HomeMy WebLinkAboutPR16-1118D WAV BAR
CITY OF DIAMOND BAR
DEPARTMENT OF COMMUNITY &DEVELOPMENT SERVICES
21810 Copley Drive, Diamond Bar, CA 91765 PRESS
(909) 839-7020 Fax: (909) 861-3117 Building Inspection Hotline (909) 839-7027 FIRMLY
BUILDING PERMIT APPLICATION www.cityofdiamondbar.com building@diamondbarca.gov
JOB SITE ADDRESS 1I '� 20 jb.;Uo
APN LOT�� TRACT
OWNER Ra /Liwil r f eL ft D %iA
ADDRESS t 3 b lI AA
CITY 13 ZIP 41VJ TEL. Z
APPLICANT era %i2A,,, t.t.J TEL. l e -7 3 S` -7
CONTRACTOR
ADDRESS N l b 5fr &.' Id ex , d a!rc
CITY 1" r>. -pr Y� ZIP '15 .� TEL. AJ7/ tAO
ARCH/ENG/
DESIGNER
ADDRESS
CITY ZIP TEL.
OWNER -BUILDER DECLARATION
I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the reason(s)
indicated below by the checkmark(s), I have placed next to the applicable item(s) [Section 7031.5, Business and
Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair, any
structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she
is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9) Commencing with Section
7000 of Division 3 of the Business and Professions Code] or that he or she is exempt from licensure and the basis for
the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty
of not more than five hundred dollars ($500).
U 1, as owner of the property, or my employees with wages as their sole compensation, will do U all of or U portions
of the work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The
Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds
or improves the property, provided that the improvements are not intended or offered for sale. If however, the building or
improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built
or improved for the purpose of sale.).
U I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section
7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who
builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State
License Law.).
U I am exempt from licensure under the Contractor's State License law for the following reason(s):
By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one
year prior to completion of the improvements covered by this permit,) cannot legally sell a structure that I have built as an
owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the
applicable law, Section 7044 of the Business and Professions Code is available upon request when this application is
submitted or at.the following Web site: http/www.leginfo,ca.gov/calaw,html.
LICENSED CONTRACTOR'S DECLARATION
I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000)
of Division 3 of the Business and Professions Code, and my license is in full force and effect.
LICENSE CLASS: 9- SID LIC. NO.: '774 Z Dq
DATE: r4t4 CONTRACTOR:
WORKER'S COMPEfRSATIONJ4ECLARATION
I HEREBY AFFIRM UNDER PENALTY OF PERJURY ONE OF THE FOLLOWING DECLARATIONS:
I have and will maintain a Certificate of Consent to Self -Insure for Worker's Compensation, as provided by
Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
I have and will maintain Worker's Compensation Insurance, as required by Section 3700 of the Labor Code, for
the performance of the work for which this permit is issued. My Worker's Compensation Insurance Carrier and
Policy Number are
CARRIER
POLICY NUMBER 4Y YIj
THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS).
I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to
become subject to the Worker's Compensation Laws of California. And agree that if I should become subject to the Worker's
Compensate n pmvisions of Section 3700 of the Labor Code, I shall forthwith comply with those provisions.
DATE: �APPLICANT:
7+,///
WARNING: Failure to secure Worker's Comp�Yhrage is unlawful, and shall�s lect an employer to criminal
penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of the compensation,
damages as provided for in section 3708 of the labor code, interest, and attorney's fees.
CONSTRUCTION LENDING AGENCY
I hereby affirm under penalty of perjury that there is a Construction Lending Agency for the performance of the work for
which this permit is issued (Sec. 3097, Civ. C.).
LENDER'S NAME:
LENDER'S ADDRESS:
I certify that I have read this application and state that the above information is correct. I agree to comply with all city and
county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to
enter upon the above-mentioned property for inspection purposes.
1? V tZi�I✓��.t
PERMITTEE NAME (PRIN 01
SIGNATURE OF PER �E DATE
APPLICATION DATE: `
ISSUE DATE:Jn
TYPE CONST. /kC&
P/C#
//hr
OCC GROUP: ';f
Scope of Work U C n a
# DWEL. UNITS If ST
n "1'C A
r JJ
DESCRIPTION SQ. FT. FACTOR PSF
ADJ. AREA/VALUATION
SFR/ADD/REM
Garage/Carport
LU
Patio/Deck
LU
u-
Pool/Spa
ZRe
-Roof
Commercial
DO
DO
Valuation:
Adj. Area:
QUANTITY DESCRIPTION FEE
U
Q
U
J
W
co
z
m
J
rl
r-
93
U
CONSTRUCTION:
PLAN REVIEW:
ELECTRIC:
PLUMBING:
MECHANICAL:
hili L'%
INSPECTION FEE:
ISSUANCE:
SMIP:
ENERGY P/C:
ENERGY PERMIT:
RETENTION FEE:
PRE -ALT FEE:
y�G
BASF:
PLOT PLAN:
ZONING CLEARANCE:
TOTAL FEES
COMMENTS:
AM,
P/C: q PAID BY: yy VALIDATION:
RECEIPT # PAID BY: VALIDATION
WHITE — Department Copy, YELLOW — Finance Copy, PINK — Assessor Copy
CITY OF DIAMOND BAR
IJ INSPECTION RECORD
INSPECTION DATE INSPECTOR
SETBACK/ LETTER
FOOTINGS FORMS
SLAB
UG. PLUMBING
UG. ELECTRI ' x ` `•,r! p'
UFER GROU r..'" "' yr
SEWER LATERALU4 LLT: s 4� �r , 9
, :' !s
MAIN WATER LIN C0
SEWER CLEANOUT
ROOF SHEATHING
FLOOR SHEATHING
SHEAR WALLS EXTERIOR
SHEAR WALLS INTERIOR
FRAMINGNENTING
ROUGH MECHANICAL
ROUGH ELECTRICAL W( ) C ( )
ROUGH PLUMBING
INSULATION WALL
INSULATION CEILING
DRYWALL
LATH (PRE)
LATH EXTERIOR
LATH INTERIOR
GAS TEST
SCRATCH COAT
ELECTRIC METER RELEASE
GAS METER RELEASE
SPECIAL INSPECTION
FINAL BUILDING
FINAL MECHANICAL AAW r,
FINAL ELECTRICAL
FINAL PLUMBING
T.C. of OCCUPANCY
CERT. of OCCUPANCY
COMMENTS:
INSPECTION DATE
O.
