HomeMy WebLinkAboutPlansCITY OF DIAMOND BAR
Z
C
PROJECT SITE
VICINITY MAP
NTS
AGENCIES TO BE NOTIFIED
SERVICES
CONTACT
TELEPHONE NO.
CALTRANS - DISTRICT 7
--
(213) 897-3631
LORBEER MIDDLE SCHOOL
--
(909) 397-4563
L.A. CO. DEPT. OF PW -
(626) 458-1708
OPERATION SERVICES
L.A. CO. DEPT. OF PW -
(626) 458-7117
SEWER MAINTENANCE
L.A. CO. FIRE DEPT. -
(909) 598-4290
STATION 119
L.A. CO. FIRE DEPT. -
(909) 861-5995
STATION 120
L.A. CO. FIRE DEPT. -
(909) 396-0164
STATION 121
L.A. CO. SHERIFF'S DEPT.
--
(909) 595-2264
POMONA UNIFIED SCHOOL DISTRICT
--
(909) 397-4800x3069
WASTE MANAGEMENT
--
(800) 266-7551
CLEAR CHANNEL OUTDOOR
KEVIN KOCIC
(213) 305-0045
LA CO. DEPT. OF PW -
MARSSA MORELOS
(626) 300-3365
ROADWAY
CROWN CASTLE
DAVID ANTOL
(724)416-2180
SC GAS BREA - TRANSMISSION
ROSALYN SQUIRES
(818)701-4546
SC GAS - INDUSTRY
PETER SERRANO
(714)634-5067
SOUTHERN CALIFORNIA EDISON
CINDY VERRENGIA
(714) 895-0188
SOUTHERN CALIFORNIA EDISON -
MIROSLAVA LICON
(909) 592-3761
DISTRIBUTION
SOUTHERN CALIFORNIA EDISON -
RICHARD OROZCO
(909) 394-2814
TRANSMISSION
SOUTHERN CALIFORNIA EDISON -
ERIC LOPEZ
(626) 422-9256
TRANSMISSION
VERIZON - POMONA
ARIEL FATALLA
(909)469-6333
WALNUT VALLEY WATER DISTRICT
ED CASTANON
(909) 595-1268 x267
METROPOLITAN WATER DISTRICT
FRANCISCO FLORES
(213)217-6679
REVISIONS
CHECKED BY RCE NO. CHECKED BY RCE NO.
CHECKED BY DATE CHECKED BY DATE
CHECKED BY
RCE NO.
CHECKED BY DATE
DEPARTMENT OF PUBLIC WORKS
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
PROJECT NO.01415
BENCHMARK:
hL
PREPARED BY: ONWARD ENGINEERING
300 S. HARBOR BLVD., SUITE 814
ANAHEIM, CA 92805
T: (714) 533-3050
F: (714) 808-1270
jj /7 'z
78314 3/24/2015
Justin L. Smeets, P.E. R.C.E. No. DATE
QOoFESS
l
L
co
c� ) m
� x
* No.78314
s civic
�qTF OF CA��F�/
SUBMITED
REVIEWED
APPROVED !` ;
CITY ENGINEER R.C.E. DATE
SHEET SCHEDULE
SHEET NO.
DESCRIPTION
1
TITLE SHEET
2
RESIDENTIAL AREA 3
3
RESIDENTIAL AREA 3
4
RESIDENTIAL AREA 3
5
RESIDENTIAL AREA 3
6
RESIDENTIAL AREA 3
7
RESIDENTIAL AREA 3
8
RESIDENTIAL AREA 3
9
RESIDENTIAL AREA 3
10
RESIDENTIAL AREA 3
11
RESIDENTIAL AREA 3
CITY OF DIAMOND BAR
TITLE SHEET
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
DEPARTMENT OF PUBLIC WORKS
PROJECT NO. DATE :
01415 1 3/24/2015 SHEET 1 OF 12 SHEETS
' \ I
\ I I
\o I
41
2 2 'X24'
I I I
I
40 x
40 ** 20'X20' 2 O
I �
41 40 ***; 0
41
o*t ° 0 0 0
�
t
*t O
+ * t O O
3 +* O O O
O O
t xxttx*�
O
x t
3
x
\ *+**
43 O
\41 ' 40 ++t* I 0 0 u
\ t O I O
Z / 41 *+t * 40 O O O O O
0000 O
41 � I � O O
O
O
m + 2
+ O
/o 0 0 O1 0
o 40 I * * +
+* tt/ O O O O O O
O O 40 3
/ + 40 t * O
O
- A / +*+t * O O
+ 0 O
41
WOODVI CT 0
* * O O
40 ' tt +/ 0 0 / 0
\\�\ - - O
*t
41 .* +t
t
t
O
-- I 2 4'X20' r, ttt+ 43 O O 0 O O O
O
41 I \ Y*+t*+/ 6'X15' 2 0 O 0 O 0
— — 06'X17' 2 4'X55' 40 8 X ' 2 6'X21' 2
40 * t+ 2
6'X14' 2 40 0 O 40
RAVENWOD T **+•*t.+*+*t* ++�- --�*0+ * `+++*.**++ ++t t' *+****+*' *x
41 40
40 41
43 _ �+ ++ ++ 43
* x x x
Q / *+/++* t 43
— * 8'X62' 2
t + * + ++ 2 6,X6, * ++� + +
—41 ** 4'X82' 2 -- +++ +t** t*
6 CJ
*t + tt *t+ 4'X4' 2
43
��
* x x
* 43 + +
t + +
CID
/' *t *f' + + ? l+ + t. tx * 4'X6'
<C/t.
o *
43
*
t
t
x +
�x +
x
x *
t + * t *
x *
4'X13' 2 �.
t
+ t +
+* +*
+
+
43
I —
\
I
\
/
\ I
I /
\
REVISIONS
CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO.
