
Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (IS) py ; Ce=0.9, Ct=1.1, 15=1.0
Member Design Summary (per NDS)
Governing Load Comb
I CL +
CL -
CF
Cr
D + Lr
1.25
1 1.00
1 1.00
1 1.2
1.15
Member Analysis Results Summa
Governing Analysis
Pre-PV Moment
lb -in)
JPost-PVMomentJ
Net Im act
Result
Gravity Loading Check
-1340
1 -1036 1
1 0.77
Pass
I;ZEP HARDWARE -DESIGN CAL_CULATIONS MP1 LOWER
Mountinq' Plane Information c
Roofing 'Material •
Comp Roof
I
Roof Slope
Rafter Spacing
290
24 O.C.
Framing Type / Direction
PV,System Type
Zep System_Type.. _ _._.... _
Standoff Attachment Hardware
_ _
Y-Y Rafters
Solarbty SleekMountTM
..._ _ _ _ ----__-_ _.- _ ___- _.._ _-_ -_ -___
ZS Comp
Como Mount SRV
- _ -___ -_-_ _ ._.
Spanning Vents
No
Wind iDesi n Criteria
Wind Design Code
IBC 2012
ASCE 7-10
Wind Design Method , _
Partially/Fully Enclosed Method
Ultimate Wind Speed
V-Ult
_ 4i110 mph _
1609A
Exposure_Category_ -_._-_
_ __
__.. _
_ C -
_._Fig.
Section 26.7
Roof Style
__.._ _ _- -=
Gable Roof
_ .
Fig. 30.4-2A/B/C-5A/B
Mean Roof Height
h
15 ft
Section 26.2
Wind Pressure Calculation Coefficients
Wind Pressure Exposure
KZ
0.85
Table 30.3-1
Topographic Factor
Kt
1.00
Section 26.8
Wind Directionality Factor
0.85
Section 26.6-1
Im ortance Factor
_Kd -
I
_ __.-._._. . NA..__
Velocity Pressure
qh
qh = 0.00256 (Kz) (Kzt) (Kd) (V^2)
Equation 30.3-1
22.4 psf
Ext. Pressure Coefficient U
GCp (Up)
-0.95
Fig. 30.4-2A/B/C-5A/B
Ext. Pressure Coefficient Down
GCp Down
0.88
Fig.30.4-2A/B/C-5A/B
Design Wind Pressure
p
p = qh (GCp)
Equation 30.4-1
Wind Pressure Up
-21.3 psf
Wind Pressure Down
19.6 psf
'ALLOWABLE STANDOFF SPACINGS
X-Direction
Y-Direction "
Max Allowable Standoff Spacing
Portrait
48"
65"
,Max Allowable_ Cantilever ..,
_........Portrait.._..._.
�___.. _. ...... 20 "
NA
Standoff Confi uration
Portrait
Staggered
Max Standoff Tributary Area
Trib
22 sf"
PV Assembly Dead Load
W-PV
3.0 psf
Net Wind Uplift at Standoff
T-actual
-242 Ibs _
Uplift_Capacity of Standoff
T-allow
548 Ibs
Standoff Demand/Capacity
DCR
44.2%
STRUCTURE ANALYSIS - LOADING SUMMARY AND MEMBER CHECK -.MP1-UPPER
Member Properties Summary
MP1-UPPER
Horizontal Member Spans
Rafter Properties
Overhang
Actual W
1.50"
Roof System Properties
Span 1
10.07 ft
Actual D
7.25"
Number of Spans (w/o Overhang)
1
Span 2
Nominal
Yes
Roofing Material
Comp Roof
Span 3
A (in^ 2)
10.88
Re -Roof
No
Span 4
Sx (in.A3)
13.14
PlVwood Sheathing
Yes
Span 5
Ix (inA4)
47.63
Board Sheathing
Skip -Sheathing
Total Rake Span
11.51 ft
TL Deffn Limit
180
Vaulted Ceiling
Yes
PV 1 Start
Wood Species
DF
Ceiling Finish
1/2" Gypsum Board
PV 1 End
6.50 ft
Wood Grade
#2
Rafter Slope
290
PV 2 Start
Fb (psi)
900
Rafter Spacing
24" O.C.
PV 2 End
Fv (psi)
180
Top Lat Bracing
Full
PV 3 Start
E (psi)
1,600,000
Bot Lat Bracing
Full
PV 3 End
E-min (psi)
580,000
I Member Loading Summary
Roof Pitch
7/12
Initial
Pitch Adjust
Non-PV Areas
PV Areas
Roof Dead Load
DL
14.0 psf
x 1.14
16.0 psf
16.0 psf
PV, Dead Load
PV-DL
3.0 psf
x 1.14
3.4 psf
Roof Live Load
RLL
20.0 psf
x 0.88
17.5 psf
I Live/Snow Load
LL/SL 1,2
ITotal Load (Governing LC
TL
16.0 psf
19.4 psf
Notes: 1. ps = Cs*pf; Cs -roof, Cs -pv per ASCE 7 [Figure 7-2] 2. pf = 0.7 (Ce) (Ct) (I,) pg ; Ce=0.% Ct= 1. 1, is-- 1.0
Member Design Summaryper NDS)
Governing Load Comb
CD
CL
CL
CF
Cr
D
0.9
1.00
1 1.00
1 1.2
1 1.15
Member Analysis Results Summary
I Governing Analysis
Pre-PV Moment
(lb -in)
Post-PV Moment�
Net Impact
Result
Gravity Loading Check
776
431
1 0.56
PA-M
2EP HARDWARE DESIGN CALCULATIONS _M„P1-UPPER_
Wind Desi nCriteria
Wind Design Code IBC 2012 ASCE 7-10
Wind Design Method _ _ -__ _- _ _ - Partially/Fully Enclosed Method
_ __—
Ultimate Wind Speed V-Ult 110 mph Fig. 1609A
Exposure Category_ _____ C . _ _ _ _ _ Section 26.7__
Roof Style Gable Roof Fig 30.4-2A/B/C-5A/B
Mean Roof Height h 15 ft Section 26.2
WindPressure Calculation -Coefficients
Wind Pressure Exposure
KZ
0.85
Table 30.3-1
Topographic Factor
KZt
1 00
Section 26.8
Wind Directionality Factor
Kd
0.85
Section 26 6-1
Importance Factor
I
NA
Velocity Pressure
qh
qh = 0.00256 (Kz) (Kzt) (Kd) (V^2)
Equation 30.3-1
22.4 psf
Wind Pressure
Ext. Pressure Coefficient U
GCp (Up)
-0.95
Fig. 30.4-2A/B/C-5A/B
Ext. Pressure Coefficient Down
GC Down
0.88
Fig. 30.4-2A/B/C-5q/B'
Design Wind Pressure
P
p = qh (GCp)
Equation 30.4-1
Wind Pressure Up
Nup)-21.3
psf
Wind Pressure Down
19.6 psf
,ALLOWABLE STANDOFF SPACINGS-_
X-Direction, ,, .
Y,-Direction
Max Allowable Standoff Spacing
Portrait
48"
65'
Max Allowable Cantilever_.__
Standoff figuration
Portrait
Staggered
Max; Standoff Tributary Area_'`
_. _
� Trib
_ .. 225f._. .._..__�._..._ ... ..-._.
___..._ .__...
PV Assembly Dead Load
Net Wind -Uplift; at Standoff
W-PV
_ _ T-actual
3.0 psf
_ _ - -242 Ibs
Uplift Capacity of Standoff
Standoff Demand/Capacity
T-allow
DCR
548 Ibs
44.2%