Loading...
HomeMy WebLinkAboutPR16-0905C.TV OF DIAMOND BAR ^Rn,P i I DEPARTMENT OF COMM UNI`i-adtvEVELOPMENfkROCES 21810 Copley Drive, Diamond Bar, CA 91765 PRESS (909) 839-7020 Fax: (909) 861-3117 Building Inspection Hotline (909) 839-7027 FIRMLY BUILDING PERMIT APPLICATION www.cityofdiamondbar.com building@diamondbarca.gov JOB SITE ADDRESS 14 V6 %, Lv,r4rd &Jr APN T TRACT OWNER - ADDRESSIWO CITY ZIP APPLICA TEL. CONTRACTOR ADDRESS CITY YlP T ARCH/ENG/ DESIGNER ADDRESS r CITY IP TEL. OWNER- UIL ER D CLARATION I hereby affirm under penalty of perjury that I am exempt from the Contractor's State License Law for the reasons) indicated below by the checkmark(s), I have placed next to the applicable item(s) [Section 7031.5, Business and Professions Code: Any city or county that requires a permit to construct, alter, improve, demolish, or repair, any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractor's State License Law (Chapter 9) Commencing with Section 7000#�f Division 3 of the Business and Professions Code] or that he or she is exempt from licensure and the basis for the ati ged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of at more than five hundred dollars ($500). (_;'I, as owner of the property, or my employees with wages as their sole compensation, will do U all of or U portions Tithe work, and the structure is not intended or offered for sale (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who, through employees' or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale. If however, the building or improvement is sold within one year of completion, the Owner -Builder will have the burden of proving that it was not built or improved for the purpose of sale.). U I, as owner of the property, am exclusively contracting with licensed Contractors to construct the project (Section 7044, Business and Professions Code: The Contractors' State License Law does not apply to an owner of property who builds or improves thereon, and who contracts for the projects with a licensed Contractor pursuant to the Contractors' State License Law.). U I am exempt from licensure under the Contractor's State License law for the following reason(s): By my signature below I acknowledge that, except for my personal residence in which I must have resided for at least one year prior to completion of the improvements covered by this permiLl cannot legally sell a structure that I have built as an owner -builder if it has not been constructed in its entirety by licensed contractors. I understand that a copy of the applicable law, Section 7044 of the Business and Professions Code is available upon request when this application is submitted or at the following Web site: http/www.leginfo.ca.gov/calaw.html. LICENSED CONTRACTOR'S DECLARATION I hereby affirm under penalty of perjury that I am licensed under provisions of Chapter 9 (commencing with Section 7000) of Division 3 of the Business and Professions Code, and my lice a is in full force and effect. LICENSE C S: LIC. NO.: q DATE: CONTRACTOR: WORKER'S COMPEN ATION DECLARATION I HEREBY AFFIRM UNDER