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE
BENCHMARK:
00
O
O
00
O
O
00
O
O
00
O
00
O^
I �
I /
I / /
I / /
I /
43 /
i
I , ,
I /
�
I
I
/ I
I
43
i 1
6'X 16' 2
40
43
L2
I
I
X31' \p
X 13' 2
10' 1
2
11' 2
43
D
4'XlQ' 2
6'X11'
2
I
I
W�
+ Z
x x ** ** t x t S
t tom* * * Lu
�w
cn
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
10 PROTECT IN PLACE.
REMOVALS
20 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3o SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4o REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8o REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
+++++++++++*+ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
O
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
L
r
t
C
L
Q� IFESS/p
L . ,
—� m
c�
No. 78314
*
GRAPHIC SCALE =
100
(P
0 50 100 200
C/VIL
OF CAL�1 " = 100'
(
CITY OF DIAMOND BAR r
ROADWAY MAINTENANCE PLANS
PREPARED BY: ONWARD ENGINEERING
RESIDENTIAL AREA 3
300 S. HARBOR BLVD., SUITE 814
SUBMITED
ROAD MAINTENANCE PROJECT
ANAHEIM,
CA 92805
T: (714)
F: (714)
533-3050
808-1270
REVIEWED
`
PUBLIC WORKS DEPARTMENT
78314 3/24/2015
APPROVED y
a1>.iFa CITY EN9NEEf f
) Iq -5
R.C.E.
PROJECT N0.
DATE
JUSTIN L. SMEETS, P.E.
R.C.E. No. DATE
DATE
01415
3/24/2015
SHEET 2 OF 12 SHEETS
r
GENERAL CONSTRUCTION NOTES:
%7
43
i
x
/ * � 43
+
x %
\ O ,
40-
%
43
0 \
x
43
% x
40
Ns
Al
40
/
40
x
%
43
43
x /
43 \ \ %� * LL +\*+* **� - - R/DGE O 43
% + /
NTDR 43 43
A n)40
43
43
% +
43
40 I 43 \
x
43 \ \
xx x 43
%x xx x
-
x
40
x x x 40
�xx 43
x x
x % %
43 I '
'
%x I /
% xx xx
x�x '` x 43
�x x I
x
x% *
40
\',xxx % z x xxx xxx 43 43
x x x
S DIAMOND CANYON R 43
x x
% x %
xxxx x x -� x /xxx % % x�' 43
43 x %\
x x x x x x _
xx -,._ %
x x x x
/ x x
x x/�
REVISIONS
CHECKED
BY
RCE NO.
CHECKED
BY
RCE NO.
CHECKED
BY
RCE NO.
CHECKED
BY
DATE
CHECKED
BY
DATE
CHECKED
BY
DATE
BENCHMARK:
PREPARED BY: ONWARD ENGINEERING
300 S. HARBOR BLVD., SUITE 814
ANAHEIM, CA 92805
T: (714) 533-3050
F: (714) 808-1270
i� 78314 3/24/2015
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
SUBMITED
REVIEWED
/1k
F
APPROVEd\-�i' ,
.4' CITY ENGINEFR R.C.E.
DATE
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
0 REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN ,AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
\ CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
O
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
O SAW CUT & REMOVE FULL DEPTH (STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
Q�OFESS/co co
0�
�+ m
L � �
* No. 78314 * GRAPHIC SCALE
100 0 50 100 200
`P C/VIA
�qTF OF CA\_\F 1 " = 100,
I CITY OF DIAMOND BAR I
ROADWAY MAINTENANCE PLANS
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
PUBLIC WORKS DEPARTMENT
PROJECT NO. DATE :
01415 1 3/24/2015 SHEET 4 OF 12 SHEETS
41
i� ------
43
/ — I + +'
9S �` * +� I , 40
/ ,CO 2 6'X33' ++ +
��<r A_ \\\ 2/ �� 1 // I 41 40 OHAN CT 41
10 X22
\ 2 1+
41
'9< 43 \ \ 40
`0� \� ' / \ 27' 2
T
' 40
43
i
-- ' / \
43 +++ '
— — I
6'X17' I++ 40 I
_ + I 1 1 1
3 T U + + I JI
I — — — /
A I I I I I I Q W +' — -- /
3 41 40 41 A 40
3 A +I
FALLOW,, 2 10'X152' I
3 + A 3 40
R 41 41
40
41 S
Lu
co
I 40 41 _ — w
41 cf)
I I I —
I
REVISIONS
57 FREEWAY
I 1
I 1
1
1
I I I I 40
I I I I I I I I I I I I I I I I I I
43 43
I I I I
/ / 77//=
ZY
I I
I I
I I
I I
1 1
43 I 1 40 1 40 43
IGGER LN
40 43 43 --——�---� —�---� A3
40 43
I I i I I I I I
43
U)
43 / /1 ly-
W
t t t t t U)
40
40 I 43 43 40
T / / 40
7_zz/ ;Z 43
43 1 SOLVER CL UD DR
I I I I I I I I I
I
CHECKED BY RCE NO. I CHECKED BY RCE NO. I CHECKED BY RCE NO.
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATF
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
U SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
OREMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
OPRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
+ + + + + +++ + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
\ WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
/QOpFESS/Al
0D
m
_ cn xm
* No.78314
CIVIC
OF CAL�F��
GRAPHIC SCALE
100 0 50 100 200
1 " = 100,
I CITY OF DIAMOND BAR I
ROADWAY MAINTENANCE PLANS
BENCHMARK: PREPARED BY: ONWARD ENGINEERING
RESIDENTIAL AREA 3
300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT
ANAHEIM, CA 92805
F (714) 808-1270 REVIEWED PUBLIC WORKS DEPARTMENT
�,aK— V 78314 3/24/201578314 3/24/2015 APPROVED t ., 21��`I 1s.i5 PROJECT NO. DATE
Act►�+c� CITY ENGI R.C.E. DATE 01415 3/24/2015 SHEET 5 OF 12 SHEETS
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
�\ \` \\ _ BREA CANYON RD
8'X10' 3 40 \ \ \
5 /
\\ 10'X10' 3 5 \ \\
\ \ 43 20'X17'
\ 2 I W �
, \ > W \ \
43 \ \ \ \
/ 20'X25' 43
2
REVISIONS
CHECKED BY RCE NO. CHECKED BY
CHECKED BY DATE CHECKED BY
RCE NO.
DATE
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES', VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
BREA CANYON RD 3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
_ PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
- - - - * 4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
T-
+
- 0�
-- - -
++* *( REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
O�
*++ ENGINEER OR INSPECTOR.
i 0-01 + +
i d I + + I 5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
O z +*+* i I I USING THERMOPLASTIC.