TRACT AND LEDGER
SWITCH GEAR
COMMERCIAL HOOD
T -BAR
INTERCEPTER
HOT MOP/SHOWERPAN
SEPTIC/CESSPOOL
HERS REPORT RECEIVED q /
DEMOLITION
ROOF DRAINS
ROUGH CONDUIT
POOUSPA
ROUGH PLUMBING
ROUGH ELECTRICAL
ROUGH MECHANICAL
GAS TEST
PRE GUNITE
POOL PRE DECK BONDING
P -TRAP
FENCE / GATE/ ALARM
FINAL POOL
WALLS:
WALL FOOTING/STEEL
WALL STEEL 1sT( )2 ND( ) LIFT
WALL BOND BEAM
WALL DRAIN/ SEAL
WALL FINAL
R0. FRAMING PLANNING APPROVAL
ROUGH FIRE APPROVAL
FINAL FIRE DEPARTMENT
FINAL PLANNING
FINAL ENGINEERING/ PW
FINAL COMMUNITY SERVICES
FINAL HEALTH DEPT.
FINAL INDUSTRIAL WASTE
ALTERATIONS - HVAC
C=C CF1R-ALT-04=E �,Reysed 06114:: CALI-CRl71A ENERGY CG:LIF:AISS'ON
CERT!F1CATE QP CO!V1PLIP.NCE
CHR-ALTAM-E
lterat ans -HVAC CZ 2, and 8-15 ;formerly CF -IR -ALT -HVAC) (Page 1 of 1)
! _ .-,.•:y- --_.
form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site.
�. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final:
All Equipment,
CFIR-ALT-02-E
Condenser Unit, Evaporator Coil,
13 jr—
110
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS', MECH-25-HEP,S'
Air Handler/Furnace' (Can include new ducting)
or
Installer Requirement: Duct leakage L15%, or < 10% to outside, or seal all accessible leaks), Air Flow >: 300 CFM/ten, Refrigerant Charge.
Equipment Type
111. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or
Equipment Efficien cy
Refired R -value
! Floor Area (sq ft)
� T r:�r.� ostat
i
❑ ?ackaoed Sy—m0
yaporator Coil
condensing
I
! AFUE CO.
i ❑ R-6 (CZ 2, 8-13) rutting
I
Served by System
Setback
j (: natatready
! El split- System
I Unit
Cl
� (
11R-8' (211, 14', 15J Ducting,
qft
�
present, must
❑ Mini Split
E Compressor
I SEEP i HS -F
! ❑ R 6 (a;l 2's) Plenums
Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos
��
�
QFurnace
❑ Lineset
r Tv;;
i EER
! f
❑ R-5 or R7.-) L:neset'
' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25
ice irste,le�rJ i
HERS VERIFICATION SUMMARY Installer determines work to be completed and matches to one of the options belo-.u. At permit application this I
form is allowed to be filled out by hand. For final inspection all forms are to be registered (no hand filled forms allowed) and a copy left on site.
�. HVAC Changeout/Repair Required Compliance Documents to be left on site for Final:
All Equipment,
CFIR-ALT-02-E
Condenser Unit, Evaporator Coil,
CF2R: MECH-01, MECH-20-HERS, MECH-(23 or 24)' -HERS, MECH-25-HERS'
Compressor, TXV, Lineset,
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS', MECH-25-HEP,S'
Air Handler/Furnace' (Can include new ducting)
Installer Requirement: Duct leakage L15%, or < 10% to outside, or seal all accessible leaks), Air Flow >: 300 CFM/ten, Refrigerant Charge.
Exempted from duct leakage testing if:
111. Duct system registered with HERS provider as previously sealed, or ❑ 2. There is less than 40 linear feet of duct in unconditioned space, or
113. Existing duct systems are constructed, insulated or sealed with asbestos (list manufacture date of building
112. New HVAC System Required Compliance Documents to be left on site for Final
All new equipment and All New Ducts'
CF111-ALT-02-E
including Mini Split
CF2R: MECH-01, MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERS2
CF3R: MECH-20-HERS, MECH-22-HERS, MECH-(23 or 24) -HERS', MECH-25-HERSZ
Mini Splits require CFIR-ALT-02-E, CF2R-MECH-01, and (CF2R-CF3R) MECH-25-HERS
Installer Requirement Duct leakage < 6%, Fan Efficacy (.58W/CFM), Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge _
❑ 3. All New Ducts with Replacement Y
Required Compliance Documents to be left on site for Final.