PENALTY OF PERJURY ONE OF THE FOLLOWING DECLARATIONS: I have and will maintain a Certificate of Consent to Self -Insure for Worker's Compensation, as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. I have and will maintain Worker's Compensation Insurance, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My Worker's Compensation Insurance Carrier and Policy Number are: CARRIER Rwd POLICY NUMBER ��:I_ (THIS SECTION NEED NOT COM D I PERMIT IS FOR ONE HUNDRED DOLLARS ($100) OR LESS). I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so a; to become subject to the Worker's Compensation Laws of lifomia. And agree that if I should become subject to the Worker's Gompe tion provisi sof Section 3700 of the Labo shall f. rTUryLth cp pl with t eisions. DATE: .•-' r!''�" APPLICANT: WARNING: Failure to secure Worker's Collpensati c ge is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,000), in addition to the cost of the compensation, damages as provided for in section 3708 of the labor code, interest, and attorney's fees. CONSTRUCTION LENDING AGENCY I hereby affirm under penalty of perjury that there is a Construction Lending Agency for the performance of the work for which this permit is issued (Sec. 3097, Civ. C.). LENDER'S NAME: LENDER'S ADDRESS: I certify that I have read this application and state that the above information is correct. I agree to comply with all city and county ordinances and state laws relating to building construction, and hereby authorize representatives of this county to enter upon the above-men ti oned property for inspection pur oses. V PERMITTEE NKME (PRINT) SIGNATURE OF PE ITTEE - DATE 4117 `di Q.I APPLICATION DATE: P/C# j ISSUE DATE: / // PERMIT# : /I l6 9 61 f TYPE CONST. OCC GROUP: G l Scope of Work # DWEL. UNITS # STORIES # BEDROOMS DESCRIPTION SQ. FT. FACTOR PSF ADJ. AREA/VALUATION SFR/ADD/REM Garage/Carport W Patio/Deck w LL Pool/Spa ZRe -Roof i Commercial m Valuation: 00 OVV Adj. Area: QUANTITY I DESCRIPTION FEE J Q U Q w J W co z M J (L > ♦"IT r r Z_U Q U w CONSTRUCTION: D PLAN REVIEW: ELECTRIC: PLUMBING: MECHANICAL: INSPECTION FEE: ISSUANCE: y,l SMTP: 17 ENERGY P/C: irI .1yTV ENERGY PERMIT: RETENTION FEE: I �Or lyO PRE -ALT FEE: BASF: PLOT PLAN: ZONING CLEARANCE: TOTALFEES j�J7rDy r �}�� 94 COMMENTS: P/C: A P, IQ PAID BY: VALIDATION: RECEIPT#®7 PAID BY: VALIDATION: WHITE — Department Copy, YELLOW — Finance Copy, PINK — Assessor Copy CITY OF DIAD • 6AR •+ trISPECTION RECORD ' INSPECTIONDATE INSPECTOR SETBACK/LETTER FOOTINGS FORMS SLAB UG. PLUMBING UG. ELECTRICAL LIFER GROUND SEWER LATERAL MAIN WATER LINE SEWER CLEANOUT ROOF SHEATHING FLOOR SHEATHING SHEAR WALLS EXTERIOR SHEAR WALLS INTERIOR FRAMINGNENTING ROUGH MECHANICAL r% ROUGH ELECTRICAL W( ) C ( ) ROUGH PLUMBING INSULATION WALL INSULATION CEILING DRYWALL Z LATH (PRE) LATH EXTERIOR LATH INTERIOR GAS TEST SCRATCH COAT ELECTRIC METER RELEASE GAS METER RELEASE SPECIAL INSPECTION FINAL BUILDING FINAL MECHANICAL FINAL ELECTRICAL FINAL PLUMBING T.C. of OCCUPANCY CERT. of OCCUPANCY COMMENTS: • DA •. TRACT AND LEDGER SWITCH GEAR COMMERCIAL HOOD T -BAR INTERCEPTER 1p HOT MOP/SHOWERPAN SEPTIC/CESSPOOL HERS REPORT RECEIVED DEMOLITION ROOF DRAINS ROUGH CONDUIT POOUSPA ROUGH PLUMBING ROUGH ELECTRICAL ROUGH MECHANICAL GAS TEST PRE GUNITE POOL PRE DECK BONDING P -TRAP FENCE / GATE/ ALARM FINAL POOL WALLS: WALL FOOTING/STEEL WALL STEEL 1-( ) 2ND( ) LIFT WALL BOND BEAM WALL DRAIN/ SEAL WALL FINAL R0. FRAMING PLANNING APPROVAL ROUGH FIRE APPROVAL FINAL FIRE DEPARTMENT FINAL PLANNING FINAL ENGINEERING/ PW FINAL COMMUNITY SERVICES FINAL HEALTH DEPT. FINAL INDUSTRIAL WASTE Test and Balance Report FOR Waba Grill @ Diamond Bar 1194 Grand Avenue Diamond Bar, CA 91765 General Contractor B&M Construction, Inc. 438 Fallingstar Irvine, CA 92614 T 949-677-1173 C 714-308-8574 bert33150sbcQ lobal. net The testing/adjusting/balancing of the air conditioning and commercial kitchen ventilation systems has been conducted in accordance with manufacturer's instructions and the National Environmental Balancing Bureau (NEBB) Procedural Standards for Testing, Adjusting and Balancing of Environmental Systems. Certified by Young S. Shin, PE f NEBB Certified TAB Professional YOUNG S. IN GBS COMPANY CER�� TE 900 S. Westmoreland Avenue, Suite 311 Los Angeles, CA 90006 ah'Ydronla5-4 Tel (213) 389-3982 Fax (213) 389-5146 September 14, 2016 T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 1/12 G Gia# company On A PROJECT INFORMATION PROJECT: Waba Grill Q Diamond Bar LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 B Air Conditioning System 1 (E ) RTU -1 : Rooftop gas heat/DX cool air conditioning unit of 7.5 -RT capacity with outside air intake hood is used to air condition the front areas as shown on the floor plan. Rooftop unit fan runs continuously during occupied mode. Programmbale digital room thermostat (Honeywell) controls the unit according to its time schedule. 2 (E ) RTU -2 : Rooftop gas heat/DX cool air conditioning unit of 7.5 -RT capacity with outside air intake hood is used to air condition the middle areas as shown on the floor plan. Rooftop unit fan runs continuously during occupied mode. Programmbale digital room thermostat (Honeywell) controls the unit according to Its time schedule. 3 EF -2: Ceiling mount exhaust fan is used for an unisex restroom exhaust. C Kitchen Ventilation System 1 KH -1: Llisted type 1 canopy hood is used to capture and exhaust grease laden air, heat, vapor and odors generated from cooking appliances under the hood. 2 EF -1: A roof mount centrifugal exhaust fan removes grease laiden air from KH -1. The system is operated by a wall mount toggle switch. The fan is electrically interlocked with MUA4. 3 MUA-1: The roof mount evaporative cooler with side discharge provides makeup air for KH -1. D TAB Work 1 Testing/adjusting/balacing work for the systems was performed on September 9, 2016. 2 Airflow rates for the systems were balanced within acceptable ranges. E Airflow Summary ®�y01J EN! �-NILSMM!11111! [(MIMI JIIIIIIMIlIliti> INUMM! 