+ + /
4'X5 2 4'X85' 2 4'X52 2 4'X9' 2 40 6'X73' 2 40 43 20'X13' 2 6' 113 2 U U+++] 4'X11' / 6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
ASTLE ROCK D + + + 2 /
-- -- --- -- - -
- - - - - - - - - - - - + * 7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
�SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
\\ * *+ + + * + + + t
\ \ \ \ \ \ \ \ \ \ \ \ \* * *+*, + * + * �- *�* \ \ \\ ` •\ // 8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
6'X1 7' 6'X46 O'X14' \\ \ 'X33' 20'X96' 40
I �\\ ` \
16 2 43T__T 2 43 2 2 \ 01
43 2 40 43 1 \ \ CONSTRUCTION NOTES:
i 1 i 20X16 2 i \ \ / \ \ \ 43 1 PROTECT IN PLACE.
REMOVALS
I\ \ 12'X55 3 5 � � 1 // \� ` \\\
- - - - - - - - - - / //���\ \ \ 2 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
O'X105' 64-10)
41 . LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
2 / / 2 ENGINEER OR INSPECTOR AT JOB SITE.
\ 4'X7' 3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
\ 2 AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
4'X28' 2 - - _ _ FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
40 \ 43 4 X17' 2 4'X11 2 6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
i 4 7 /
40 A q 4'X19' 2 4'X22' 2 8' 8' X22 2 40 4'X30' 2 APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
6 \ 6 _ �_ C 4' 40' REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
-- -- -- -- -- O 2 � ,� � 4'X80' __ 4
.+ * * OKEp CRFEK� 20'X39' 2 20'X17' 2 6'X30' STANDARD PLAN122-2 GRADE TO DRAIN.
+ * + + * * * + + *'' * * * * + * /� 2 5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
+ + + + + + + + + + + + + + + I
- .+fir 4 X7 2 4'X20� RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
-- -- -- -- - -- -- -- \ \ -- -- - + + + +\ 2
A \T T 4'X16' 10'X26' `+*+*+* * \ 40 EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
43 43 6 \ A 6 2 2 4'X28' 2 \ + + + + + + 4'X20' 2/ '
\ 4'X 15' \ + * gO REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
20'X32' 4'X29' 2 40 40 I AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
* * * + + + + * + + + + + 43 120-2. MATCH EXISTING.
2 + +
43 2 � 43 + + + + + + + + � + + + + �
I\ 12'X 6' 2 + � �+ + + + + + + +
\ \\ 4'X19' 2 A6 q \+++++ RAMP PER S+ REMOVE IPPWC STDSTING . NO. 1S11-4. CASE 'X", & INSTALL NEWTYPE #DA OPER IPLAN CURB
6 20 28 2 43 + +*) DESIGNATION.
43 4'X26' 2 4 ( + * + + 6'X25' 2
43 P+*+* ADJUSTMENTS
i +
12'X12' 2 - - + 6'X40' 2
2 10'X39' 40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
CO / 40 (BY OTHERS)
__
- - ++ + 4'X24' 2 41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
41 4 + 42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
12'X41' 2 _ _ � 'n - - +*+'� -43 - _ 43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
r ++
\ \ \ \43 II ' ° -+++ PAVEMENT TREATMENT LEGENDS:
++
43 \ \ I + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
+ +
I 6'X40' 2 SEAL
/ 40 \ 43 + \\ �\ WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
CAPE SEAL.
+ +
43 20'X62' _ i++++ 4'X28'
/ \ 2� - + 2 WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
43 \ _ _ +++* - - - - -A ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
/ \ I+*+ 1.5" THICK AC OVERLAY.
\ \ + + 10'X75'
\ \ 41 2 4'X30' r+ J+ 2 SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
�, *1 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
+ +/ 40
3
SAW CUT &REMOVE FULL DEPTH STRUCTURAL SECTION,
\ 20'X15' 40 , INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
\ 2 + / GEOGRID SYSTEM AS NEEDED).
43 \ 43 p'9S
- qp
4'X21' + p!�
2 6'X20 \ \\ 4'X30' 2 2 + +
+
43 / +++
++ \
6'X32' 2 ++ +
+ * + 4'X32' 2 41
Mq�
6'X27' 2 + a
SFF CN�� 4'X442 +++
+
SyFET 10 43 / 43 ++ + 1 4'X7 2 -
- + {
2 4'X10'
+ +
i
/ 43 +++
+ + � 4'X28' 2
/ + + + + +"
/ +++* + 43
* 4'X143' 2
�+
+
' + + +
+ +
/ 43 �+ o
Q�oFESS/p�
CO
w -' C/) m
No. 78314 * GRAPHIC SCALE
100 0 50 100 200
CIV I\_
OF CA\_\F 1" = 100,
CHECKED BY RCE NO.
