Loading...
HomeMy WebLinkAboutTraffic Signal Interconnect17 8 11 a O �1Y I Z o_ ly0�, Of_` LJ CL a / z N W Q O _ U w m � m W W h 0 0 1a DRAWN Z SPOTTED AS BUILT SUPERVISED BY w J EXISTING 2" CONDUIT WITH 1-12 PAIR #19 INTERCONNECT CABLE. so _ 81 -7- 4 Im O z a 2 3 1 O + TYPICAL. N Q F— c� G O L D E N B a a a a 0 2 0 Ian L O1 V) N N S P R I N G S D R I V E N GENERAL NOTES 1. ALL MATERIAL AND WORK SHALL CONFORM TO MAY 2006 STANDARD PLANS AND SPECIFICATIONS OF THE CALIFORNIA DEPARTMENT OF TRANSPORTATION. 2. ALL CONDUIT SHALL BE 2—INCH SCHEDULE 80 PVC CONDUIT USING 45—DEGREE SWEEP ELLS INTO INTERCONNECT PULL BOXES. EACH CONDUIT RUN SHALL INCLUDE A NYLON PULL TAPE. 3. ALL PULL BOXES SHALL BE NO. 6 OR NO.6E AS NOTED. MAXIMUM PULL BOX SPACING IS 1,300 FEET FOR FIBER—OPTIC CABLE. AND 325 FEET MAXIMUM SPACING FOR COPPER CABLE, UNLESS OTHERWISE SHOWN. CONSTRUCTION NOTES INSTALL 2" INTERCONNECT CONDUIT AS SHOWN, UNLESS OTHERWISE NOTED. OINSTALL NO. 6 PULL BOX, UNLESS OTHERWISE NOTED. REPLACE EXISTING PULL BOX WITH NO. 6 OR NO. 6E PULL BOX AS SHOWN. 4 INSTALL 12 SMFO CABLE BETWEEN SPLICE CLOSURE AND CONTROLLER CABINET OR MODEL 334—TV CABINET. INSTALL 24 SMFO CABLE. INSTALL 1-12 PAIR #19 INTERCONNECT CABLE. INSTALL 1 DLC CABLE CONTINUOUS BETWEEN CONTROLLER AND LOOPS. B INTERCEPT, REWORK AND EXTEND EXISTING INTERCONNECT CONDUIT(S) AS SHOWN. REMOVE EXISTING PULL BOX AND JOIN CONDUITS AS SHOWN. 10 REMOVE EXISTING PULL BOX AND EXISTING 90—DEGREE CONDUIT ELL(S). REWORK CONDUIT(S) AND INSTALL 45—DEGREE SWEEP ELL(S) AND SET NO. 6 PULL BOX AS SHOWN. REINSTALL DETECTOR CABLE(S) WHERE REQUIRED. SEE DETAILS PER SHEET 16. U INSTALL NO.6E PULL BOX INCLUDING 2—INCH CONDUIT TO ADJACENT PULL BOX AS SHOWN. REINSTALL DETECTOR CABLE(S) WHERE REQUIRED. 12 INSTALL FIBER OPTIC SPLICE ENCLOSURE AS DETAILED ON SHEET 16. 13 INSTALL CABINET MOUNT INTERFACE CENTER AND RACK MOUNT POWER DISTRIBUTION UNIT. TERMINATE 12 SMFO AS REQUIRED. 14 INSTALL NO. 6 PULL BOX FOR FUTURE LOOP DETECTORS, INCLUDING 1.5— INCH DETECTOR STUB —OUT, UNLESS OTHERWISE NOTED. 15 ENTER EXISTING PULL BOX WITH NEW CONDUIT(S) AS SHOWN. 16 INSTALL NEW TYPE M160-50 INTERCONNECT TERMINATION ASSEMBLY COMPLETE INCLUDING RS232 CABLE ASSEMBLY AS REQUIRED PER CABLE TERMINATION DETAIL ON SHEET 17. 17 TERMINATE INTERCONNECT CABLE(S) AS REQUIRED. SEE DETAILS SHEET 17. 18 ENTER EXISTING PULL BOX WITH CONDUIT AS SHOWN. REQUIRED DLC IS COILED IN PULL BOX. INSTALL DLC IN NEW CONDUIT AND SPLICE TO EXISTING (OR NEW) LOOPS. BASED ON INFORMATION PROVIDED BY CONTRACTOR AND CITY INSPECTOR WARREN C. SIECKE, R.C.E.18707 DATE 0 (3 )Cl- X6 11 "ITS Q�OF ESS%�Ne' BEN s/F Fy No. 18707 m * CI Vll x 0f C P R E P A R E D B v ��f a"" el s, e TRANSPORTATION & TRAFFIC ENGINEERING 20142 CANYON DRIVE YORBA LINDA, CALIFORNIA 92886 ( 714 ) 970-6247 / q �%G !e`er SUBMITTED DATE RECOMMENDED DATE APPROVED DATE WARREN C. SIECKE R.C.E. NO. 18707 MATCH LINE SEE PtTTT----- HEET II UPPER RIGHT STA, 11+60.05 A s,Imilm GROUP N-2 - - CITY OF DIAMOND BAR TRAFFIC SIGNAL INTERCONNECT LINKS - PHASE 2 GOLDEN SPRINGS DIRVE HIGH KNOB ROAD - TEMPLE AVENUE BY C.C. SH.7 20F 171 SCALE 1" = 40' AS BUILT