All New Ducts' and one or more of the following
CFIR-ALT-02-E
replaced: Condenser Unit, Evaporator Coil,
CF2R: MECH-01, PAECH-20-HERS, PAECH-(23 or 24) -HERS, MECH-25-HERS
Compressor, TXV, Lineset, Furnace'
CF3R: MECH-20-HERS, MECH-(23 or 24) -HERS, MECH-25-HERS
Installer Requirement: Duct leakage < 6%, Air Flow >_ 350 CFM/ton (or alternative), Refrigerant Charge
Exempted from duct leakage testing if: ❑ 1. Existing duct systems are constructed, insulated or sealed with asbestos
��
❑ 4. New Ducting over 40 feet Required Compliance Documents to be left on site for Final
New ducting but less than All New Ducts' CFIR-ALT-02-E CF2R: MIECH-20 HERS, CF3R: MECH 20 -HERS
Installer Required to: Duct leakage (S_15% or, < 10% to outside or, or seal all accessible leaks)
❑ EXCEPTION: Existing duct systems constructed, insulated or sealed with asbestos.
'All new ducting R-8 required when more than 40 ft installed and R-6 when less than 40 ft installed. This includes in walls, between floors etc.
' Heating only systems and Air Handler/Furnace changes do not require Air Flow MECH-(23 or 24), or Refrigerant Charge verification MECH-25
3 All New Ducts is when at least 75 percent of the duct system is new duct material, and up to 25 percent may consist of reused parts from the
dwelling unit's existing duct system (e.g., registers, grilles, boots, air handler, coil, plenums, duct material)
R-5 W' thick insulation) for linesets 1" and less. R-7.5 (1.5" thick insulation) for linesets over 1 inch. Most mfg will require Suction line Diameter
with insulation as the following 1.5-2T-2%", 2.5-3T-2%", 3.5 to 4T-2%', 5T-4%"
Contractor t-Docasrentation Author's /Responsible Designer's Declaration Statement)
1 certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Compliance is true and correct
2. 1 am eligible under Division 3 of the California Business and Professions Code to accept responsibility for the information on this document.
3. That the energy features and performance specifications for the design identified on this Certificate of Compliance conform to the
requirements of Title 24, Parts 1 and 6 of the California Code of Regulations (CCR).
4. That the energy features and performance specifications, materials, components, and manufactured devices for the building design or
system design identified on this Certificate of Compliance conform to the requirements of Title 24, Part 1 and Part 6 of the CCR.
5. The building design features or system design features identified on this Certificate of Compliance are consistent with the information
i provided on other applicable compliance documents, worksheets, calculations, plans and specifications submitted to the enforcement
i agency for approval with this building permit application.
Responsible Designer Name:
Responsible Designer Signature:
Date Signed: License:
Company:
Ad ss:
G y%State/L'p:
Phone:
co i
•�
y
/
For assistance or questions regarding the Energy 5tandaros, contact the tnergy novme ar: i-avu-1 is—V-
CERTIFICATE OF VERIFICATION
CF3R-MCH-20-H
Duct Leakage Diagnostic Test
(Page 1 of 3 )
Project Name: BONNIE PALLOTTA
Enforcement Agency: City of
Diamond Bar
Permit Number:
pr161118
Dwelling Address: 1435 ROLLING KNOLL
ROAD
City: Diamond Bar
Zip Code:
91765
A. System Information
01
Space Conditioning System Identification or Name
System 1
02
Space Conditioning System Location or Area Served
Location 1
03
Building Type from CF -1R
Single family
04
Verified Low Leakage Ducts in Conditioned Space
No, credit is not taken
05
(VLLDCS) Credit from CF1R?
Total leakage
05
Verified Low Leakage Air Handling Unit Credit from
No, credit is not taken
07
CF1R?
Cooling system method
06
X34 ,
Duct System Compliance CategoryQF
Alteration
09
Calculated Target Allowable Duct Leakage Rate (cfm)
300
. y ....
MCH -20d - Complete Replacement or AlteredDuct`System - -
B. Duct Leakage Diagnostic Test
01
Condenser Nominal Cooling Capacity (ton)
5
02
Heating Capacity (kBtu/h)
0
03
Conditioned Floor Area served by this HVAC system (ft2)
2300
04
Duct Leakage Test Condition
Test final
05
Duct Leakage Test Method
Total leakage
06
Leakage Factor
0.15
07
Air Handling Unit Airflow (AHUAirflow) Determination
Method
Cooling system method
08
Measured AHUAirflow
This field or section is not applicable
09
Calculated Target Allowable Duct Leakage Rate (cfm)
300
10
Actual duct leakage rate from leakage test measurement
(cfm)
299
F-11
Compliance Statement: System passes leakage test
Registration Number: 216-A0165835A-M2000002A-M20A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:03
2013 Residential Compliance I Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 2 of 3 )
B. Duct Leakage Diagnostic Test
12 Notes:
C. Additional Requirements for Compliance
01
System was tested in its normal operation condition. No temporary taping allowed.
Outside air (OA) duct connections to the central forced air duct system shall not be sealed/taped off during duct leakage
testing. OA ducts used for Central Fan Integrated (CFI) Indoor Air Quality ventilation systems, or Central Fan Ventilation
02
Cooling Systems, that utilize dampers that open only when OA is required and automatically close when OA is not required,
may configure the OA damper to the closed position during duct leakage testing.
03
If a complete replacement, all supply and return register boots were sealed to the drywall.
04
Building cavities were not used as plenums or platform returns in lieu of ducts.
05
If cloth backed tape was used it was covered with Mastic and draw bands.
06
All connection, points between the air handler and the supply and return plenums are completely sealed.
,,.....
