Loading...
HomeMy WebLinkAbout20200909113038027 (11)October 9, 1995 '5-5A xu w f f vie " C ,.. a Mr. Bernist Mazur DIAMOND BAR EAST PARTNERS 3480 Torrance Boulevard, Suite 300 Torrance, CA 90503 SUBJECT: Response to the City of Diamond. Bar Memorandum for 2838 Bentley Way, Lot 8, Tract 47851, Diamond Bar, CA HGEI Project No. 91-02-0109A-08 REFERENCES: 1) City of Diamond Bar Memorandum from Mike Myers to Anne Garvey for the Subject Lot, Dated September 29, 1995 2) Geotechnical Review of Precise Grading Plan, Foundation Plan & Details for the Subject Lot, Dated December 6, 1994, by HGEI, Project No. 91-02-0109A-08. 3) Grading Plan for the Subject Lot, Revised August 7, 1995, by Lanco Engineering. 4) "Geotechnical Report of Rough Grading, Lots 1 Through 17 and 20 Through 48, Vesting Tentative Tract 47851, Diamond Bar, CA," Dated October 11, 1994, by HGEI, Project No. 91-02-0109A. Dear Mr. Mazur: In response to a request from Richard Gould with JCC Homes, Harrington Geotechnical Engineering, Inc. is presenting this response to the referenced City of Diamond Bar Memorandum. The memorandum, a copy of which is attached, contains a comment related to the location of the house in respect to the restricted use area shown on the plan. It is our understanding that the restricted use area shown on the 20-scale grading plan (Ref. 3) is the same as the special foundation zone established during the pre -rough grading design of the shear key and is based upon a 1:1 projection from the anticipated toe of the shear key. The actual location of this projection, based upon the as -built location of the shear key, is denoted foundation setback" on Plate A-2 of the referenced rough grading report. Since this Batavia Business Center, 1938 North Batavia Street, Suite N, Orange, CA 92665 (714) 637-3093 - (800) 924-7645 - FAX (714) 637-3096 DIAMOND BAR EAST PARTNERS Project No. 91-02-0109A-08 October 9, 1995 Page Two foundation setback line is based upon as -built information, it is our opinion that it supersedes the restricted use zone boundary shown on the referenced grading plan. The location of the actual foundation setback line is between zero and ten feet in from the top of the descending rear slope. As stated in our December 6, 1994, letter/report (Ref. 2), the structure is located at least 20 + feet back from the top of this slope and is therefore outside the limits of the final as -built footing setback area. Thus, the location of the structure as shown on the grading plan is in conformance with the approved geotechnical report. We trust this response is acceptable to the City. If you have any questions or require further assistance, please call. Very truly yours, Distribution: Addressee (2) City of Diamond Bar (3 - via Overnight Mail) attn: Anne Garvey Attachment Q\D0CS\DBAR\0108-8. RSP