01111111LLQNNNLXIJ•1111111�1111111M! 1 11 ° 1' [l�I:i 11yJ �tt�hl�>• lit�1[�x}�>• • � � �� � � • � � �� NNAA' t�lNL•�itl•-- � � ��•]7���- � � � • .kli�� T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 2112 GBS J compang --offt PROJECT: Waba Grill (dl Diamond Bar LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 AIR OUTLET / INLET TEST REPORT DATE September 9, 2016 BY DH/YS Remarks: T16080 WabaG611 @ Diamond Bar 1194 Grand Ave 3112 Device Data Type A Round fully adjustable 4 cone calling diffuser I B Titus model PMG with border pe -3 for flush mount, RA Return Grille, Perforated Face OA Outside Air Intake Hood with aluminum filters at the unit E Exhaust grille integral with ceiling fan OM Outside Air Intake Hood at the unit Test Data Item No. System I Unit Service Name Type Duct Size In. Design Air Flow, cfm Actual % Des 1S1 RTU -1 See Plan A 12 600 601 100 1 S2 RTU -1 See Pian A 12 600 603 101 1S3 RTU -1 See Plan A 12 600 601 100 194 RTU -1 See Plan A 12 600 609 102 ISS RTU -1 See Plan A 12 600 601 100 Total SA 1 3000 3015 101 1 R1 RTU -1 See Plan RA 30' x 24' 2,600 2620 101 Total RA 2600 2620 101 1 OA RTU -1 See Plan OA 36 x 14 400 430 108 Total OA 2S1 RTU -2 See Plan A 14 860 885 104 2S2 RTU -2 See Plan A 14 850 878 103 2S3 RTU -2 See Plan B 6 100 105 105 2S4 RTU -2 See Plan B 12 400 381 95 2S5 RTU -2 See Plan B 12 400 391 98 2S6 RTU -2 See Plan B 12 400 399 100 Total SA 3000 3039 101 2R1 RTU -2 See Plan RA 16 850 860 101 2R2 RTU -2 See Plan RA 16 850 855 101 2R3 RTU -2 See Pian RA 16 900 889 99 Total RA 2600 2604 100 20A RTU -2 See Plan OA1 36 x 12 400 425 106 Total OA 2E1 EF -2 Resuoorn E 6 100 109 109 Remarks: T16080 WabaG611 @ Diamond Bar 1194 Grand Ave 3112 -GBS GBS company AIR OUTLET 1 INLET TEST REPORT PROJECT: Waba Grill ® Diamond Bar I DATE September 9, 2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY DH/YS Remarks: T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 4/12 Device Data Type SP 1S.pply Plenum erforated Test Data Item No. / System Unit Service Name Type Duct Size in. Design Air Flow, cfm Actual % Des MA1 MUA-1 Makeup Air for KH -1 SP 24 x 20 528 549 104 MA2 MUA-1 KN4 SP 24 x 20 528 552 105 MA3 MUMt KH -1 SP 24 x 20 529 573 108 MA4 MUA-1 KH -1 SP 24 x 20 529 579 109 MA5 MUA-1 KH -1 SP 24 x 20 529 571 108 MA6 MUA-1 KH -1 SP 24 x 20 529 568 107 MA7 MUA-1 KH -1 SP 24 x 20 528 558 106 Total 3700 3950 107 Remarks: T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 4/12 M Company GIN PACKAGED RTU UNIT UNIT TEST REPORT PROJECT: Waba Grill Q Diamond Bar DATE September 9, 2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY DH/YS Remarks: RTU -1 and RTU -2, each oDntroiled by its dedicated programmable room thermostat (Honeywell). T16080 WabaGrill ® Diamond Bar 1194 Grand Ave 5112 Unit Data Unit Number E RTU -1 E RTU -2 Location Roof Roof Service See Plan. See Plan. Type Packaged Gas Heat/DX Cool AIr Conditioning Unit Packs ed Gas Heat/DX Cool Air Conditioning Unit Manufacturer Trane Trane Model Number YSC092F3RLA YCD090C3LOBE Serial Number 123610728L P09102403D Cooling Capacity, Total / Sens.MB NL NL Heating .Input/output, MBH 120/88 120/96 Refrigerant Type R410A R-22 Compressor Type Scroll Scroll Condenser Fan (Quantity) Type