If the system complies using the Smoke;Test method tWsmoke test was conducted in accordance with the requirements
07
of Reference Residential Appendix RA3'1.4 3 6 Systems that comply using smoke test shallnot be included in'sample
groups for HERS verification compliance: � . V-� _
08
Verification Status -
lare mete ---
ss - all applicable requirements
PP
09
Correction Notes for this table
The responsible persons signature on this compliance document affirms that all applicable requirements in this table have
been met unless otherwise noted in the Verification Status and the Corrections Notes in this table.
D. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 I Complies: All specified verification protocol requirements on this document are met.
Registration Number: 216-A0165835A-M2000002A-M20A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:03
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-20-H
Duct Leakage Diagnostic Test (Page 3 of 3 )
Documentation Author's Declaration Statement
1.1 certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �
Ian Jacoby
can dacobJt
Company:
Date Signed:
i PERMIT E RATERS
2016-05-31 10:23:42
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive #213
City/State/Zip:
Phone:
West Lake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Verification is true and correct.
2. 1 am the certified HERS Rater• who performed the verification identified and reported on this Certificate of verification (responsible rater).
3. The installed features,.materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified on the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applicable sections`'the Certifica2e(s) of Installationi(CF212) signed and sutimitte'd3'by the person(s) responsible for the
construction or installation conforms to the requirements specified on the Cert ficate(s) of Compliance (CF,1R) approved by,,the enforcement agency.
&de.available �
5. 1 will ensure thata registered copy of this Certificate of Verification shall be posted or s with he�building permit(s ssued for the
applieab�le I'unde and`that a registered, copy of this;Certificate of
building, and made available to the,enforcement atatgency,for all inspections
Verification is required to be'jncluded with the documenion the bwlderprovides to the building owner at occupancy.
Of
Builder Or Installer Information As Shown On'The"'Certificate Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
W C HEATING & AIR CONDITIONING INC
Responsible Builder or Installer Name:
CSLB License:
Rusty Cochran
779604
HERS Provider Data Registry Information
Sample Group Number (if applicable):
Dwelling Test Status in Sample Group (if applicable)
Tested
HERS Rater Information
HERS Rater Company Name:
i PERMIT E RATERS
Responsible Rater Name:
Responsible Rater Signature:
Richard Douthit
Responsible Rater Certification Number w/ this HERS Provider:
Date Signed:
CC2006570
2016-05-31 11:20:46
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 216-A0165835A-M2000002A-M20A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:03
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION
CF3R-MCH-23-H
Space Conditioning System Airflow Rate
(Page 1 of 4 )
Project Name: BONNIE PALLOTTA
Enforcement Agency: City of
Diamond Bar
Permit Number:
pr161118
Dwelling Address: 1435 ROLLING KNOLL
ROAD
City: Diamond Bar
Zip Code:
91765
A. Ducted Cooling System Information
01
System Identification or Name
System 1
02
System Location or Area Served
Location 1
03
System Installation Type
Alteration
04
Nominal Cooling Capacity (tons) of Condenser
5
05
Condenser Speed Type. ;';
Single Speed
06
Cooling System Zonal Control Type
Not Zonal
07
Central Fan Integrated (CFI) Ventilation System Status..
Not a CFI syste4W SIFF20,m
08
System Bypass Duct Status`
NoBypassDuct
09
Date of System Airflow Rate"Weasurement x
2016.05-25 -
t; .
10
Airflow Rate Protocol utilized w
� fir... � �. ��._..�
RA3.3 procedures for airflow rate measurement
B. Hole for the placement of a Static Pressure Probe (HSPP), and Permanently installed Static Pressure Probe (PSPP)
in the supply plenum.
Procedures for installing HSPP or PSPP are specified in RA3.3.1.1.
01 Method used to demonstrate compliance with the HSPP installed and labeled consistent with Figure RA3.3-1
HSPP/PSPP requirement
C. Airflow Rate Measurement Apparatus and Procedure Information
Instrument Specifications are given in RA3.3.1.1, and system airflow rate measurement apparatus information is given
in RA3.3.2.
Airflow Rate Measurement Type used for this airflow rate
Traditional Flow Capture Hood according to procedure in
01
verification.
RA3.3.3.1.4
02
Manufacturer of Airflow Measurement Apparatus
ALNOR
03
Model number of Airflow Measurement Apparatus
EBT731
Certification Status of the Airflow Measurement Apparatus
Certified by Manufacturer and listed on CEC Website at
04
Accuracy
http://www.energy.ca.gov/title24/equipment—cert/ama—fas
/index.html
Registration Number: 216-A0165835A-M2300002A-M23A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:42
2013 Residential Compliance Schema Version: 0.555SDD
CERTIFICATE.OF VERIFICATION CF3R-MCH-23-H
Space Conditioning System Airflow Rate (Page 2 of 4 )
MCH -23a Forced Air System Airflow Rate Measurement - Newly Installed Non -Zoned Systems or Zoned Multi -Speed
Compressor
D. Forced Air System Airflow Rate Measurement
The procedures for System Airflow Rate Verification are specified in Reference Residential Appendix RA3.3.
01
Required Minimum System Airflow Rate (cfm/ton)
300
02
Required Minimum System Airflow Target (cfm)
1500
03
Actual System Airflow Rate Measurement (cfm)
1769
04
Compliance Statement:
System airflow rate complies
E. Additional Requirements
Air filters that meet the applicable requirements of.Standards Section 150.0(m)12 or 150.0(m)13 were properly installed in
01
the system during system air flow rate measurement identified on this Certificate of Verification.
