Loading...
HomeMy WebLinkAboutPlansCITY OF DIAMOND BAR Z C PROJECT SITE VICINITY MAP NTS AGENCIES TO BE NOTIFIED SERVICES CONTACT TELEPHONE NO. CALTRANS - DISTRICT 7 -- (213) 897-3631 LORBEER MIDDLE SCHOOL -- (909) 397-4563 L.A. CO. DEPT. OF PW - (626) 458-1708 OPERATION SERVICES L.A. CO. DEPT. OF PW - (626) 458-7117 SEWER MAINTENANCE L.A. CO. FIRE DEPT. - (909) 598-4290 STATION 119 L.A. CO. FIRE DEPT. - (909) 861-5995 STATION 120 L.A. CO. FIRE DEPT. - (909) 396-0164 STATION 121 L.A. CO. SHERIFF'S DEPT. -- (909) 595-2264 POMONA UNIFIED SCHOOL DISTRICT -- (909) 397-4800x3069 WASTE MANAGEMENT -- (800) 266-7551 CLEAR CHANNEL OUTDOOR KEVIN KOCIC (213) 305-0045 LA CO. DEPT. OF PW - MARSSA MORELOS (626) 300-3365 ROADWAY CROWN CASTLE DAVID ANTOL (724)416-2180 SC GAS BREA - TRANSMISSION ROSALYN SQUIRES (818)701-4546 SC GAS - INDUSTRY PETER SERRANO (714)634-5067 SOUTHERN CALIFORNIA EDISON CINDY VERRENGIA (714) 895-0188 SOUTHERN CALIFORNIA EDISON - MIROSLAVA LICON (909) 592-3761 DISTRIBUTION SOUTHERN CALIFORNIA EDISON - RICHARD OROZCO (909) 394-2814 TRANSMISSION SOUTHERN CALIFORNIA EDISON - ERIC LOPEZ (626) 422-9256 TRANSMISSION VERIZON - POMONA ARIEL FATALLA (909)469-6333 WALNUT VALLEY WATER DISTRICT ED CASTANON (909) 595-1268 x267 METROPOLITAN WATER DISTRICT FRANCISCO FLORES (213)217-6679 REVISIONS CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY RCE NO. CHECKED BY DATE DEPARTMENT OF PUBLIC WORKS RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT PROJECT NO.01415 BENCHMARK: hL PREPARED BY: ONWARD ENGINEERING 300 S. HARBOR BLVD., SUITE 814 ANAHEIM, CA 92805 T: (714) 533-3050 F: (714) 808-1270 jj /7 'z 78314 3/24/2015 Justin L. Smeets, P.E. R.C.E. No. DATE QOoFESS l L co c� ) m � x * No.78314 s civic �qTF OF CA��F�/ SUBMITED REVIEWED APPROVED !` ; CITY ENGINEER R.C.E. DATE SHEET SCHEDULE SHEET NO. DESCRIPTION 1 TITLE SHEET 2 RESIDENTIAL AREA 3 3 RESIDENTIAL AREA 3 4 RESIDENTIAL AREA 3 5 RESIDENTIAL AREA 3 6 RESIDENTIAL AREA 3 7 RESIDENTIAL AREA 3 8 RESIDENTIAL AREA 3 9 RESIDENTIAL AREA 3 10 RESIDENTIAL AREA 3 11 RESIDENTIAL AREA 3 CITY OF DIAMOND BAR TITLE SHEET RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT DEPARTMENT OF PUBLIC WORKS PROJECT NO. DATE : 01415 1 3/24/2015 SHEET 1 OF 12 SHEETS ' \ I \ I I \o I 41 2 2 'X24' I I I I 40 x 40 ** 20'X20' 2 O I � 41 40 ***; 0 41 o*t ° 0 0 0 � t *t O + * t O O 3 +* O O O O O t xxttx*� O x t 3 x \ *+** 43 O \41 ' 40 ++t* I 0 0 u \ t O I O Z / 41 *+t * 40 O O O O O 0000 O 41 � I � O O O O m + 2 + O /o 0 0 O1 0 o 40 I * * + +* tt/ O O O O O O O O 40 3 / + 40 t * O O - A / +*+t * O O + 0 O 41 WOODVI CT 0 * * O O 40 ' tt +/ 0 0 / 0 \\�\ - - O *t 41 .* +t t t O -- I 2 4'X20' r, ttt+ 43 O O 0 O O O O 41 I \ Y*+t*+/ 6'X15' 2 0 O 0 O 0 — — 06'X17' 2 4'X55' 40 8 X ' 2 6'X21' 2 40 * t+ 2 6'X14' 2 40 0 O 40 RAVENWOD T **+•*t.+*+*t* ++�- --�*0+ * `+++*.**++ ++t t' *+****+*' *x 41 40 40 41 43 _ �+ ++ ++ 43 * x x x Q / *+/++* t 43 — * 8'X62' 2 t + * + ++ 2 6,X6, * ++� + + —41 ** 4'X82' 2 -- +++ +t** t* 6 CJ *t + tt *t+ 4'X4' 2 43 �� * x x * 43 + + t + + CID /' *t *f' + + ? l+ + t. tx * 4'X6' <C/t. o * 43 * t t x + �x + x x * t + * t * x * 4'X13' 2 �. t + t + +* +* + + 43 I — \ I \ / \ I I / \ REVISIONS CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE BENCHMARK: 00 O O 00 O O 00 O O 00 O 00 O^ I � I / I / / I / / I / 43 / i I , , I / � I I / I I 43 i 1 6'X 16' 2 40 43 L2 I I X31' \p X 13' 2 10' 1 2 11' 2 43 D 4'XlQ' 2 6'X11' 2 I I W� + Z x x ** ** t x t S t tom* * * Lu �w cn GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 10 PROTECT IN PLACE. REMOVALS 20 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3o SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4o REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8o REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB # RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: +++++++++++*+ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND O 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). L r t C L Q� IFESS/p L . , —� m c� No. 78314 * GRAPHIC SCALE = 100 (P 0 50 100 200 C/VIL OF CAL�1 " = 100' ( CITY OF DIAMOND BAR r ROADWAY MAINTENANCE PLANS PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3 300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT ANAHEIM, CA 92805 T: (714) F: (714) 533-3050 808-1270 REVIEWED ` PUBLIC WORKS DEPARTMENT 78314 3/24/2015 APPROVED y a1>.iFa CITY EN9NEEf f ) Iq -5 R.C.E. PROJECT N0. DATE JUSTIN L. SMEETS, P.E. R.C.E. No. DATE DATE 01415 3/24/2015 SHEET 2 OF 12 SHEETS r GENERAL CONSTRUCTION NOTES: %7 43 i x / * � 43 + x % \ O , 40- % 43 0 \ x 43 % x 40 Ns Al 40 / 40 x % 43 43 x / 43 \ \ %� * LL +\*+* **� - - R/DGE O 43 % + / NTDR 43 43 A n)40 43 43 % + 43 40 I 43 \ x 43 \ \ xx x 43 %x xx x - x 40 x x x 40 �xx 43 x x x % % 43 I ' ' %x I / % xx xx x�x '` x 43 �x x I x x% * 40 \',xxx % z x xxx xxx 43 43 x x x S DIAMOND CANYON R 43 x x % x % xxxx x x -� x /xxx % % x�' 43 43 x %\ x x x x x x _ xx -,._ % x x x x / x x x x/� REVISIONS CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE BENCHMARK: PREPARED BY: ONWARD ENGINEERING 300 S. HARBOR BLVD., SUITE 814 ANAHEIM, CA 92805 T: (714) 533-3050 F: (714) 808-1270 i� 78314 3/24/2015 JUSTIN L. SMEETS, P.E. R.C.E. No. DATE SUBMITED REVIEWED /1k F APPROVEd\-�i' , .4' CITY ENGINEFR R.C.E. DATE 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS 2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 0 REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB # RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN ,AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY \ CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND O 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE O SAW CUT & REMOVE FULL DEPTH (STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). Q�OFESS/co co 0� �+ m L � � * No. 78314 * GRAPHIC SCALE 100 0 50 100 200 `P C/VIA �qTF OF CA\_\F 1 " = 100, I CITY OF DIAMOND BAR I ROADWAY MAINTENANCE PLANS RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT PUBLIC WORKS DEPARTMENT PROJECT NO. DATE : 01415 1 3/24/2015 SHEET 4 OF 12 SHEETS 41 i� ------ 43 / — I + +' 9S �` * +� I , 40 / ,CO 2 6'X33' ++ + ��<r A_ \\\ 2/ �� 1 // I 41 40 OHAN CT 41 10 X22 \ 2 1+ 41 '9< 43 \ \ 40 `0� \� ' / \ 27' 2 T ' 40 43 i -- ' / \ 43 +++ ' — — I 6'X17' I++ 40 I _ + I 1 1 1 3 T U + + I JI I — — — / A I I I I I I Q W +' — -- / 3 41 40 41 A 40 3 A +I FALLOW,, 2 10'X152' I 3 + A 3 40 R 41 41 40 41 S Lu co I 40 41 _ — w 41 cf) I I I — I REVISIONS 57 FREEWAY I 1 I 1 1 1 I I I I 40 I I I I I I I I I I I I I I I I I I 43 43 I I I I / / 77//= ZY I I I I I I I I 1 1 43 I 1 40 1 40 43 IGGER LN 40 43 43 --——�---� —�---� A3 40 43 I I i I I I I I 43 U) 43 / /1 ly- W t t t t t U) 40 40 I 43 43 40 T / / 40 7_zz/ ;Z 43 43 1 SOLVER CL UD DR I I I I I I I I I I CHECKED BY RCE NO. I CHECKED BY RCE NO. I CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATF GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS U SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. OREMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. OPRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB # RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: + + + + + +++ + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL \ WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). /QOpFESS/Al 0D m _ cn xm * No.78314 CIVIC OF CAL�F�� GRAPHIC SCALE 100 0 50 100 200 1 " = 100, I CITY OF DIAMOND BAR I ROADWAY MAINTENANCE PLANS BENCHMARK: PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3 300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT ANAHEIM, CA 92805 F (714) 808-1270 REVIEWED PUBLIC WORKS DEPARTMENT �,aK— V 78314 3/24/201578314 3/24/2015 APPROVED t ., 21��`I 1s.i5 PROJECT NO. DATE Act►�+c� CITY