Propeller Propeller c Type FC Centrifugal FC Centrifugal LL Rotation / Discharge CW/DownBlast CW/DownBlast Make/ Model Marathon/ 5K49RN4741 X A.O. Smith/ PQQA89a05 Frame 66 58z 0 Enclosure/ Type NL Service Factor 1.5 1.5 Type Beit Beit Belt Quantity / Size AX35 AX44 Motor Sheave OD/Bore, in. AK59 x 1 3112 x 5/8 Fan Sheave OD/Bore, in. IVL34 x 5/8 5 x 7/8 Centerline Distance, In. 113/4 163/4 Ak Filter Type / Quantity ! Size Throwaway (4) 20 x 26 x 2; MERV 8 Throwaway (3)16 x 25 x 2 Outside Air intake 36 x 14 36 x 12 Economizer Type Not Installed Not Installed , Test Data ., Item Design Actual Design Actual Air Flow, cfm 3,000 3,015 3,000 3,039 Outside Air Flow, c6n 400 430 400 425 Fan Speed, rpm NS 1050 NS 975 ESP, In. wg NS NV NS NV Voltage 208 211/210/209 208 209/2111209 Phase/Hz 3/60 3/60 3/60 3/60 Current.amperes 3.6 FLA 2.1/1.9/2.0 3.9 FLA 2.312.1/2.2 of Power, HP 1.0 1.0 1.0 1.0 Speed, rpm 1725 1710 1725 1697 Voltage 208 211/210/209 208 209/211/209 E Phsse/Hz 3/60 3/60 3/60 3160 (3 Current, amperes #1 14.5 RLA 8.5/7.9/8.1 27 RLA 18.2/15.1/15.9 Current, amperes #2 13.6 RLA 7.8f7.5/6.9 LL Voltage 208 211 208 209 O Phase/Hz 1/60 1/60 1/60 1/60 Current, amperes 4.0 FLA (0.75 HP) 2.4 3.4 FLA (0.5 HP) 2.1 Volta a 208 211/210/209 208 209/211/209 Phase / Hz 3180 3160 3/60 3/60 Current 39.3 MCA 20.8/19.7/19.4 41.1 MCA 20.6/19.3/20.2 Remarks: RTU -1 and RTU -2, each oDntroiled by its dedicated programmable room thermostat (Honeywell). T16080 WabaGrill ® Diamond Bar 1194 Grand Ave 5112 PROJECT: Waba Grill 9b Diamond Bar LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 FAN TEST REPORT DATE September 9, 2016 BY DHNS Remarks: fan controlled by light switch T16080 WabaGrill ® Diamond Bar 1194 Grand Ave 6/12 Unit Data Unit Number EF -2 Location Calling Mount Service Restroom Exhaust Type Ceiing Mount Exhaust Fan Manufacturer NV Model Number NV Serial Number/ Job Number NV Fan Type FCCentrifugal Motor Type NV Drive Direct „Test Data Item Design Actual Alrtlow, cfm 100 109 a Speed, rpm NS NV SP, in. wg NS NA Power, HP NS NA Speed, rpm NS NA Voltage, 115 NV Phase/Hz 1/60 NV Current, amperes NS NV Remarks: fan controlled by light switch T16080 WabaGrill ® Diamond Bar 1194 Grand Ave 6/12 G� Gas company KITCHEN HOOD PROJECT: Waba Grill @ Diamond Bar DATE September 9, 2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY OHMS Remarks: T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 7/12 TYPE 1 KITCHEN,HOOD TEST REPORT TYPE 1, KH ; Hood Data Grease Filter Data Hood No KH -1 Size: L x. W x H 14' 11" x 54"x 24" Type Bathe Location Kitchen Available Length, In. 179 Construction Stainless Steel Job No. 2615265 Exposed Sides 2 Size, in. (HxW) (11) 20 x 16 x 2 -Type Listed Type 1 Airflow: CFM 4400 Free Area, (ftz) 1.78 Make/Model Ca fiveAire/5424ND-2-PSP-F Serving Fan KEF-1 Make/Modal Ca trate Solo Filter Other Data Grease Dud Size, in. 14 x 28 Grease Duct Area, fe 2.72 Hood Lower Lip to Floor,in. 80 Distance Between Lower Lip of Hood and Cooking Surfaces, in. 48 Appliances Under Hood: 2 Rice cookers, 2-Bumer hot plate, Griddle Charbroiler, Steam