The airflow rate measurement apparatus used to performAhe airflow rate measurement�identified on th&Cert3ificatAf
02
Verification was calibrated in accordance with the apparat6s manufacturer's specif cations and conformso the
instrumentation specifications given in RAS 3 1.3' Arm
A visual inspection shall confirm that bypass ducts that d liver conditioned supply air directly to the space conditioning
system return duct airflow are not used on newly constructed zonally controlled systems unless the Performance Certificate
03
of Compliance indicates an allowance for use of a bypass duct. When a bypass duct is accounted for on the Performance
Certificate of Compliance, the airflow rate shall conform to the specifications listed on the Certificate of Compliance.
04
All registers were fully open during the diagnostic test.
05
System fan was set at maximum speed during the diagnostic test.
06
If fresh air duct is part of the HVAC system it was not closed during the diagnostic test.
07
Airflow rate and fan watt draw shall be simultaneous measurements when used to calculate the Fan Efficacy tested value.
Multi -speed compressor space cooling systems or variable speed compressor systems shall verify air flow (cfm/ton) and fan
08
efficacy (Watt/cfm) with system operating in cooling mode at the maximum compressor speed and the maximum air.
handler fan speed.
09
Verification Status
Pass - all applicable requirements are met
10
Correction Notes
The responsible person's signature on this compliance document affirms that all applicable requirements in this table have
been met unless otherwise noted in the Verification Status and the Corrections Notes in this table.
Registration Number: 216-A0165835A-M2300002A-M23A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:42
2013 Residential Compliance Schema Version: 0.555SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-23-H
Space Conditioning System Airflow Rate (Page 3 of 4 )
F. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
01 I Complies: All specified verification protocol requirements on this document are met.
Registration Number: 216-A0165835A-M2300002A-M23A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:42
2013 Residential Compliance Schema Version: 0.555SDD
CERTIFICATE OF VERIFICATION CF3R-MCH-23-H
Space Conditioning System Airflow Rate (Page 4 of 4 )
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �/ �
Ian Jacoby
cyan daeobI
Company:
Date Signed:
i PERMIT E RATERS
2016-05-31 10:23:42
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive #213
City/State/Zip:
Phone:
West Lake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Verification is true and correct.
2. 1 am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3. The installed features; materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified Ion this Certificate of Verification comply with the.applicable requirements in Reference Appendices RA2, RA3, and the requirements
specifiedon, the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applica11 b 11 le sectionsf"the Certificates) of Installati11 on ( CUR I)rsigned and sUbmitted''by the per responsible for the
�iw .1 1 � !W, ,
construction or installation conforms to the r'equirements�specified= the Certificates) of Compliance (CF1R) approved by the enforcementmgency.
5. 1 will ensure that -a registered copy of this Certificate of Verificatiowshall be posted or mad ailable with the building permits) issued for the
building, and made available to the enforcement agency for all applicable inspections. I unde rstand.that a registeredicopy of,thKCertificate.of
r o
" w ri - 'R. _ .k $ 4�da'�` .l P
Verification is required to be included with the documentation the builder provides to the building owner at occupancy.
_...
Builder Or Installer Information As Shown bn'The Certificate""Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
W C HEATING & AIR CONDITIONING INC
Responsible Builder or Installer Name:
CSLB License:
Rusty Cochran
779604
HERS Provider Data Registry Information
Sample Group Number (if applicable):
Dwelling Test Status in Sample Group (if applicable)
Tested
HERS Rater Information
HERS Rater Company Name:
i PERMIT E RATERS
Responsible Rater Name:
Responsible Rater Signature:
/
Richard Douthit
`�Ci�^�,,�,,/ `
Responsible Rater Certification Number w/ this HERS Provider:
Date Signed:
CC2006570
2016-05-31 11:20:46
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 216-A0165835A-M2300002A-M23A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:22:42
2013 Residential Compliance Schema Version: 0.555SDD
a ! 0."
CERTIFICATE OF VERIFICATION
CF3R-MCH-25-H
Refrigerant Charge Verification
(Page 1 of 4 )
Project Name: BONNIE PALLOTTA
Enforcement Agency: City of
Diamond Bar
Permit Number:
pr161118
Dwelling Address: 1435 ROLLING KNOLL
ROAD
City: Diamond Bar
Zip Code:
91765
A. System Information
HERS Rater to field -verify all system information, discrepancies to be noted by overwriting entry.
01
System Identification or Name
System 1
02
System Location or Area Served
Location 1
03
Condenser (or package unit) make or brand
LENNOX
04
Condenser (or package unit) model number
XC16-060-230-05
05
Nominal Cooling Capacity (tons) of Condenser
5
06
Condenser (or package unit) serial number ,
5815LO1987
07
Refrigerant Type
R-410A*t
08
Other Refrigerant Type (if6applicable) _ :"V"-,
1�k
44.5%
09
System Installation Type,Alteratiori
,
Charge Indicator Display (CID) Status (Note: Even systems
This system does not have a CID device installed
10
with a CID must have refrigerant charge verified by installer).
Is the system of a type that the minimum airflow can be
Yes, this is a ducted system and one of the system airflow
11
verified using an approved measurement procedure (RA3.3
rate measurement procedures in RA3.3 or RA3.2.2.7 can be
or RA3.2.2.7)?
used to verify system airflow rate requirements.
Is the system of a type that approved refrigerant charge
Yes, one of the Refrigerant charge verification procedures
verification procedures can be used to verify compliance
from RA3.2.2 or RAI is applicable to this system and can be
12
with the refrigerant charge verification requirements when
used to verify compliance
temperatures are greater than or equal to 55F (RA3.2.2, or
RAI)?
13
Date of Refrigerant Charge Verification for this system
2016-05-25
Refrigerant charge verification method used.