CHECKED BY DATE
BENCHMARK:
PREPARED BY: ONWARD ENGINEERING
300 S. HARBOR BLVD., SUITE 814 SUBMI
ANAHEIM, CA 92805
T: (714) 533-3050 REME'
F: (714) 808-1270
j".417 'z
0_9"' v 78314 3/24/2015 APPRI
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
CITY OF DIAMOND BAR
ROADWAY MAINTENANCE PLANS
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
PUBLIC WORKS DEPARTMENT
3,,XS-►z� PROJECT NO. DATE :
DATE 01415 3/24/2015 SHEET 6 OF 12 SHEETS
ul co
F-
_z w
+++
/�-- 43 + y --�-- -- --- -- -- -- -- _ _
+ + +� 40 -� w
/ I —
41
+ +++ sw
+ +
2 4'X14' ' 4'X16' 2 0 +1 - - + * 43
_Z + +
40 I 6'X25' 2 _ _ + + + - -
/ + (Y
+ + + + *I I I++++
Q f + + +
F+ + + - - — U) ++ 8'X29' 2 + + 0
F _ I I I*+ I
2 'X10' ++++ 4'X7' 2 O + (* *+ I 40
I -- I --
+ +
Q 8'X11' 2
++ \ Q +
40 * + 43 +
++++++ +// + 12'X196'2 I *+
40 +++ ++++++++++ i4�X9� + +++
+ 2 �v +++ / +
+ + + + + + + + + + + + + + +
+++_+++++ + ++ ++ 10'X32'2 _ -- --
+ +
+ + + +r+ + + _ r
+ + + + +� � 4'X17' i I � + +
/ 43 - - + + + + -coQ 4 X18' 1 2 + +
+++
+ +
40 + + + `� C) + 2 + +
43 +++ +
+ + + + + 4'X 18'
+ + 2 I � + + I I
+ +
+ +
2 4'X20' +++++ + +
4 X23 -
4' 144' + 2 +
I + +
2 4'X26' 2 ++++ ,/+++++ 6'X63' 2\ i i 43 \ I I I++++"4'X3
+ +
40 + + / 40 , + \ + +
43 + + + ++ 6'X22' - I - -
+ + + + + \
4' 20' 43
+ + + , 43
+ + 40 I I \ I I + +
+ + + + —4
+ I I I � +
++ ++ Z 41
izs
+ ++ ++ + + + 2 U \ \ �— I*+*+
+ + I \
+ Z + +
1 + 4'X17' , I 0 \ I I ++ 4 X101'
+ + +
43 *+++++ 2 CO \ I+*+ � 2
43 ,/ 40 �`� ++++ 4'X59' 2 - - I \ + +
\ 1
+++++\ 2 I I I * *
Al, 40 � `ZO'X36' 2/ + ++++ - - - - - - \ \ I++ * 4'X48'
+ + + ++ + , // +��+++� 2 4'X31' S'X38�'
'X7' 2 4'X40' 4X20' \\ - - * * 2
+ +
++ +� OX118' / ��*++++ 40 43 6'X8' 2 40 2 10'X15' 4'X61' 2 g'X21' +*+ - -
/ Q + + +> �+ + 2 / / + + + + +� 2 40 43 40 4'X 0' \ 2 1+ +
+ / + + + 2 I \ + +
\ �v ++/ ' ++++
-i + * + + + + CASTLE ROCK RD 6'X39' 2 + + 40
+ , + + + + +++ + + +++ + + + —+ �� -
+ + + + + + + + + + + + + +
+ +++++++ +++++++ + +
/ 12X118' ++++ + + ++ +A— T
/\ + + + + + + + + + + + + Q + + + + -
/ + + + ' 12'X40 - -
/, ? / + + + / I+ + + + 43 / 2 2 4'X27' - - - - - - - - - - - U + +
� 4'X13' ++++++•+ +�+++ cn
.++ 43 2 +++ •-�- -� Qw
+*+++* + + + , 2 'X20' 40 +++++
+ / + 6'X44' 43
+ / T 12' +
T T X5 ' 40 43 / / I , 4'X2 I 2
4'X14' 40 4 X38' I 2 8 I 2 6'X120' j.,
I i I I I I I 43 I I I I 2 6 X 0 2 � +4'X2743 / +++ + / 26'X74'2 6'X10 I 2
+ +
Al + , /', 2 20'X78' ,* ++* 6'X30' 2 10'X13' *+ 4'X56' 2
+ + + + 10 X 8' // / + + + +� 2 + +
2
-- --- - -- -- -- - I + +
_ _ + I 6'X38' 2
+ + + 1 52' �+ . ` 20'X98' 2 40 2 4' 18' - - - - 10'X38' 2 - + + + - -
' + + 2 + 18'X41' 12'X 12'X38' T + +
6'X49'
' 2 2 �* + I 2
+++
+ + ,✓ , + 2
/
`\ / + + 40 2 4'X19' I 4'X29' 2 20'X31' /+ +{
/ + + + CROO ED 43 40 10'X31' * * +i 40
* CRE K DR ++++�
\ 2 10'X16' +++++ / � Q"/ �* ++ + -- -- - -- -- -- -- -- / 12'X40' 2
/
+ + +
`+ + 43 + + — -- -- /
+ 43
+ + V 20'X52' + _+ + + + + + + + + + + + + + + + + + + + + + + `+ `++ + + + + +
* 40 O + + + + + + + + + . + . + + + + + + + + + + + + + + + + + + `+ `+ + + + + + 40
2 ++� + +++++ +
V0 __ ++ +++++ /
+ + 6X9 -- - -- -- __ + +
� ++ 20'X44' 2 W I * 2 ++ + +
+ = 2 'X103' 2 + 4' 10' + * + + +++
\ �+ 41 U 43 ++ 4'X1 2 8 X7 2 4'X14' i 43++ + + + 4 X9 2
\ 2 �. + + +
a 20'X51' 2 1 I+ + 2 i+++++ _
Q * 4'X10" 4'X15' 2 'X14' + + +++ +,
' *I 2 2 + + + / 40
+
- - ++ 4X39 2 2 4'X7' 2 / + + /
` 41 +* 4'X24' 2 20'X12' 2 O� + + + 4'X16' 2
2 + + +/ ,
+ + i 20'X12' 2 �� / + 4'X13'
2
+ +I Q / +
I I 5 43
I+*++ 4'X4' 2 14'X43' i Q ® ++++
2 40
40 O� * * _
+ + 'X13' 2 G +
+ + RISING STAR D * 4'x6' 2
41 \ + + + +--- T _ - - - - + +
+ + + + +
/ 43 ---y +++ +_++++++ + +++++++ +++—_ ++
/ 2 4'X20'I I 4'X7 2 43 4'X25' "+++++++/ /
�� I 4'X18'I 2 4'X9 2 + + ,
+++
I gN10�/p BqR B` ,' I i I 2 4'X25' 2 43 ,+++ %
i I I 40 ++*+ 4X28'
+ + 2
I I I I + + +
— + +
w CC)
Z I-
-w
I U =
Q w
+ + + T :�i w
++
++
REVISIONS
BENCHMARK:
CHECKED BY RCE NO. CHECKED BY RCE NO.
CHECKED BY
CHECKED BY DATE CHECKED BY DATE RCE N0.