table, Griddle Teat Data Item Design Actual % Design Airflow, O, CFM 4,400 4,628 105% Veloctly Readings Across Grease Filters, V, fpm Filter Number POINTS #1 #2 #3 #4 #5 Total 1 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 188 179 190 228 219 230 235 226 237 255 246 257 278 269 280 2 183 189 181 223 229 221 230 236 228 250 256 248 273 279 271 3 191 195 197 231 235 237 238 242 1 244 258 262 264 281 285 287 Vav = V sum -1 9 188 228 235 255 278 Free Area 1.78 1.78 1.78 1.76 1.78 Filter CFM 335 406 418 454 495 2109 Filter Number POINTS #6 #7 #8 #9 #10 Total 1 1 2 1 3 1 2 3 1 2 3 1 2 3 1 2 3 1 296 287 298 281 272 283 250 241 252 224 215 226 192 163 194 2 291 297 289 276 282 274 245 251 243 219 225 217 187 193 185 3 299 303 305 284 288 290 263 257 259 227 231 233 195 199 201 Vav = V sum / 9 296 281 250 224 192 Free Area 1.78 1.78 1.78 1.78 1.78 Finer CFM 527 500 445 399 1 342 2214 Filter Number POINTS #11 Total 1 2 3 1 172 163 174 2 167 173 165 3 175 179 181 Vav = V sum / 9 172 Free Area 1.78 Filter CFM 306 306 Remarks: T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 7/12 4,im G R$ c o m P a Id y EXHAUST FAN @Qt PROJECT: Waba Grill @ Diamond Bar LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 DATE September 9, 2016 BY DH/YS EXHAUST FAN TEST REPORT EF BD .. Unit Data` Unit No. KEF-1 (EF -1) Location Roof Service KH -1 Type Upblst Ven0lator Manufacturer Cook Model 195VCR B Serial Nod Job Number 138SG36633-0D/0017508 `a Type BI Cerdrifugal U! Rotation / Discharge CCW/Upblast Make Baldor Model / Cat. No. EHM3157T / 35VV807M496G1 Frame 145T ,Enclosure/Type NL Service Factor 1A5 Type Bah o Belt a Size AX23 c Motor Sheave OD/Bore, in. MVL40 x 7/8 31/4 Fan Sheave OD/Bore, in. AK49 x 5/8 (4 3/4) Centerline Distance In. 6 Test Data Item Design Actual Design Actual Airflow, cfrn 4,400 4,628 m wed, rpm NS 1197 LE SP, in. wg 1.5 NV Power, HP 2.0 2.0 Speed, rpm 1750 1721 8 � Voltage, 208 211/209/210 Phase / Hz 3/60 3/60 Currentamperes 5.8 FLA 4.06/3.80/3.91 Remarks: T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 8/12 GBS Gtrs company PROJECT: Wabe Grill !rd Diamond Bar LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 EVAPORATIVE COOLER TEST REPORT DATE September 9, 2016 BY DH/YS Remarks: Unit shall be electrically interlocked with KEF-1. T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 9/12 UNITIDATA Unit No. MUA-1 Location Roof Service KH -1 Type Direct Contact Manufacturer Fri ikin Model FS650A Serial No. 2574445 Twe FC Centrifugal c ti Rotation CW Discharge Top Horizontal Make Dial Model/ Item No. /2205 Type S 0 Enclosure ODP Frame 56Z Service Factor 1.0 Type Bek Belt Quantity / Size 4L 690 Motor Sheave OD/Bore, in. MVL40 x 1/2 (3 114) Fan Sheave OD/Bore, in. 14 x 1 Sheave Centedirte Distance, in. 20 TEST DATA Items Design Actual Design Actual Airflow, of n 3700 3950 L Speed, m NS 1194 ESP, in. wg 0.6 NV Power, HP 0.75 0.75 Seed, rpm 1.725 1740 voltage 115 118 Phase / Hz 1/60 1/60 Current amperes 10,8 FLA 6.4 Remarks: Unit shall be electrically interlocked with KEF-1. T16080 WabaGrill @ Diamond Bar 1194 Grand Ave 9/12 Gas company PROJECT: Waba Grill @ Diamond Bar DATE 9/9/2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY DH/YS Instrument No. LEGEND AND ABBREVIATIONS ..