Subcooling (outdoor temperature must be equal to or
14
greater than 55 degF)
Person who performed the Refrigerant Charge Verification
HERS rater
15
reported on this Certificate of Installation
16
HERS Verification Compliance Requirement Status
System does not qualify for group sampling
17
Refrigerant charge verification method used by HERS Rater.
Subcool
Registration Number: 216-A0165835A-M2500002A-M25A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:23:14
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-25-H
Refrigerant Charge Verification (Page 2 of 4 )
MCH25b - Refrigerant Charge Verification - Subcooling Method
B. Metering Device Verification - HERS Rater is required to visually field verify all information from CF2R
Subcooling Method can only be used on systems that have a variable metering device.
01
Refrigerant metering device
Thermostatic Expansion Valve (TXV)
02
Subcooling Method applicability status
Subcooling Method is applicable to this system.
C. Instrument Calibration - HERS Raters are required to calibrate their diagnostic tools.
Procedures for instrument calibration are given in Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01
Date of Digital Refrigerant Gauge Calibration
2016-05-01
02
Date of Digital Thermocouple Calibration
2016-05-01
03
Digital RefrigerantGauge Calibration Status
Calibration is current
04
Digital Thermocouple Calibration Status � 4 ,-
!-1CaliUr iici is currents ... �
„-
D. Measurement Access Hole (MAH) Verification -'HERS Raters"are required to visually:•fieldverify MAH
Procedures for installing MAH arespecifiedli,n,y eference Residential Appendix:RA3 2:2.3 R;
01 Method used to demonstrate compliance with the MAH installed and labeled consistent with Figure 3.2-1
Measurement Access Hole (MAH) requirement
E. Minimum System Airflow Rate Verification
Procedures for verifying minimum system airflow are specified in Reference Residential Appendix RA3.2.2.7.
01
Minimum Required System Airflow Rate (cfm)
1500
02
System Airflow Rate Verification Status
System complies with minimum airflow rate requirements
F. Data Collection - HERS Rater must independently collect all data in this section.
Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in
Reference Residential Appendix RA3.2.2 and RA3.2.2.2
01
Lowest return air dry bulb temperature that occurred during
73
the refrigerant charge verification procedure (degreeF)
Measured Condenser air entering dry-bulb temperature (T
71
02
condenser, db)
03
Outdoor Temperature Qualification Status
Outdoor temperature is within range for using Subcooling
refrigerant charge verification method
Registration Number: 216-A0165835A-M2500002A-M25A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:23:14
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-25-H
Refrigerant Charge Verification (Page 3 of 4 )
F. Data Collection - HERS Rater must independently collect all data in this section.
Procedures for determining Refrigerant Charge using the Standard Charge Verification Procedure are given in
Reference Residential Appendix RA3.2.2 and RA3.2.2.2
04
Measured Liquid Line Temperature (Tiiquid) (degree F)
74
05
Measured Liquid Line Pressure (PGgwd) (pisg)
241
06
Condenser saturation temperature (Tcondensor, Sat) from digital
81
gauge or P -T Table using Line F05 (degree F)
07
Measured Subcooling
7
08
Target Subcooling
7
04
Compliance Statement: System complies with Subcooling Method - Must also pass metering device verification, next
09
section
G. Metering Device: Verification
Procedures for the verification of proper metering device operation are specified in RA3.2.2.6.2
01
Measured Suction line temperature (T(degreeF)-
57r. DOWN
suction)
02
Measured Suction line prdssure'(Psuction) (ps)
'"103
Evaporator saturation temperature (Tevapo ato,,sat)Nfhom�
33
03
digital gauge or P -T Table using line G02 (degreeF)
04
Measured Superheat
24
05
Measured Superheat is between 3 and 26 deg F (inclusive)
Passes CEC requirement
Measured Superheat is within manufacturer's specifications,
Not known
06
if known
07
Compliance Statement: Metering device verification passes
H. Determination of HERS Verification Compliance
All applicable sections of this document shall indicate compliance with the specified verification protocol requirements in order
for this Certificate of Verification as a whole to be determined to be in compliance.
O1 1 Complies: All specified verification protocol requirements on this document are met.
Registration Number: 216-A0165835A-M2500002A-M25A Registration Date/Time: 2016-05-31 11:20:46 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:23:14
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF VERIFICATION CF3R-MCH-25-H
Refrigerant Charge Verification (Page 4 of 4 )
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Verification documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: �/ /'
Ian Jacoby
cyan dacobJt.
Company:
Date Signed:
i PERMIT E RATERS
2016-05-31 10:23:42
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive #213
City/State/Zip:
Phone:
West Lake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided'on this Certificate of Verification is true and correct.
2. 1 am the certified HERS Rater who performed the verification identified and reported on this Certificate of Verification (responsible rater).
3. The installed features, materials, components, manufactured devices, or system performance diagnostic results that require HERS verification
identified.on this Certificate of Verification comply with the applicable requirements in Reference Appendices RA2, RA3, and the requirements
specified'on the Certificate of Compliance for the building approved by the enforcement agency.
4. The information reported on applicable sections 1. of the Certificates) of,•,Installaiion`i(CF2R) signed`and.submittedlby the person(s) responsible for the
construction or installation conforms to the requiremenmspeci ec! n the Certificates) of Compliance (CF1Rapproved by he enforcement,agency.
11 -)
5. 1 will ensure that a registered copy,of this Certificate of verificationshall be posted; or made ayailabI6 with the,.building permit(s) issued for the
u,..
building, and made available to the,enforcemennt,agency for all applicable inspections. I nderstand that a registere6copy ofthi Certiflcaf of
Verification is required to be included with the documentation the builder provides to tiie building owner at occupahcy.