CHECKED BY DATE
PREPARED BY: ONWARD ENGINEERING
300 S. HARBOR BLVD., SUITE 814 SUBMITED
ANAHEIM, CA 92805
T: (714) 533-3050
F: (714) 808-1270sj
REVIEWED
ielz
r— V 78314 3/24/2015 APPROVED w
-�_._s1
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE 1 , ,CITY
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL 'CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
0 PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
+++++++++++++ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
\ CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
3O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE'/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
Q�OFESCC
S/p
CO
No. 78314 * GRAPHIC SCALE
Lp1� CIV 11- ��Q
00 0 50 100 200
q�F OF CNo 1 " = 100,
� CITY OF DIAMOND BAR
ROADWAY MAINTENANCE PLANS
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
PUBLIC WORKS DEPARTMENT
21`1`� 3' 35 IS PROJECT NO. DATE
C.E. DATE 01415 3/24/2015 SHEET 7 OF 12 SHEETS
+
+ +
+ + + +
43 + + + + + +
�.
+ ++ + ++
+++
+ + + +
+ + +
+ + +
+ + + +
+ +
+ +
40
+ +
+ +
+ + +
, 43 + + \
+ +
43//+
++ \
+ * * \ 43
/+ + + /
+ +
++ \
43 *+* \
40 / + + \
++++ +
I I I I I I \
43
+ + + + +
w X14 2 4'X18' 2 4'X 4' 2 4 X9' 2 6'X13' 2 4'�C12' / /� ` +, + +�+ +�+ / \ 43
N\
w -
-J 43
W + + + + + + + + + + + + + ��+ �� + + + + \
+ + + + + + + + + + + + + + + + + + + + + 43 + + +
+ + + + + + + + + + + + + + + + + + + + + + + + + + + �� �/ + + \
U cn ,� ___� + �_ + + �t + + + + + + + 4'X1 + + , + +
Q w - - - - - - = + +'+' + `SVNB 2 , �, /,+++ \+++ 4'X18' 2 \ \\ 43
+ + + + \
� LLJ 4'X12' + +' RAG % / r++**� + + -
2 43 40 4'X4 ' + + + /� / ' + \
2 2 6X 0' + + ' ++++++ + 4'X24' 2
+ +/
i 2 6'X14' + 4'X17' 2 4'X14' <(/�i ++ + J i + 4'X29' 2
— - - 2 4'X10' ++ + 43 4'X25' 2 /++*+ \ ++ + \ �\ `N \\
2 \
4'X25' +3:
++ + 4'X14' +++++ ++\ \ \
2 /
2 X26' + + , 4'X10' 2 /+++++/ 43 \+++\ 4'SC33' \ `
\ 2 \\ \
\ , I 2 4'X23' �+ + 4'X12' 2 //++
+++/4 X39'+ + + + \ 2+ ++ + + / \
+ + ,/
— - - 43 \ 4'X41' 2 i / 2 4'X2 ��++ + /*+++* 43 \ 2 4X7 ++
/� i 2 4'X3' + + ++ * + 12' 2 6 X18' 2 \ \\ ` O
A / / 43
40 + +++ + + + + , — MO , 4'X * �+ + + , + \ 4'X41' \ Z
+++++++++++++... N1'N�� 2 - '
43
+ + + + + + + + + + + + + + + + + + + 4 3 * 2 \ O \ \
i , + + + \/
— - - + + + —�+ + + + + + �R / / / 2 4 X 4'X2 + + ++ + + 2 6'X140' \ + X51' 2 \ \ \
++ ++*+*+*+� 40 \
2 4'X13' ++++ 40 2 4'X29' �+ + + +� �� / 2 4'X27/' ++*+++++++� , 40 �/ / \+ + \�O \\ \ \ O
�+ +I 2 43 ++*+ + , 43 / 40 * ++*� \ \+ +\ \ \ \
2 + + / 43 + \ \ -
+ \ \ +++++
-- r+ * * +I
** 43 2 10'X33' +++ 4'X30' 2 \ ,
+ +
+ \
2 6 X7 4'X 6' X 17' 6'X30 + \
++� 2 2 ++++ 4'X13'
'--A
+ + 4'X231' ++++ + * 43 , - \
\ /
+ + + + + + + + + + + + + + + + + + + + + + + + / 40 \ \
+ + + + + + ..... ' + + + + + + + + + + + + + ,
+ ... + + + + , * + /
-- - - -- + +�+ + + + 40 ,�V + \ 43 \ \
+ + + +++ 31' 2 + ++ 10'X40' 2 \ +*+ \ \ \\\
2 6'X163' 40 43 2 X42' 2 4'X26' 43 + + + + ' +
�` �+ +++ + + 4' 80' \ \ �� %+ + , 40
+ + + 2 , ++ +/ ++ \ \
40 +++++ + ' +: + J 43 + + \ \
+ �* -�
43 + + + + + + / + +
+ + + ++ + + + + + 4'X32' \
+++ * */ + 2 43
+ + + + + +
+ +
/--A+ 2 \ \
*++ 4'X16' 2 \ +++ \
4' 10' 2 43 4'X21' 2 , 40 + + + \ \+++ \ \ \
w
z-- -- -- -- 43
_, w + + �+�.� 43 +
_ _ + + + + + + + + + + + + + + + + + ......
+ + + + + 1� + + +
0 (n + + + + + +�_ +�` + + + + + + + + + + + + + + + + 1� ClA + + _ \ \
w + ++++++ + // +*+, 40 \\ \ Z
4'X 1' 2 \` +++�'+ FCC - +++ \\ '
- + \
T T
40 + +�R ��0 , 40 +++1 ' \
++++++ /�' +++ LCKRD
' \ + + + + + \ �. + + + + + + + + \ \
++ +++++++++++++
+ + + �r + + + + + + + + + + + + + + + + +.