ENGI R.C.E. DATE 01415 3/24/2015 SHEET 5 OF 12 SHEETS JUSTIN L. SMEETS, P.E. R.C.E. No. DATE �\ \` \\ _ BREA CANYON RD 8'X10' 3 40 \ \ \ 5 / \\ 10'X10' 3 5 \ \\ \ \ 43 20'X17' \ 2 I W � , \ > W \ \ 43 \ \ \ \ / 20'X25' 43 2 REVISIONS CHECKED BY RCE NO. CHECKED BY CHECKED BY DATE CHECKED BY RCE NO. DATE GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES', VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. BREA CANYON RD 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS _ PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. - - - - * 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO T- + - 0� -- - - ++* *( REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE O� *++ ENGINEER OR INSPECTOR. i 0-01 + + i d I + + I 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED O z +*+* i I I USING THERMOPLASTIC. + + / 4'X5 2 4'X85' 2 4'X52 2 4'X9' 2 40 6'X73' 2 40 43 20'X13' 2 6' 113 2 U U+++] 4'X11' / 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. ASTLE ROCK D + + + 2 / -- -- --- -- - - - - - - - - - - - - - - + * 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES �SHALL BE REPLACED IN KIND AS THERMOPLASTIC. \\ * *+ + + * + + + t \ \ \ \ \ \ \ \ \ \ \ \ \* * *+*, + * + * �- *�* \ \ \\ ` •\ // 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. 6'X1 7' 6'X46 O'X14' \\ \ 'X33' 20'X96' 40 I �\\ ` \ 16 2 43T__T 2 43 2 2 \ 01 43 2 40 43 1 \ \ CONSTRUCTION NOTES: i 1 i 20X16 2 i \ \ / \ \ \ 43 1 PROTECT IN PLACE. REMOVALS I\ \ 12'X55 3 5 � � 1 // \� ` \\\ - - - - - - - - - - / //���\ \ \ 2 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG O'X105' 64-10) 41 . LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY 2 / / 2 ENGINEER OR INSPECTOR AT JOB SITE. \ 4'X7' 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ \ 2 AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW 4'X28' 2 - - _ _ FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 40 \ 43 4 X17' 2 4'X11 2 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE i 4 7 / 40 A q 4'X19' 2 4'X22' 2 8' 8' X22 2 40 4'X30' 2 APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 6 \ 6 _ �_ C 4' 40' REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC -- -- -- -- -- O 2 � ,� � 4'X80' __ 4 .+ * * OKEp CRFEK� 20'X39' 2 20'X17' 2 6'X30' STANDARD PLAN122-2 GRADE TO DRAIN. + * + + * * * + + *'' * * * * + * /� 2 5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT + + + + + + + + + + + + + + + I - .+fir 4 X7 2 4'X20� RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE -- -- -- -- - -- -- -- \ \ -- -- - + + + +\ 2 A \T T 4'X16' 10'X26' `+*+*+* * \ 40 EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 43 43 6 \ A 6 2 2 4'X28' 2 \ + + + + + + 4'X20' 2/ ' \ 4'X 15' \ + * gO REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB 20'X32' 4'X29' 2 40 40 I AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND * * * + + + + * + + + + + 43 120-2. MATCH EXISTING. 2 + + 43 2 � 43 + + + + + + + + � + + + + � I\ 12'X 6' 2 + � �+ + + + + + + + \ \\ 4'X19' 2 A6 q \+++++ RAMP PER S+ REMOVE IPPWC STDSTING . NO. 1S11-4. CASE 'X", & INSTALL NEWTYPE #DA OPER IPLAN CURB 6 20 28 2 43 + +*) DESIGNATION. 43 4'X26' 2 4 ( + * + + 6'X25' 2 43 P+*+* ADJUSTMENTS i + 12'X12' 2 - - + 6'X40' 2 2 10'X39' 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. CO / 40 (BY OTHERS) __ - - ++ + 4'X24' 2 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 41 4 + 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 12'X41' 2 _ _ � 'n - - +*+'� -43 - _ 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. r ++ \ \ \ \43 II ' ° -+++ PAVEMENT TREATMENT LEGENDS: ++ 43 \ \ I + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY + + I 6'X40' 2 SEAL / 40 \ 43 + \\ �\ WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY CAPE SEAL. + + 43 20'X62' _ i++++ 4'X28' / \ 2� - + 2 WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL 43 \ _ _ +++* - - - - -A ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT / \ I+*+ 1.5" THICK AC OVERLAY. \ \ + + 10'X75' \ \ 41 2 4'X30' r+ J+ 2 SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND �, *1 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE + +/ 40 3 SAW CUT &REMOVE FULL DEPTH STRUCTURAL SECTION, \ 20'X15' 40 , INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL \ 2 + / GEOGRID SYSTEM AS NEEDED). 