HomeMy WebLinkAboutTR_47851_Lot 26flatTincton CO Chtkal flgifleefifi& Ific. December 6, 1994 Mr. Bernist Mazur DIAMOND EAST PARTNERS 2050 Valderas Road Glendale, CA 91208 SUBJECT: Geotechnical Review of Precise Grading Plan, Foundation Plan and Foundation Details for Lot 26, Tract 47851, Crystal Ridge Estates, Diamond Bar, California HGE1 Project No. 91-02-0109A-26 REFERENCES: Dear Mr. Mazur: 1) Precise Grading Plan for the Subject Lot, Undated, Prepared by Lanco Engineering. 2) Foundation Plan, Sheet 7, Dated November 4, 1994, and Details, Sheet D-1, Dated September 4, 1994, for the Subject Lot, Prepared by R. Gould and Associates, Inc. 3) "Geotechnical Report of Rough Grading for Lots 1-17 and 20-48, Vesting Tentative Tract 47851, Diamond Bar, California," Dated October 11, 1994, by HGEI, Project No. 91-02-0109A. In response to a request from Mr. Richard Gould and your authorization we have reviewed the referenced precise grading plan, foundation plan and foundation details for Lot 26 of Tract 47851. The referenced plans and details were reviewed from a geotechnical standpoint for conformance with our recommendations only. These plans and details were not reviewed as to the accuracy of dimensions, measurements, calculations or any non-geotechnical portion of the design. Based upon our review it appears that the referenced plans and details are in general conformance with our previous recommendations. During this review the following items were noted: Batavia Business Center, 1938 North Batavia Street, Suite N, Orange, CA 92665 (714) 637-3093 ® (800) 924-7645 • FAX (714) 637-3096 DIAMOND EAST PARTNERS Project No. 91-02-0109A-26 December 6, 1994 Page 2 No significant changes to the building pad elevation and/or adjacent descending slopes are currently planned. The homeowner should be informed that future grading to alter the pad and/or slopes should not be performed without review by a geotechnical consultant familiar with rough grading of the tract. In addition, the homeowner should be informed of the importance of slope landscaping, maintenance and erosion control and should be provided with the guidelines that were appended to the referenced rough grading, report (Appendix C). 2. The northerly side of the proposed structure is located at approximately the toe of the existing ascending side yard slope. In order to provide a five -foot -wide access to the rear yard the toe of the slope will need to be removed and replaced with a five -foot -high retaining wall. The overall height of the slope is approximately 18 feet. In our opinion, from a geotechnical standpoint, the H/2 setback as required by the Uniform Building Code is not necessary. However, the minimum setback between the house and the retaining walls should be five feet as shown on the precise grading plan. 3. The proposed structure is located at approximately the top of descending slopes in the front and along the southerly side of the lot. Adjacent to the top of these slopes the house footing should be deepened as necessary to provide a minimum distance of five feet between the outside edge of the footing and the slope face. 4. Preliminary laboratory testing indicates that the on -site surface soils have a medium expansion potential and moderate concentrations of water-soluble sulfate as defined by the Uniform Building Code. As a result the floor slab design should be revised to agree with Foundation/Slab Type III as presented on Table A of the referenced rough grading report (Ref. 3). Also, provision of Table 19-A-3 of the Uniform Building Code (1994 Edition) apply to all concrete in contact with the soil. The expansion potential and sulfate concentrations should be confirmed by additional sampling and testing at the time of precise grading. As requested by Mr. Gould, we have stamped and signed three copies of the precise grading plan and have returned them to him along with copies of this letter. DIAMOND EAST PARTNERS Project No. 91-02-0109A-26 December 6, 1994 Page 3 We trust that this letter/report is adequate for your current needs. If you have any questions or require additional assistance, please call. Very truly yours, HARRINGTON GEOTECHNICAL ENGINEERING, INC. Prepared By: Reviewed By: Don P. Harrington, Sr., P.E. President Distribution: Addressee - 2 R. Gould & Associates - 3 (with copies of Precise Grading Plan) Q\D0CS\DBAR\0109A26. RV W