2 6' X21 ' + + \ + + + + + + + + + + + + + -
8X22 (� ++++++++ + +y— 43
+ \ - _ 43
/++++ + + 40 `� `� 40 \
+� + + \ i
''' — 00 RISI G STAR DR 43 — — �00/
z ~ -- --
w -- -- -- / + + + + 43
_w + +++++++++�—++ �--r ++ +
_++++++++++++++++++++++++'� ++ ++ --
+ + + + + + + + + + + + + + + + + + + + + + i \ * i ` +�
w ++++++++++ 1 +++++ / \���lll ++++ +-
Q<w +* + 4X22/ � + + + + + T + +
� �O + + + 2 +_+ + + + + + + + + +
4'X12' � ---
1 1 2 / ; DIAMOND BAR llL
IAMONDBARBL
—
43
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
0 SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
OPRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
0 REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGE
+ + + + WEED ABATE, CRACK SEAL/FILL; AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
O
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
/QOOFESS/p�
�co
�A m
No. 78314 * GRAPHIC SCALE
100 0 50 100 200
CIV
�9TF �F CA��FO� 1" = 100'
I CITY OF DIAMOND BAR I
ROADWAY MAINTENANCE PLANS
REVISIONS BENCHMARK: PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3
300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT
ANAHEIM, CA 92805
T: (714) 533-3050 REVIEWED
F: (714) 808-1270 PUBLIC WORKS DEPARTMENT
CHECKED BY RCE N0. CHECKED BY RCE N0. CHECKED BY RCE N0. 78314 3/24/2015 APPROVED �vrl0t1,,(�1�1. �1�1 J. ). ,�. PROJECT NO. DATE
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE A4�nk- • CITY ENGIN R.C.E.3 24 20 JUSTIN L. SHEETS, P.E. R.C.E. No. DATE ' DATE 01415 � � 15 SHEET 9 OF 12 SHEETS
A�
FF �yyL��F ' SF SyF L��'F
++
/ +
43 f \� �O / \ \ �' 41
40 ,
40 41 2 1C
M 41 \ \ _ \
S C ET ,;+ 20'X147' 10'X34' 2
17
6 10'}
\
y�FT \ � \ ��
\40\ 43 / ' -
\ � \
41
4'X11 2
40 43
40 T 6
2
+
\ ++
\ � 6'X43' 2 \ 4'X10' +++++/
\ i 2
+ +
\ ++
2 10'X81 k+++/
2 8'X95' + +
+ +
` ` \ 40 40 \ +
�
\ + +�
\ \
\ i 43 40 + +�
/� + `
2 10'X33' �+ � � \ � \ � � � � +
40
/�
\ + + +
+ +
40 ++
+`+
+ ` Q
10'X7' �+ + + + / �y
43
40 \10'X8 ++ ++ +++
+ + +++/� 4'X2 ' 2 41
+ + + \ 40 + +
/ f + \
4U � +
I \Xl�v.Z !z' + ++ 12'X72' 2
+++ 43
+ + \
+ +
f + 40 \\
+ 16'X70' 2
+ \ \
+ +
!++++++ 43 41 43
+ 12'X54' 2 , 40 43
+ + 40 \
i I++ ++I - - - 2 4'X49' \
+++
+ 12'X20' \
++ ++ 2 2 8 X 2 II � 2 10'X21'
I\ + * 43 43 I i 12 4'X41' 43
2 'X54' I
+ + T � 43 � \\
+ + 43 ' 40 +++++ ,
\ 20'X23' 2 _ _ �+ + +++ + +++++ +++++ + + + +�% + 10'X28' 2 \
+ +
+ +++++_ 2 +
10'X51 2 40 + i+ + 6'X42' 2 \
� 40 40 43 + 40
20'X65' 2 I + O * + +
2 12'X51' +� 2 8'X10' ++++++
i 43 + + + +
+ + +
4'X20' � 2 i � 2 4'X70' r _
- + + j v
/ 4'X11' 2 2 �4'X15' ,
+ +/ 40
43 - - + + i \
20 X51' / +
10'X51' +
441
4'X67' 2 2 �+ ++ C�
40 ++++
+
+ +
4'X19' 2 1 \ 43 \
\"
/ 43 \ I /
i
i
� 41
REVISIONS
CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO.
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE
43 +++
\ 2 O'X40' _ `+++
+
` 40+ +
+ + + +
+
\ 2 20'X28' +
\ +++
+ + +
+ +
+ + +
+ +
+ +
` 4'X150' ++ /
� \2 +✓
r /++++ j 43 \
+++
2 20'X30' /+++/ ,
\ + + +
+ +
+
+ + + 40
+
+ + +
+ +
+ + + +
+ + 43
+ +
+ +
+ +
+ +
+ + +
+ +
+ + +
+ +
+ + +
� 43
MATCHLINE
MATCHLINE SEE SHEET 11
SEE SHEET 11 ++ +
+ + + +
+ + +
�* * + +
+
42'
+ 43 +
+ +
+ + +
+ + +
+ + 4 3 + +
+ + I
++ I
I +
2
+ + 4'X32'
+
+� + . \
I 43
+ + +*+* 4'X8' 11 2 4'X28'
+ 43 + + 2
r+ +
f' + *,+
r* _ _ � FAIR IND LN
+ 43 + ++ r- +++
+*% 2 4'X54' +++ + +++. + + + + + �. + ++++
+
+ 40 + 4'X15' 2 40
+
+ + +
4' 21' 2
+
++
+ +
++ \
+ +
/+ +
43 %'
+ +
+
\
+
+ +
+++ 43
+ +
+ I
+ + 43 \
O + + + 1
+
/++ \ ,
++
VO 6'X37' 2 \ \ I
Qi + + + / \
'
+ + \ \
+
4''
0 + 4X222
i + �
2
12'X1 * `
+ +
\ +
+ 4 X6 2
+ +
+
++
++` 43
++++ \
* * + +
+ +
+ + +
* +
X32'
2 \ ,✓/
43
4'X6' 2 \
4'X78' 2
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
OPROTECT IN PLACE.