43 \ 43 p'9S - qp 4'X21' + p!� 2 6'X20 \ \\ 4'X30' 2 2 + + + 43 / +++ ++ \ 6'X32' 2 ++ + + * + 4'X32' 2 41 Mq� 6'X27' 2 + a SFF CN�� 4'X442 +++ + SyFET 10 43 / 43 ++ + 1 4'X7 2 - - + { 2 4'X10' + + i / 43 +++ + + � 4'X28' 2 / + + + + +" / +++* + 43 * 4'X143' 2 �+ + ' + + + + + / 43 �+ o Q�oFESS/p� CO w -' C/) m No. 78314 * GRAPHIC SCALE 100 0 50 100 200 CIV I\_ OF CA\_\F 1" = 100, CHECKED BY RCE NO. CHECKED BY DATE BENCHMARK: PREPARED BY: ONWARD ENGINEERING 300 S. HARBOR BLVD., SUITE 814 SUBMI ANAHEIM, CA 92805 T: (714) 533-3050 REME' F: (714) 808-1270 j".417 'z 0_9"' v 78314 3/24/2015 APPRI JUSTIN L. SMEETS, P.E. R.C.E. No. DATE CITY OF DIAMOND BAR ROADWAY MAINTENANCE PLANS RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT PUBLIC WORKS DEPARTMENT 3,,XS-►z� PROJECT NO. DATE : DATE 01415 3/24/2015 SHEET 6 OF 12 SHEETS ul co F- _z w +++ /�-- 43 + y --�-- -- --- -- -- -- -- _ _ + + +� 40 -� w / I — 41 + +++ sw + + 2 4'X14' ' 4'X16' 2 0 +1 - - + * 43 _Z + + 40 I 6'X25' 2 _ _ + + + - - / + (Y + + + + *I I I++++ Q f + + + F+ + + - - — U) ++ 8'X29' 2 + + 0 F _ I I I*+ I 2 'X10' ++++ 4'X7' 2 O + (* *+ I 40 I -- I -- + + Q 8'X11' 2 ++ \ Q + 40 * + 43 + ++++++ +// + 12'X196'2 I *+ 40 +++ ++++++++++ i4�X9� + +++ + 2 �v +++ / + + + + + + + + + + + + + + + + +++_+++++ + ++ ++ 10'X32'2 _ -- -- + + + + + +r+ + + _ r + + + + +� � 4'X17' i I � + + / 43 - - + + + + -coQ 4 X18' 1 2 + + +++ + + 40 + + + `� C) + 2 + + 43 +++ + + + + + + 4'X 18' + + 2 I � + + I I + + + + 2 4'X20' +++++ + + 4 X23 - 4' 144' + 2 + I + + 2 4'X26' 2 ++++ ,/+++++ 6'X63' 2\ i i 43 \ I I I++++"4'X3 + + 40 + + / 40 , + \ + + 43 + + + ++ 6'X22' - I - - + + + + + \ 4' 20' 43 + + + , 43 + + 40 I I \ I I + + + + + + —4 + I I I � + ++ ++ Z 41 izs + ++ ++ + + + 2 U \ \ �— I*+*+ + + I \ + Z + + 1 + 4'X17' , I 0 \ I I ++ 4 X101' + + + 43 *+++++ 2 CO \ I+*+ � 2 43 ,/ 40 �`� ++++ 4'X59' 2 - - I \ + + \ 1 +++++\ 2 I I I * * Al, 40 � `ZO'X36' 2/ + ++++ - - - - - - \ \ I++ * 4'X48' + + + ++ + , // +��+++� 2 4'X31' S'X38�' 'X7' 2 4'X40' 4X20' \\ - - * * 2 + + ++ +� OX118' / ��*++++ 40 43 6'X8' 2 40 2 10'X15' 4'X61' 2 g'X21' +*+ - - / Q + + +> �+ + 2 / / + + + + +� 2 40 43 40 4'X 0' \ 2 1+ + + / + + + 2 I \ + + \ �v ++/ ' ++++ -i + * + + + + CASTLE ROCK RD 6'X39' 2 + + 40 + , + + + + +++ + + +++ + + + —+ �� - + + + + + + + + + + + + + + + +++++++ +++++++ + + / 12X118' ++++ + + ++ +A— T /\ + + + + + + + + + + + + Q + + + + - / + + + ' 12'X40 - - /, ? / + + + / I+ + + + 43 / 2 2 4'X27' - - - - - - - - - - - U + + � 4'X13' ++++++•+ +�+++ cn .++ 43 2 +++ •-�- -� Qw +*+++* + + + , 2 'X20' 40 +++++ + / + 6'X44' 43 + / T 12' + T T X5 ' 40 43 / / I , 4'X2 I 2 4'X14' 40 4 X38' I 2 8 I 2 6'X120' j., I i I I I I I 43 I I I I 2 6 X 0 2 � +4'X2743 / +++ + / 26'X74'2 6'X10 I 2 + + Al + , /', 2 20'X78' ,* ++* 6'X30' 2 10'X13' *+ 4'X56' 2 + + + + 10 X 8' // / + + + +� 2 + + 2 -- --- - -- -- -- - I + + _ _ + I 6'X38' 2 + + + 1 52' �+ . ` 20'X98' 2 40 2 4' 18' - - - - 10'X38' 2 - + + + - - ' + + 2 + 18'X41' 12'X 12'X38' T + + 6'X49' ' 2 2 �* + I 2 +++ + + ,✓ , + 2 / `\ / + + 40 2 4'X19' I 4'X29' 2 20'X31' /+ +{ / + + + CROO ED 43 40 10'X31' * * +i 40 * CRE K DR ++++� \ 2 10'X16' +++++ / � Q"/ �* ++ + -- -- - -- -- -- -- -- / 12'X40' 2 / + + + `+ + 43 + + — -- -- / + 43 + + V 20'X52' + _+ + + + + + + + + + + + + + + + + + + + + + + `+ `++ + + + + + * 40 O + + + + + + + + + . + . + + + + + + + + + + + + + + + + + + `+ `+ + + + + + 40 2 ++� + +++++ + V0 __ ++ +++++ / + + 6X9 -- - -- -- __ + + � ++ 20'X44' 2 W I * 2 ++ + + + = 2 'X103' 2 + 4' 10' + * + + +++ \ �+ 41 U 43 ++ 4'X1 2 8 X7 2 4'X14' i 43++ + + + 4 X9 2 \ 2 �. + + + a 20'X51' 2 1 I+ + 2 i+++++ _ Q * 4'X10" 4'X15' 2 'X14' + + +++ +, ' *I 2 2 + + + / 40 + - - ++ 4X39 2 2 4'X7' 2 / + + / ` 41 +* 4'X24' 2 20'X12' 2 O� + + + 4'X16' 2 2 + + +/ , + + i 20'X12' 2 �� / + 4'X13' 2 + +I Q / + I I 5 43 I+*++ 4'X4' 2 14'X43' i Q ® ++++ 2 40 40 O� * * _ + + 'X13' 2 G + + + RISING STAR D * 4'x6' 2 41 \ + + + +--- T _ - - - - + + + + + + + / 43 ---y +++ +_++++++ + +++++++ +++—_ ++ / 2 4'X20'I I 4'X7 2 43 4'X25' "+++++++/ / �� I 4'X18'I 2 4'X9 2 + + , +++ I gN10�/p BqR B` ,' I i I 2 4'X25' 2 43 ,+++ % i I I 40 ++*+ 4X28' + + 2 I I I I + + + — + + w CC) Z I­- -w I U = Q w + + + T :�i w ++ ++ REVISIONS BENCHMARK: CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY CHECKED BY DATE CHECKED BY DATE RCE N0. CHECKED BY DATE PREPARED BY: ONWARD ENGINEERING 300 S. HARBOR BLVD., SUITE 814 SUBMITED ANAHEIM, CA 92805 T: (714) 533-3050 F: (714) 808-1270sj REVIEWED ielz r— V 78314 3/24/2015 APPROVED w -�_._s1 JUSTIN L. SMEETS, P.E. R.C.E. No. DATE 1 , ,CITY GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS 2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL 'CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: +++++++++++++ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY \ CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE 3O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE'/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). Q�OFESCC S/p CO No. 78314 * GRAPHIC SCALE Lp1� CIV 11- ��Q 00 0 50 100 200 q�F OF CNo 1 " = 100, � CITY OF DIAMOND BAR ROADWAY MAINTENANCE PLANS RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT PUBLIC WORKS DEPARTMENT 21`1`� 3' 35 IS PROJECT NO. DATE C.E. DATE 01415 3/24/2015 SHEET 7 OF 12 SHEETS + + + + + + + 43 + + + + + + �. + ++ + ++ +++ + + + + + + + + + + + + + + + + + + 40 + + + + + + + , 43 + + \ + + 43//+ ++ \ + * * \ 43 /+ + + / + + ++ \ 43 *+* \ 40 / + + \ ++++ + I I I I I I \ 43 + + + + + w X14 2 4'X18' 2 4'X 4' 2 4 X9' 2 6'X13' 2 4'�C12' / /� ` +, + +�+ +�+ / \ 43 N\ w - -J 43 W + + + + + + + + + + + + + ��+ �� + + + + \ + + + + + + + + + + + + + + + + + + + + + 43 + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + �� �/ + + \ U cn ,� ___� + �_ + + �t + + + + + + + 4'X1 + + , + + Q w - - - - - - = + +'+' + `SVNB 2 , �, /,+++ \+++ 4'X18' 2 \ \\ 43 + + + + \ � LLJ 4'X12' + +' RAG % / r++**� + + - 2 43 40 4'X4 ' + + + /� / ' + \ 2 2 6X 0' + + ' ++++++ + 4'X24' 2 + +/ i 2 6'X14' + 4'X17' 2 4'X14' <(/�i ++ + J i + 4'X29' 2 — - - 2 4'X10' ++ + 43 4'X25' 2 /++*+ \ ++ + \ �\ `N \\ 2 \ 4'X25' +3: ++ + 4'X14' +++++ ++\ \ \ 2 / 2 X26' + + , 4'X10' 2 /+++++/ 43 \+++\ 4'SC33' \ ` \ 2 \\ \ \ , I 2 4'X23' �+ + 4'X12' 2 //++ +++/4 X39'+ + + + \ 2+ ++ + + / \ + + ,/ — - - 43 \ 4'X41' 2 i / 2 4'X2 ��++ + /*+++* 43 \ 2 4X7 ++ /� i 2 4'X3' + + ++ * + 12' 2 6 X18' 2 \ \\ ` O A / / 43 40 + +++ + + + + , — MO , 4'X * �+ + + , + \ 4'X41' \ Z +++++++++++++... N1'N�� 2 - ' 43 + + + + + + + + + + + + + + + + + + + 4 3 * 2 \ O \ \ i , + + + \/ — - - + + + —�+ + + + + + �R / / / 2 4 X 4'X2 + + ++ + + 2 6'X140' \ + X51' 2 \ \ \ ++ ++*+*+*+� 40 \ 2 4'X13' ++++ 40 2 4'X29' �+ + + +� �� / 2 4'X27/' ++*+++++++� , 40 �/ / \+ + \�O \\ \ \ O �+ +I 2 43 ++*+ + , 43 / 40 * ++*� \ \+ +\ \ \ \ 2 + + / 43 + \ \ - + \ \ +++++ -- r+ * * +I ** 43 2 10'X33' +++ 4'X30' 2 \ , + + + \ 2 6 X7 4'X 6' X 17' 6'X30 + \ ++� 2 2 ++++ 4'X13' '--A + + 4'X231' ++++ + * 43 , - \ \ / + + + + + + + + + + + + + + + + + + + + + + + + / 40 \ \ + + + + + + ..... ' + + + + + + + + + + + + + , + ... + + + + , * + / -- - - -- + +�+ + + + 40 ,�V + \ 43 \ \ + + + +++ 31' 2 + ++ 10'X40' 2 \ +*+ \ \ \\\ 2 6'X163' 40 43 2 X42' 2 4'X26' 43 + + + + ' + �` �+ +++ + + 4' 80' \ \ �� %+ + , 40 + + + 2 , ++ +/ ++ \ \ 40 +++++ + ' +: + J 43 + + \ \ + �* -� 43 + + + + + + / + + + + + ++ + + + + + 4'X32' \ +++ * */ + 2 43 + + + + + + + + /--A+ 2 \ \ *++ 4'X16' 2 \ +++ \ 4' 10' 2 43 4'X21' 2 , 40 + + + \ \+++ \ \ \ w z-- -- -- -- 43 _, w + + �+�.