GENERAL NOTES
1. ALL MATERIAL AND WORK SHALL CONFORM TO MAY 2006 STANDARD PLANS AND
SPECIFICATIONS OF THE CALIFORNIA DEPARTMENT OF TRANSPORTATION.
2. ALL CONDUIT SHALL BE 2—INCH SCHEDULE 80 PVC CONDUIT USING 45—DEGREE
SWEEP ELLS INTO INTERCONNECT PULL BOXES. EACH CONDUIT RUN SHALL
INCLUDE A NYLON PULL TAPE.
3. ALL PULL BOXES SHALL BE NO. 6 OR NO.6E AS NOTED. MAXIMUM PULL BOX
SPACING IS 1,300 FEET FOR FIBER—OPTIC CABLE. AND 325 FEET MAXIMUM
SPACING FOR COPPER CABLE, UNLESS OTHERWISE SHOWN.
CONSTRUCTION NOTES
INSTALL 2" INTERCONNECT CONDUIT AS SHOWN, UNLESS OTHERWISE NOTED.
OINSTALL NO. 6 PULL BOX, UNLESS OTHERWISE NOTED.
REPLACE EXISTING PULL BOX WITH NO. 6 OR NO. 6E PULL BOX AS SHOWN.
4 INSTALL 12 SMFO CABLE BETWEEN SPLICE CLOSURE AND CONTROLLER CABINET
OR MODEL 334—TV CABINET.
INSTALL 24 SMFO CABLE.
INSTALL 1-12 PAIR #19 INTERCONNECT CABLE.
INSTALL 1 DLC CABLE CONTINUOUS BETWEEN CONTROLLER AND LOOPS.
B INTERCEPT, REWORK AND EXTEND EXISTING INTERCONNECT CONDUIT(S) AS SHOWN.
REMOVE EXISTING PULL BOX AND JOIN CONDUITS AS SHOWN.
10 REMOVE EXISTING PULL BOX AND EXISTING 90—DEGREE CONDUIT ELL(S).
REWORK CONDUIT(S) AND INSTALL 45—DEGREE SWEEP ELL(S) AND SET NO.
6 PULL BOX AS SHOWN. REINSTALL DETECTOR CABLE(S) WHERE
REQUIRED. SEE DETAILS PER SHEET 16.
U INSTALL NO.6E PULL BOX INCLUDING 2—INCH CONDUIT TO ADJACENT
PULL BOX AS SHOWN. REINSTALL DETECTOR CABLE(S) WHERE REQUIRED.
12 INSTALL FIBER OPTIC SPLICE ENCLOSURE AS DETAILED ON SHEET 16.
13 INSTALL CABINET MOUNT INTERFACE CENTER AND RACK MOUNT POWER
DISTRIBUTION UNIT. TERMINATE 12 SMFO AS REQUIRED.
14 INSTALL NO. 6 PULL BOX FOR FUTURE LOOP DETECTORS, INCLUDING 1.5—
INCH DETECTOR STUB —OUT, UNLESS OTHERWISE NOTED.
15 ENTER EXISTING PULL BOX WITH NEW CONDUIT(S) AS SHOWN.
16 INSTALL NEW TYPE M160-50 INTERCONNECT TERMINATION ASSEMBLY COMPLETE
INCLUDING RS232 CABLE ASSEMBLY AS REQUIRED PER CABLE TERMINATION
DETAIL ON SHEET 17.
17 TERMINATE INTERCONNECT CABLE(S) AS REQUIRED. SEE DETAILS SHEET 17.
18 ENTER EXISTING PULL BOX WITH CONDUIT AS SHOWN. REQUIRED DLC
IS COILED IN PULL BOX. INSTALL DLC IN NEW CONDUIT AND SPLICE
TO EXISTING (OR NEW) LOOPS.
BASED ON INFORMATION PROVIDED BY
CONTRACTOR AND CITY INSPECTOR
WARREN C. SIECKE, R.C.E.18707 DATE
0
(3 )Cl- X6
11
"ITS
Q�OF ESS%�Ne'
BEN s/F Fy
No. 18707 m
*
CI Vll
x 0f C
P R E P A R E D B v
��f
a"" el s, e
TRANSPORTATION &
TRAFFIC ENGINEERING
20142 CANYON DRIVE
YORBA LINDA, CALIFORNIA 92886
( 714 ) 970-6247
/ q
�%G !e`er
SUBMITTED
DATE
RECOMMENDED
DATE
APPROVED
DATE
WARREN C. SIECKE R.C.E. NO. 18707
MATCH LINE SEE
PtTTT----- HEET II UPPER RIGHT
STA, 11+60.05
A
s,Imilm
GROUP N-2 -
- CITY OF DIAMOND BAR
TRAFFIC SIGNAL INTERCONNECT LINKS - PHASE 2
GOLDEN SPRINGS DIRVE
HIGH KNOB ROAD - TEMPLE AVENUE
BY C.C. SH.7 20F 171 SCALE 1" = 40' AS BUILT