Builder Or Installer Information As Shown On The"Certificate"Of Installation
Company Name (Installing Subcontractor, General Contractor, or Builder/Owner):
W C HEATING & AIR CONDITIONING INC
Responsible Builder or Installer Name:
CSLB License:
Rusty Cochran
779604
HERS Provider Data Registry Information
Sample Group Number (if applicable):
Dwelling Test Status in Sample Group (if applicable)
Tested
HERS Rater Information
HERS Rater Company Name:
i PERMIT E RATERS
Responsible Rater Name:
Responsible Rater Signature:
(__ /�j) y.�
Richard Douthit
C�Ci;^� k/6'f`C��L(/
Responsible Rater Certification Number w/ this HERS Provider:
Date Signed:
CC2006570
2016-05-31 11:20:46
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider
responsibility for the accuracy of the information.
Registration Number: 216-A0165835A-M2500002A-M25A Registration DateTime: 2016-05-31 11:20:46 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:23:14
2013 Residential Compliance Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION
CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans
(Page 1 of 7 )
Project Name: BONNIE PALLOTTA
Enforcement Agency: City of Diamond Bar
Permit Number:
pr161118
Dwelling Address: 1435 ROLLING KNOLL ROAD
City: Diamond Bar
Zip Code:
91765
A. General Information
01
Dwelling Unit Name
BONNIE PALLOTTA
02
Climate Zone
9
03
Dwelling Unit Total Conditioned Floor
2300
04
Number of Space Conditioning
1
CFA served
Area (ft2)
Installing aInstalling
new SC
Systems in this Dwelling Unit.
Installing
05
Certificate of Compliance Type
Prescriptive alterations (CF1R-ALT)
06
Method used to Calculate HVAC Loads
NotApplicableEquipmentChangeout
07
Calculated Dwelling Unit Sensible
This field or section is not applicable
08
Calculated Dwelling Unit Heating Load
This field or section is not applicable
Name
Cooling Load (Btuh)
System (ftZ)
ducted
(gtuh )
components?
09
Dwelling Unit Number of Bedrooms
3
MCH -01b Prescriptive Alterations - Space Conditioning Systems Ducts nd Fans �=
B. Space Conditioning (SC) System Information E kr M
O1
02
03
04
05
06
07
08
09
10
SC System
SC System
CFA served
Is the SC
Installing aInstalling
new SC
Installing more
Installing
Installing
Identification or
Location or Area
by this SC
a
systemsystem
refrigerant
than 40 feet of
entirely new
entirely new SC
Alteration Type
Name
Served
System (ftZ)
ducted
containing
components?
ducts?
duct system?
system?
system.
component.
Altered space
System 1
Location 1
2300
Yes
Yes
Yes
No
No
No
conditioning
system
Registration Number: 216-A0165835A-M0100002A-0000
CA Building Energy Efficiency Standards - 2013 Residential Compliance
Registration Date/Time: 2016-05-31 10:21:37
Report Version: 2013 Rev 1.007
Schema Version: 2013.1.007
HERS Provider: CaICERTS
Report Generated: 2016-05-31 10:18:43
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 2 of 7 )
C. Space Conditioning (SC) System Alterations Compliance Information
01
02
03
04
05
06
07
08
09
10
it
12
13
Rated Heating Capacity,
Name
Heating Efficiency Type;
Value a
Manufacturer
Model Number
nu nber
Output (BTUH)
-oil*x,
-
_ a ? .- W
Central Fan
fir, a ,
System 1
AFUE
0.8
LENNOX �C-03
SL280UH090XV60
5915G27y7729
70
Notes:
Integrated
Heating
Cooling
New or
(CFI)
System
Altered
Heating
Minimum
Altered
Cooling
Minimum
Required
Replaced
New
Ventilation
Identification
Heating
Heating
Efficiency
Efficiency
Cooling
Cooling
Efficiency
Efficiency
Thermostat
Duct
Duct
System
or Name
System Type
Component
Type
Value
System Type
Components
Type
Value
Type
Length
R -Value
Status
All new
All new
System 1
Central gas
heating
AFUE
0.8
Central
cooling
SEER
16
Setback
LTE40Ft
R6
Not a CFI
furnace
componen
split AC
components
system
is
D. Installed Heating Equipment Information
01
02
_93
04-y„
05 _
06
07
System Identification or
1-161 ng Efficiency
t Heat ng^U
) Heating Unit
Heatin&Unit serial
Rated Heating Capacity,
Name
Heating Efficiency Type;
Value a
Manufacturer
Model Number
nu nber
Output (BTUH)
-oil*x,
-
_ a ? .- W
L
fir, a ,
System 1
AFUE
0.8
LENNOX �C-03
SL280UH090XV60
5915G27y7729
70
Notes:
Registration Number: 216-A0165835A-M0100002A-0000 Registration Date/Time: 2016-05-31 10:21:37 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016 -OS -31 10:18:43
Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 )
E. Installed Cooling Equipment information
01
02
03
04
05
06
07
08
Condenser or Package Unit
System Identification
or Name
Cooling Efficiency
Type
Cooling Efficiency
Value
Condenser or
Package Unit
Manufacturer
Condenser or
Package Unit
Model Number
Condenser or
Package Unit
Serial Number
System Rated Cooling
Capacity at Design
Conditions (BTUH)
Condenser Rated
Nominal Capacity
(ton)
System 1
SEER
16
LENNOX
XC16-0050-230-
58151-01987
60000
5
Notes:
H. Installed Air Filter Device Information
This section does not apply to this project.