� 43 + _ _ + + + + + + + + + + + + + + + + + ...... + + + + + 1� + + + 0 (n + + + + + +�_ +�` + + + + + + + + + + + + + + + + 1� ClA + + _ \ \ w + ++++++ + // +*+, 40 \\ \ Z 4'X 1' 2 \` +++�'+ FCC - +++ \\ ' - + \ T T 40 + +�R ��0 , 40 +++1 ' \ ++++++ /�' +++ LCKRD ' \ + + + + + \ �. + + + + + + + + \ \ ++ +++++++++++++ + + + �r + + + + + + + + + + + + + + + + +. 2 6' X21 ' + + \ + + + + + + + + + + + + + - 8X22 (� ++++++++ + +y— 43 + \ - _ 43 /++++ + + 40 `� `� 40 \ +� + + \ i ''' — 00 RISI G STAR DR 43 — — �00/ z ~ -- -- w -- -- -- / + + + + 43 _w + +++++++++�—++ �--r ++ + _++++++++++++++++++++++++'� ++ ++ -- + + + + + + + + + + + + + + + + + + + + + + i \ * i ` +� w ++++++++++ 1 +++++ / \���lll ++++ +- Q<w +* + 4X22/ � + + + + + T + + � �O + + + 2 +_+ + + + + + + + + + 4'X12' � --- 1 1 2 / ; DIAMOND BAR llL IAMONDBARBL — 43 GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS 0 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. OPRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 0 REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGE + + + + WEED ABATE, CRACK SEAL/FILL; AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND O 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). /QOOFESS/p� �co �A m No. 78314 * GRAPHIC SCALE 100 0 50 100 200 CIV �9TF �F CA��FO� 1" = 100' I CITY OF DIAMOND BAR I ROADWAY MAINTENANCE PLANS REVISIONS BENCHMARK: PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3 300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT ANAHEIM, CA 92805 T: (714) 533-3050 REVIEWED F: (714) 808-1270 PUBLIC WORKS DEPARTMENT CHECKED BY RCE N0. CHECKED BY RCE N0. CHECKED BY RCE N0. 78314 3/24/2015 APPROVED �vrl0t1,,(�1�1. �1�1 J. ). ,�. PROJECT NO. DATE CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE A4�nk- • CITY ENGIN R.C.E.3 24 20 JUSTIN L. SHEETS, P.E. R.C.E. No. DATE ' DATE 01415 � � 15 SHEET 9 OF 12 SHEETS A� FF �yyL��F ' SF SyF L��'F ++ / + 43 f \� �O / \ \ �' 41 40 , 40 41 2 1C M 41 \ \ _ \ S C ET ,;+ 20'X147' 10'X34' 2 17 6 10'} \ y�FT \ � \ �� \40\ 43 / ' - \ � \ 41 4'X11 2 40 43 40 T 6 2 + \ ++ \ � 6'X43' 2 \ 4'X10' +++++/ \ i 2 + + \ ++ 2 10'X81 k+++/ 2 8'X95' + + + + ` ` \ 40 40 \ + � \ + +� \ \ \ i 43 40 + +� /� + ` 2 10'X33' �+ � � \ � \ � � � � + 40 /� \ + + + + + 40 ++ +`+ + ` Q 10'X7' �+ + + + / �y 43 40 \10'X8 ++ ++ +++ + + +++/� 4'X2 ' 2 41 + + + \ 40 + + / f + \ 4U � + I \Xl�v.Z !z' + ++ 12'X72' 2 +++ 43 + + \ + + f + 40 \\ + 16'X70' 2 + \ \ + + !++++++ 43 41 43 + 12'X54' 2 , 40 43 + + 40 \ i I++ ++I - - - 2 4'X49' \ +++ + 12'X20' \ ++ ++ 2 2 8 X 2 II � 2 10'X21' I\ + * 43 43 I i 12 4'X41' 43 2 'X54' I + + T � 43 � \\ + + 43 ' 40 +++++ , \ 20'X23' 2 _ _ �+ + +++ + +++++ +++++ + + + +�% + 10'X28' 2 \ + + + +++++_ 2 + 10'X51 2 40 + i+ + 6'X42' 2 \ � 40 40 43 + 40 20'X65' 2 I + O * + + 2 12'X51' +� 2 8'X10' ++++++ i 43 + + + + + + + 4'X20' � 2 i � 2 4'X70' r _ - + + j v / 4'X11' 2 2 �4'X15' , + +/ 40 43 - - + + i \ 20 X51' / + 10'X51' + 441 4'X67' 2 2 �+ ++ C� 40 ++++ + + + 4'X19' 2 1 \ 43 \ \" / 43 \ I / i i � 41 REVISIONS CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE 43 +++ \ 2 O'X40' _ `+++ + ` 40+ + + + + + + \ 2 20'X28' + \ +++ + + + + + + + + + + + + ` 4'X150' ++ / � \2 +✓ r /++++ j 43 \ +++ 2 20'X30' /+++/ , \ + + + + + + + + + 40 + + + + + + + + + + + + 43 + + + + + + + + + + + + + + + + + + + + + � 43 MATCHLINE MATCHLINE SEE SHEET 11 SEE SHEET 11 ++ + + + + + + + + �* * + + + 42' + 43 + + + + + + + + + + + 4 3 + + + + I ++ I I + 2 + + 4'X32' + +� + . \ I 43 + + +*+* 4'X8' 11 2 4'X28' + 43 + + 2 r+ + f' + *,+ r* _ _ � FAIR IND LN + 43 + ++ r- +++ +*% 2 4'X54' +++ + +++. + + + + + �. + ++++ + + 40 + 4'X15' 2 40 + + + + 4' 21' 2 + ++ + + ++ \ + + /+ + 43 %' + + + \ + + + +++ 43 + + + I + + 43 \ O + + + 1 + /++ \ , ++ VO 6'X37' 2 \ \ I Qi + + + / \ ' + + \ \ + 4'' 0 + 4X222 i + � 2 12'X1 * ` + + \ + + 4 X6 2 + + + ++ ++` 43 ++++ \ * * + + + + + + + * + X32' 2 \ ,✓/ 43 4'X6' 2 \ 4'X78' 2 GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: OPROTECT IN PLACE. REMOVALS 2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB # RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: `++++++++++++ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY \ CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). Q�pFESS/p L �l No. 78314 * GRAPHIC SCALE 100 0 50 100 200 s CIVILiiiiii �qlF OF CAL�i" = 100, CITY OF DIAMOND BAR ROADWAY MAINTENANCE PLANS BENCHMARK: PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3 300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT ANAHEIM, CA 92805 T: (714) 533-3050 REVIEWED PUBLIC WORKS DEPARTMENT F: (714) 808-1270 78314 3/24/2015 APPROVED *'; ,, � ,. s :" PROJECT NO. DATE . CITY ENGINEER R.C.E. DATE 01415 3/24/2015 SHEET 10 OF 12 SHEETS JUSTIN L. SMEETS, P.E. R.C.E. No. DATE 40 ' YX20' 2 %\ + + + / + + - ' \ �_ + 2 6'X47' ` \ 4'X33' 2 / \ ++ ++++++ 4'X30' `* + � \ 2 + + + \ + + + 2 + + 4'X46' ' ++ + 43 +++ + + + + + + 43 + \ +++ - ++ 43 ++ _ \ 40 + + 43 ' \ ++++ / +++� / 2 10X109, ++ 10'X61' +++ + 4'X15' 2 + + + + + + + 2 + + / 43 \++ +\ V++ + +++ + A + +\ \ � + 4'X86' V + + +� /- BAR_ ++ ++ +N ++ \ \ \ +++\\ +1 ++++++ ++ \�++ / + + \ �+ + .+.++ + + + + + +/ 43 ` +++++ \ *+*+ 8'X63' ' ++ +++++++.� ++ 43 +++ 43 \ + + + + 43 \ + + \ ® + ++ + + + + + + + 43 40 20'X29' 2 ` + + + + 40 +++ \ + - ' - - ++++ 201X17' 2 40 V + ++ 1 1 1 1 \ + + i \ *\ 1 + ++++ ++ +++ + 4'X42' ++++ 1 ,/+ + + + + 10'X16' + + 2 20'X114' 43 ++ + + + + + , 2 + 2 10'X75 /+++++/ +++ /' ++� / \ + + + ' \ \ \ \ 1 ++ ++ II I I 1 S ice+ �+ + + + ++ + ++ + ++ ++ + \+++ + ++ + \ \++ + +/ ++ O'X154' BUS" +++++++++ + +10'X752 2 + + ++ ++++++�++ + + + + 43 + + + + + + 40 ++ + `+\t / / +' L \ + + + + + + + + + \ \ + + + + + + + + + + + +� + F + + - + + + Tom+ + + + + + + + + 1 ` + ✓+ +++ ++ +++++++++++++++++++++i ✓- 1 +++ 20'X165'2 +43 ++++ +++++ =++++++++++++++�- 43 40 ++++ ++++ 40 --� �` ++++�. \ 43 /�+++++� \ 43 1 1 + 2 4'X50' + + \ + + + + 4'X147' + \ /++++*/ \ / I 1 1 1 + *+ 2 �+ \ \ + + \ 1 \ 41 +� 2 6'X19' ++++ 43 4 X6 + ++++++ \ \ + + ++++ j I+++ 4'X32' + 2 4 X6 41 40 + + + + / 2 \ + \ / \ I � I + + ++ ++ \ ` � \ + ++ 40 + + �+ + \ R , I + * 4'X11' 2 \ / ++ \ \ 1 I I / + � / + + + / \ Y I +++ + + 12'X95' 2 / /++++ / 41 + + + \ -/ ti 43 + ljj 40 l +++ O ++ 12'X19 2 F y<� yFFT >o MATCHLINE _ SEE SHEET �2 - - - -- - - - - - - -- SEE T CN0NE + + ES + + I 43 + + - + + + + + + + + + + + + + + + ++ - - - /+ + - -- 40 + + --- + J _++43 + + 2 I [+ + + + + /+ + + _ O + + \ ? ++++I /++++/ + / + + + + + + + + + a ++ _ + -� + + +I + - + + _ + _ _ + m 43 of * ' +*1 + _ C) + + - _ + +� + 8'X79' 2 + + 43 + + + + +++++I +� + + + +++� 43 F++ + + F + / O + + + o + 43 + + + 4 p + + 43 + + + + + + + + ++ \ 43 ++++++ 4'X24' / ++++ / 40 40 ++ / REVISIONS y k \ + + + \� ` + + + + + + + +/ + + + +1 + + 1 I / I + + + I / + ++ 4'X51' 1 +++++ 2 � \ ` 40 + + 43 + * 4 + 1 + + + +/ 8'X23' 2 + ✓✓ 4'X19' 2 \ 10'X32' 2 41 \ \ 10'X10' 2 \ \ \ 2 6'X26' I A3 BANBROOK LN + —r—+ + + + + +-+++++++ + ` + + + + + + + + + + + 41 + + + + + + + + + + + + + .�. + 40 8'X24' 2 4'X44' 2 q . G + 3 � N. + NPE /+++ + ++ +1 43 \ /++ ++ 8'X128' 2 G�' f ++++++++ +'+ + + + + + + 43 ++++� \ \\\G �1 + 6'X;2 PAR\NR041 + J ++++RPINGS20'X442 40 - - _ 43 + 43 \ _ 2 43 ,+ 40 ++++ 6'X35' 2 - 2 10'X20' I++ 20'X107' 2 ++++ + + + + Fsy 4'X21I � + + + + ' 2 + i \ - + + + - - ++++ ` M - - + + +I I MATCHLINE - - \ SFF icy \ MATCHLINE SEE SHEET 10 70 SEE SHEET 10 CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE No. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING, CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS 2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 0 SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB # RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: F- ++++++++++++` WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY CAPE SEAL. WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0 -1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND O 2 mam CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). /Q�pFESS/p \\A L . w C/) m No. 78314 * GRAPHIC SCALE 100 0 50 100 200 CNIL �qTF OF CAS \1 " = 100' I CITY OF DIAMOND BAR I ROADWAY MAINTENANCE PLANS PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3 300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT ANAHEIM, CA 92805 T: (714) 808-127127-0 0 REVIEWED F: (714) 808 PUBLIC WORKS DEPARTMENT 78314 3/24/2015 APPROVED _ �7 i�1 3 +`> PROJECT NO. DATE hej, "CITY E I E R.C.E. DATE 01415 3/24/2015 SHEET 11 OF 12 SHEETS JUSTIN L. SMEETS, P.E. R.C.E. No. DATE SEE SHEET 11 REVISIONS I I I I I / I /I I / I I / BENT T I IG LN 4'X25' 2 u+++ ++ ` + +�+ + + +++ + + j-- + + +� i \ $� + + \ ++++ + 2 4'x14' + + + + + + 43 ++ + /+++� 2 +\ 4'X29' j 43 ++ + ++ + &1A rc + \ I 6X15 ++/+++/ 2 � + '++/++++ 26X46 ++ 43 + + + +++++/ \ 40 \\+ + 1 ++++/ 2 4'X48' + + +/ + + + ++ ++ +++/ ��` + + ++++++ 4'X; . + s'S�, + + + 10 0 2 SNP, �� \ II CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE BENCHMARK: PREPARED BY: ONWARD ENGINEERING 300 S. HARBOR BLVD., SUITE 814 ANAHEIM, CA 92805 T: (714) 533-3050 F: (714) 808-1270 J'j �✓ V 78314 3/24/2015 JUSTIN L. SMEETS, P.E. R.C.E. No. DATE SUBMITED GENERAL CONSTRUCTION NOTES: 1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER. 2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED. 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS. 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE ENGINEER OR INSPECTOR. 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED USING THERMOPLASTIC. 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC. 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES SHALL BE REPLACED IN KIND AS THERMOPLASTIC. 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING. CONSTRUCTION NOTES: 0 PROTECT IN PLACE. REMOVALS 2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/ AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE. 4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC STANDARD PLAN122-2 GRADE TO DRAIN. 5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM. 8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND 120-2. MATCH EXISTING. REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB '11# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN DESIGNATION. ADJUSTMENTS 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE. (BY OTHERS) 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE. 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN. 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE. PAVEMENT TREATMENT LEGENDS: + + + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY SEAL WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY \ CAPE SEAL. K700WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL ROAD 6' WIDE (20' AT JOINS), 0%1.5" THICK, AND CONSTRUCT 1.5" THICK AC OVERLAY. OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND 2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION, INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL GEOGRID SYSTEM AS NEEDED). /QOpFESS/p co co �A m C/) M No. 78314 * GRAPHIC SCALE 100 0 50 100 200 `P C/VIL OF CN01 " = 100, I CITY OF DIAMOND BAR I ROADWAY MAINTENANCE PLANS RESIDENTIAL AREA 3 ROAD MAINTENANCE PROJECT REVIEWED PUBLIC WORKS DEPARTMENT APPROVED vv ( i . ' PROJECT NO. DATE ACJ'4j� CITY EN II En 0 R.C.E. DATE 01415 1 3/24/2015 SHEET 12 OF 12 SHEETS