REMOVALS
2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
`++++++++++++ WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
\ CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0"-1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
Q�pFESS/p
L �l
No. 78314 * GRAPHIC SCALE
100 0 50 100 200
s CIVILiiiiii
�qlF OF CAL�i" = 100,
CITY OF DIAMOND BAR
ROADWAY MAINTENANCE PLANS
BENCHMARK: PREPARED BY: ONWARD ENGINEERING
RESIDENTIAL AREA 3
300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT
ANAHEIM, CA 92805
T: (714) 533-3050 REVIEWED PUBLIC WORKS DEPARTMENT
F: (714) 808-1270
78314 3/24/2015 APPROVED *'; ,, � ,. s :"
PROJECT NO. DATE
. CITY ENGINEER R.C.E. DATE 01415 3/24/2015 SHEET 10 OF 12 SHEETS
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
40 '
YX20' 2
%\ + + + / + + - ' \ �_ + 2 6'X47' ` \ 4'X33' 2
/ \ ++ ++++++ 4'X30' `* + � \
2
+ + + \ + + + 2 + + 4'X46' '
++ + 43 +++
+ + + + + +
43 +
\ +++ - ++ 43 ++ _ \ 40 +
+ 43 '
\ ++++ / +++� / 2 10X109, ++ 10'X61' +++ + 4'X15' 2
+ + + + + + + 2 + + /
43 \++ +\ V++
+ +++ + A + +\ \ � + 4'X86'
V + +
+� /- BAR_ ++ ++ +N ++ \ \ \
+++\\ +1 ++++++ ++ \�++ /
+ + \ �+ + .+.++ + + + + + +/ 43 ` +++++ \ *+*+ 8'X63' '
++ +++++++.� ++ 43 +++
43
\ + + + + 43 \ + + \ ® +
++
+ + + + + + + 43 40 20'X29' 2 ` + +
+ +
40 +++ \ +
- ' - - ++++ 201X17' 2 40
V + ++ 1 1 1 1 \ + + i \ *\
1
+ ++++ ++ +++ + 4'X42'
++++ 1 ,/+ + + + + 10'X16' + + 2
20'X114' 43 ++ + + + + + ,
2 + 2 10'X75 /+++++/ +++ /' ++� /
\ + + + '
\ \ \ \ 1 ++ ++ II I I 1 S ice+ �+ + + + ++ + ++ + ++ ++ + \+++
+ ++ + \ \++ +
+/ ++
O'X154' BUS" +++++++++ + +10'X752 2 + +
++ ++++++�++
+ + + + 43
+ + + + + + 40 ++
+
`+\t
/
/
+' L
\ + + + + + + + + + \ \ + + + + + + + + + + + +� + F
+ + - + + + Tom+ + + + + + + + + 1 ` +
✓+ +++ ++ +++++++++++++++++++++i ✓- 1 +++ 20'X165'2 +43 ++++ +++++
=++++++++++++++�- 43 40 ++++
++++ 40 --� �` ++++�.
\ 43 /�+++++� \ 43 1 1 + 2 4'X50' + + \ + + + +
4'X147' +
\ /++++*/ \ / I 1 1 1 + *+ 2 �+
\ \ + + \ 1 \ 41 +� 2 6'X19' ++++ 43 4 X6 + ++++++
\ \ + +
++++ j I+++ 4'X32'
+ 2 4 X6
41 40 + +
+ + / 2
\ + \ / \ I � I
+ +
++ ++ \ ` � \ + ++
40
+ +
�+ + \ R , I + * 4'X11' 2 \ / ++ \ \ 1 I I /
+ � / +
+ + / \ Y I +++ + + 12'X95' 2 /
/++++ / 41 + + +
\ -/ ti 43
+
ljj 40 l
+++ O ++ 12'X19 2
F y<�
yFFT >o
MATCHLINE _
SEE SHEET �2 - - - -- - -
- - - - -- SEE T CN0NE
+ + ES
+ + I
43
+ + - + +
+ + + +
+ + + + +
+ + + +
++
- - - /+ + -
-- 40 + +
--- + J
_++43 + + 2
I
[+ + +
+ + /+
+ + _ O + + \
? ++++I /++++/ + /
+ + + + +
+ + + +
a ++ _ + -�
+ + +I +
- + + _ + _ _
+ m 43
of * '
+*1
+
_ C) + +
- _ + +� + 8'X79' 2
+ +
43
+ + + +
+++++I +�
+ + +
+++� 43 F++
+ + F
+ / O +
+ + o +
43
+ + + 4 p + +
43
+ + + +
+ + + +
++
\ 43 ++++++ 4'X24' / ++++ / 40
40 ++ /
REVISIONS
y k \
+ + + \� `
+ +
+ + +
+ + +/
+ +
+ +1
+ + 1 I /
I
+
+ + I /
+ ++ 4'X51' 1
+++++ 2 � \ ` 40
+ + 43
+ * 4
+ 1 +
+
+ +/ 8'X23' 2
+ ✓✓
4'X19' 2 \
10'X32' 2
41 \ \
10'X10' 2 \ \ \
2 6'X26'
I A3
BANBROOK LN
+
—r—+ + + + +
+-+++++++ + `
+ + + + + + + + + + + 41
+ + + + + + + + + + + + + .�. +
40
8'X24' 2 4'X44' 2 q . G
+ 3 � N. +
NPE /+++
+ ++ +1
43 \ /++ ++
8'X128' 2 G�' f ++++++++ +'+
+ + + + + +
43 ++++�
\
\\\G �1
+ 6'X;2
PAR\NR041 + J ++++RPINGS20'X442 40 - - _
43 + 43 \ _ 2
43 ,+ 40 ++++ 6'X35' 2 -
2 10'X20' I++ 20'X107' 2 ++++
+ +
+ +
Fsy
4'X21I � + + + +
' 2 +
i
\ - + + + - - ++++
` M - - + + +I I MATCHLINE - -
\ SFF icy \ MATCHLINE SEE SHEET 10
70 SEE SHEET 10
CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE No.
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING,
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
0 SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
F- ++++++++++++` WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
CAPE SEAL.
WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0 -1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
SAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
O
2 mam CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
O SAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
/Q�pFESS/p
\\A L .
w C/) m
No. 78314 * GRAPHIC SCALE
100 0 50 100 200
CNIL
�qTF OF CAS \1 " = 100'
I CITY OF DIAMOND BAR I
ROADWAY MAINTENANCE PLANS
PREPARED BY: ONWARD ENGINEERING RESIDENTIAL AREA 3
300 S. HARBOR BLVD., SUITE 814 SUBMITED ROAD MAINTENANCE PROJECT
ANAHEIM, CA 92805
T: (714) 808-127127-0 0 REVIEWED
F: (714) 808 PUBLIC WORKS DEPARTMENT
78314 3/24/2015 APPROVED _ �7 i�1 3 +`> PROJECT NO. DATE
hej, "CITY E I E R.C.E. DATE 01415 3/24/2015 SHEET 11 OF 12 SHEETS
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
SEE SHEET 11
REVISIONS
I
I
I
I
I
/
I /I
I /
I I /
BENT T I IG LN 4'X25' 2
u+++ ++
` + +�+ + +
+++ + + j-- + + +� i
\ $� + +
\ ++++ + 2 4'x14' + +
+ + + +
43 ++ +
/+++� 2 +\
4'X29' j 43 ++ +
++
+
&1A rc
+
\ I 6X15 ++/+++/ 2 �
+ '++/++++ 26X46
++ 43 + +
+
+++++/ \ 40 \\+ +
1
++++/ 2 4'X48' +
+ +/ + + +
++ ++
+++/ ��` + + ++++++ 4'X;
. + s'S�, + + + 10 0 2
SNP, �� \
II
CHECKED BY RCE NO. CHECKED BY RCE NO. CHECKED BY RCE NO.