- .. ._ , :. LA CFD Calculated from Field Obtained Data NA Not Applicable/ Not Available CFM Cubic Feet Per Minute No, Number DB Dry Bulb Temperaturr NPD Nameplate Data IF Degrees Fahrenheit NS Not Specified or indicated In. dia Inches in diameter NT Not Tested Due To Unfavorable Conditions IN. WG Inches Water Gage NV Not vedfled KH Type 1 Hood KEF Exhaust Fan for Type 1 hood RTU Packaged Gas Heat/ DX Cool Air Conditioning Unit OAI Outside Air Intake EF Exhaust Fan EC Evaporative Cooler KEF Exhaust Fan for Commercial kitchen Hood WB Wet Bulb Temperature MUA Evaporative Coder as Makeup Air Unit CW Clockwise DWDI Double Width Double Inlet CCW Counterclockwise TH Top Horizontal (E) Existing FLA Full Load Amperes SF Service Factor MCA Maximum Current Load HP Horsepower MOCP Maximum Overcurrent Protection Hz Hertz, Cycles per Second BI Backward Inclined ODP Open Drip -Proof UTR Up through roof OD Outer Diameter rpm lRevolutlons Per Minute UB jUpBlast Instrument No. .TAB TEST ,INSTRUIiIENT LIST . VMA AN Function Instrument No. AN TKM FH Function Air Velocity Measuring Rotating Measuring Air Volume Measuring (Direct) Range 50 to 4,500 fpm 6 to 30,000 rpm 0 to 2,500 cfm Min. Accuracy t2% tl rpm t3% Namefrype Rotating Vane Anemometer Optical and Contact Capture Hood w/ Digital Display Manufacturer Extech SNMPO Shortridge Model 707412 DT205B ADM850 Serial No. L539314 49801083 M95864 Calibration Date 1/13/2016 1 1/13/2016 1/1312016 Instrument No. VMA VMA AN Function Voltage, AC Current, Amps Air Velocity Measuring Range 0 to 750 VAC 0 to 80D amps 50 to 4,500 fpm Min. Accu t 1% % of full scale 3 % of full scale t2% Name/r Voltmeter Amp Probe Hot-wire Multifunction Anemometer Manufacturer Extech Extech Kanomax Model 382040 382040 6501 Series Serial No. 96MA165011 96MA165011 6531260212 Calibration Date 1/13/2016 1/13/2016 1/13/2016 Remarks: T16080 WabaGriA @ Diamond Bar 1194 Grand Ave 10/12 GB FLOOR PLAN G 0 9 aafiftPan9 PROJECT: Waba Grill ® Diamond Bar DATE September 9, 2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY DHNS T16080 WebaGrili @ Diamond Bar 1194 Grand Ave 11112 GBj:ROOF PLAN G 0 S 0 0 M p® A 9 PROJECT: Waba Grill ® Diamond Bar DATE September 9, 2016 LOCATION: 1194 Grand Avenue, Diamond Bar, CA 91765 BY DHNS —EXISTING ROOF ACCESS UDDER. VERIFY IN. FIELD. REFER PLUMBING PLANS FOR,CODE.REQUIRED A I EF CONDENSATE. OPAIN PIPING. y 1 e t 1 1 � r i F- 71 RADNS GE=L AIR -- IR / ( I REBALAIHCE 10 MIN 400 CFM. F. J XWAU"T DISCHARGE MIN. 10 -0' RAMS FROM! \ Rlitt nlWr: oprut"t, PRnPEDM1'v INC. ABOVE. GRADE. MTD FRESH ADT INTME. / EXISTING 7.5 TON PACKAGE— ROOFTOP ACKAGE --ROOFTOP UIM RTU -1. i REBALANCE TO 3.000 CFM. EXISTING OUTSIDE AIR IIJTAKE. REON?/X.E. TO I MIN 400 CFM, I/ I i I t Ili LEMATING ROOF F. /` XIS TxtG 7.5 TION PACKWE--1 ROOFTOP UNIT RTU -2 REBALANCE TO 3,000 CFM. N MECHANICAL ROOF PLAN —� _SCALE: 1%d., -j' -p" Ti6080 WabaGrill @ Diamond Bar 1194 Grand Ave 12/12