I. Air Filter Device Requirements
This section does not apply to this project.
Registration Number: 216-A0165835A-M0100002A-0000
Registration Date/Time: 2016-05-31 10:21:37
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:18:43
Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 )
J. HERS Verification Requirements
01
02
03
04
05
06
07
08
09
10
MCH2O
MCH21
MCH22
MCH23
MCH25
MCH28
Exemption
from
Minimum
Exemption
R -Value for
AHU
System
SC System
From Duct
Duct
Ducts In
Ducts Located
AHU Fan
Airflow
Identification or
Location or Area
Leakage
Leakage
Conditioned
In Cond Space
Efficacy
Rate
Refrigerant
Return Duct Design
Name
Served
Requirements
Test
Space
Verification
(W/cfm)
(cfm/ton)
Charge
Table 150.0-C or D
System 1
Location 1
No
Yes
No
No
No
Yes
Yes
No
exemptions
Exemption
Notes:
Registration Number: 216-A0165835A-M0100002A-0000 Registration Date/Time: 2016-05-31 10:21:37 HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:18:43
Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Heating Equipment
Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency
01
Regulations.
Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant
02
to program the temperature set points for at least four different periods in 24 hours. See Sections 150.0(i), 110.2(b).
Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections
03
150.0(h)1 and 2).
Furnace Temperature Rise: Central forced -air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum
04
inlet -to -outlet temperature rise specification. See Section 150.0(h)4. .
05 Standby Losses and Pilot Lights: Fan -type central furnacesima of havea con—tin uouslyburning pilotAlightSe tion 110.5and Section 110.2(d).
6
'Aw
v
Cooling Equipment �
0
All rnbst'meet the°minimum efficiency requirements of Section 110.1 and Section 110'2(a) and the Appliance Efficiency
06
Equipment Efficiency: cooling equipment
Regulations.
Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R -value and protection requirements of Section
07
150.0(j)2 and 3, and Section 150.0(m)9.
08
Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A.
Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section
09
150.0(h)1 and 2.
Air Distribution System Ducts, Plenums and Fans
Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be
30
required by the prescriptive or performance requirements. See Section 150.0(m)1.
Registration Number: 216-A0165835A-M0100002A-0000
Registration Date/Time: 2016-05-31 10:21:37
HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:18:43
Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 )
K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures
Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the
system that are altered. Existing equipment may be exempt from these requirements.
Connections and Closures: All installed air -distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0,
602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply -air and return -air ducts and plenums must be insulated to a minimum installed level of R-6.0 or
11
enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference
Residential Appendix RA3.1.4.3.8.
Heat Pump Thermostat
12
A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c).
13
The thermostat shall be installed in accordance with the manufacturers published installation specifications
14
First stage of heating shall be assigned to heat pump heating.
15
Second stage back up heating shall be set to come.on only when the indoor set temperature cannot be met.
The responsible person signature on this compliance document affirms�': that all applicable;requirements in`this table have bepilien met.
Registration Number: 216-AO165835A-MO100002A-0000
.4T 4
Registration Date/Time: 2016-05-31 10:21:37
HERS Provider: CalCERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016 -OS -31 10:18:43
Schema Version: 2013.1.007
CERTIFICATE OF INSTALLATION CF2R-MCH-01-E
Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 )
Documentation Author's Declaration Statement
1. 1 certify that this Certificate of Installation documentation is accurate and complete.
Documentation Author Name:
Documentation Author Signature: ////
J,n
Jacoby, Ian
acoc
Company:
Signature Date:
i PERMIT E RATERS
2016-05-31 10:21:03
Address:
CEA/ HERS Certification Identification (if applicable):
31225 La Baya Drive #213
City/State/Zip:
Phone:
West Lake Village CA 91362
818-735-7876
Responsible Person's Declaration statement
I certify the following under penalty of perjury, under the laws of the State of California:
1. The information provided on this Certificate of Installation is true and carred.
2. 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials,
components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an
WK
authorized representative of the responsible builder/installer. _'
applicable the
3. The constructed or installed features, materials, components or mariufaduredidevices,(the installation) identified on this Certificate of Installation conforms to all codes and regulations, and
4- i4 a3, p as
by the agency.
installation conforms to the requirements given on the plans and specificationsapproved enforcement --
4. I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that-identifi the specific equirementsJor the scope oft, owjruction or iinstallation identified on this Certificate of
Installation, and I have ensured that the requiremethat apply to the construction or installation have been met.
nts
X7 #
g py,of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building and madeYavailable to the enforcement agency for all
5. I will ensure that a registered co
applicable inspections. I understand that a registered copy of this Certificate o?1nstallation is required to be included with the documentation the Builder p"i'ovides to the building owner at occupancy.
Responsible Builder/Installer Name:
Responsible Builder/Installer Signature: /�
eear�
Cochran, Rusty
Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)
Position With Company (Title):
W C HEATING & AIR CONDITIONING INC
EMPLOYEE
Address:
CSLB License:
25976 MADISON AVE
779604
City/State/Zip:
Phone:
Date Signed:
MURRIETA CA 92562
951-600-0700
2016-05-31 10:21:37
Digitally signed by CaICERTS. This digital signature is provided in order to secure the content of this registered document, and in noway implies Registration Provider responsibility for the accuracy of the information.
Registration Number: 216-A0165835A-M0100002A-0000 Registration Date/Time: 2016-05-31 10:21:37 HERS Provider: CaICERTS
CA Building Energy Efficiency Standards - 2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-05-31 10:18:43
Schema Version: 2013.1.007