CHECKED BY DATE CHECKED BY DATE CHECKED BY DATE
BENCHMARK:
PREPARED BY: ONWARD ENGINEERING
300 S. HARBOR BLVD., SUITE 814
ANAHEIM, CA 92805
T: (714) 533-3050
F: (714) 808-1270
J'j �✓ V 78314 3/24/2015
JUSTIN L. SMEETS, P.E. R.C.E. No. DATE
SUBMITED
GENERAL CONSTRUCTION NOTES:
1. THE LIMITS OF ALL PAVEMENT TREATMENT ARE THE EDGE OF PAVEMENT
AND SLURRY SHALL BE OVERLAPPED 2" AT THE GUTTER.
2. PROTECT -IN -PLACE EXISTING UTILITIES, POLES, VALVES, COVER, AND
OTHER MISCELLANEOUS FACILITIES, UNLESS OTHERWISE INDICATED.
3. THE CONTRACTOR SHALL NOTIFY THE CITY ENGINEER AT LEAST 48 HOURS
PRIOR TO REMOVAL OF ANY EXISTING IMPROVEMENTS.
4. THE CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF SAWCUTTING TO
REMOVE AND REPLACE AC PAVEMENT OR CONCRETE ITEM WITH THE
ENGINEER OR INSPECTOR.
5. ALL BIKE LANE STRIPING AND PAVEMENT MARKERS ARE TO BE INSTALLED
USING THERMOPLASTIC.
6. ALL CROSSWALK STRIPING ALONG ARTERIALS IS TO BE THERMOPLASTIC.
7. ALL EXISTING THERMOPLASTIC LEGENDS WITHIN RESIDENTIAL ZONES
SHALL BE REPLACED IN KIND AS THERMOPLASTIC.
8. BOTS DOTS ARE TO BE INSTALLED ON ALL ARTERIAL LANE STRIPING.
CONSTRUCTION NOTES:
0 PROTECT IN PLACE.
REMOVALS
2O SAWCUT/ COLD MILL 2" EXISTING AC PAVEMENT AND REMOVE EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL 2" AC (B2-PG
64-10). LOCATION AND METHOD OF REMOVAL SHALL BE APPROVED BY
ENGINEER OR INSPECTOR AT JOB SITE.
3O SAWCUT EXISTING PAVEMENT SECTION AND REMOVE 6" OF EXISTING AC/
AGG. BASE/ SUB -BASE/ NATIVE SOIL TO PROVIDE CLEAR DEPTH FOR NEW
FULL DEPTH IMPROVEMENT PER PLANS, HAUL AWAY AND DISPOSE. INSTALL
6" AC (B2-PG 64-10). LOCATION AND METHOD OF REMOVAL SHALL BE
APPROVED BY ENGINEER OR INSPECTOR AT JOB SITE.
4O REMOVE EXISTING IMPROVEMENTS & INSTALL CROSS GUTTER PER SPPWC
STANDARD PLAN122-2 GRADE TO DRAIN.
5O PRUNE AND REMOVE ROOTS WITHIN LIMITS OF PAVEMENT
RECONSTRUCTION. CITY PROVIDED ARBORIST TO REVIEW AND APPROVE
EACH LOCATION'S ROOT PRUNING PRIOR TO CUTTING ROOT SYSTEM.
8O REMOVE EXISTING PCC CURB DEPRESSION AND CONSTRUCT PCC CURB
AND GUTTER, AND SIDEWALK PER SPPWC STANDARD PLAN 112-2, 113-2 AND
120-2. MATCH EXISTING.
REMOVE EXISTING IMPROVEMENTS & INSTALL NEW ADA COMPLIANT CURB
'11# RAMP PER SPPWC STD. PLAN NO. 111-4. CASE "X", TYPE "#" PER PLAN
DESIGNATION.
ADJUSTMENTS
40 ADJUST EXISTING WATER & GASVALVE CAN AND COVER TO FINISHED GRADE.
(BY OTHERS)
41 ADJUST EXISTING MANHOLE FRAME AND COVER TO FINISHED GRADE.
42 INSTALL TRAFFIC LOOPS PER CALTRANS STANDARD TYPE E OR TYPE D, PER PLAN.
43 PROTECT EXISTING MANHOLE AND COVER IN PLACE.
PAVEMENT TREATMENT LEGENDS:
+ + + WEED ABATE, CRACK SEAL/FILL, AND APPLY TYPE II SLURRY
SEAL
WEED ABATE, CRACK SEAL/FILL (AS APPLIES) AND APPLY
\ CAPE SEAL.
K700WEED ABATE, CRACK SEAL/FILL (AS APPLIES), EDGE MILL
ROAD 6' WIDE (20' AT JOINS), 0%1.5" THICK, AND CONSTRUCT
1.5" THICK AC OVERLAY.
OSAW CUT/COLD MILL EXISTING AC PAVEMENT 2" THICK AND
2 CONSTRUCT 2" AC PAVEMENT ON COMPACTED NATIVE/BASE
OSAW CUT & REMOVE FULL DEPTH STRUCTURAL SECTION,
INSTALL 6" AC ON COMPACTED NATIVE/BASE (INSTALL
GEOGRID SYSTEM AS NEEDED).
/QOpFESS/p
co co
�A m
C/) M
No. 78314 * GRAPHIC SCALE
100 0 50 100 200
`P C/VIL
OF CN01 " = 100,
I CITY OF DIAMOND BAR I
ROADWAY MAINTENANCE PLANS
RESIDENTIAL AREA 3
ROAD MAINTENANCE PROJECT
REVIEWED PUBLIC WORKS DEPARTMENT
APPROVED vv ( i . ' PROJECT NO. DATE
ACJ'4j� CITY EN II En 0 R.C.E. DATE 01415 1 3/24/2015 SHEET 12 OF 12 SHEETS