Loading...
HomeMy WebLinkAbout30578 (46)TRIAD FOUNDATION ENGINEERING INC Famdatka ft ft * ftOmft Goolov Ma t*rW Toift * Canumflon Impecdon IMI EAST RAILROAD STREET, SUITE 100, CITY OF INDUSTRY, CA 91748 TELEPHONE (816) W2313 FAX (818) $10401115 Job # 88-494 Sun -Ray 1724 Leaning Pine Diamond Bar, Ca. 91765 Subject: Supplemental Geotechnical Data and Review of Revised Grading Plan 22105 Rim Fire Lane Diamond Bar, Ca. References: Gentlemen: 7') AAR 2 1 ( J, 1) Preliminary Soils & Geologic Investigation by Triad Foundation Engineering, Inc. dated 9-8-88 2) County Geologic Review Sheet dated 11-21-88 Additional geologic data down slope shows a slight steepening of the apparent dip shown on the attached Cross Sections A -A' and B -B'. Stability calculations contained in our Preliminary Report on the natural slope indicate it to have an acceptable factor 6f safety of 1.5. The present grading concept is to place a fill to support the house. As drawn on the plan it appears this fill will slope at an average angle of will be supported by a high cribwall at the property line. It appears this wall will be as high A_p Jp 'ill encroach onto theportionofw restricted, _,VPo area", Th / is area has been designated as an area of shallow slumping and sliding. Access to the house will be by a long driveway from Rim Fire and will also be on fill. The Tract is sewered and the house will be connected to this system. It is expected that no effluent will be introduced into the subsurface. ConclMsions and Recommend4tions 1. The natural slope has an adequate factor of safety. 2. The placement of the proposed fill should.,,,,act as a "buttress" axe--improvethe site stability. 3.A11 fill will, In f In thebeo,roc ' k. r*as .of the ,shallow slumping -a'na, alko-i d# , _,,k vs and benchshallow ir, M101- 1- 1 " 4 . qpp -.P-y benching will be required to'rdkove all disturbed bedrock. 4. The placement of all fill is subject to geologic inspection to insure proper keying and benching are being maintained. 5. The ll, as =alit« has no dr4i,pgp benchs. a e From the top ofI the proposed cribwall to pad grade is estimated to be as high as* 75fi6tIf-appears that,,_thrpe,, J,ght-f pot wide benches mai '- he side of 'tlip p y'. be in oder. TheJ t, Ju c p, , t s e Inror rease the,,,,ile,,i4 6. Proposed fill slopes will be constructed from imported soils whose source is not known at this timef,, Calculations enclosed indicate that a proposedV171"' Tbolt-J,rIgh fill slope can be safely 3-5' , and Cconstructedwithsoilshavift//' strengths ofv, i".1111 3,0,0,/ p/s//,. Any imported soils must be tested and approved by the Soils Engineer prior to importing to insure these minimum shear strengths(' Revised calculations could also be required when better grading plans are available. Fill slopes constructed at 1 1/2:1 gradients must be over filled a minimum three feet and trimmed back to the compacted, inner core. This will be difficult and costly with a large retaining wall at the toe of slope. The opportunity to be of service to you has been appreciated. If you have any questions, please do not hesitate to call. Respectfully submitted, 0 0 K TRIAD FOUNDATION ENGINEERING, INC. f William G. Uhl Frank C. S illman gT, 0 C.E.G. 502 G.E. 805 WGU;FCS/lms Enclosures: c P, m 0 CE RT1F i ED ENG NEER NG GEOLOGIST Geologic Map Cross Sections A & B Slope Stability Calculations Addressee (4) 0 f ESS/ C S C'7 Z5 L -J Exi), 07 -- Ci I. ry ff J I SIVRFICIAL SLOPE STABILITY FLOW LINES SLOPE SURFACE PATH ASSUME: 2) SATURATION TO FAILURE PATH 2) PERMEABILITY SUFFICIENT To PERMIT FLOW Pw - WATER PRESSURE HEAD Ws = SATURATED SOIL UNIT WEIGHT Ww - UNIT WEIGHT OF SOIL WATER U - SOIL PORE WATER PRESSURE Pw - 9 COS2 a U - ww COS2 OL FD - iF VS sin 2 OC pR - Z (WS-Ww) COS2 OC tan 0 + C F.S. 2 M (ws-ffy) cos 2 4 tan 0 + 2a Ws (2) sin 2 F2 (300) 120 (4) sin 68 1.8 PARAMETERS TRIAD FOUNDATION ENGINEERING, Inc. 88-494" 7 0- 3t2l/89 FS PLATEJ06no*. By: ROTATIONAL ANALYSIS USING JANBU'S DIMENSIONLESS PARAMETERS Harvard Soil Mechanics Series No, 46) SECTION Fill Slope SHEAR STRESS PARAMETERS Unit Weight, 'y 120 lbs,./cu.'.ft. Cohesion, C lbs . /sq-. ft- ,.. Angle of Internal Friction, + degrees Tangent .4 CALCULATIONS Height of Section 70 feet Slope of Section 1}.1 YH C 0 2 8 xc YCH Tan + - 19.6 Ncf (from Janbu's curves) 44 FACTOR OF SAFETY F. S. - Ncf YH 1.57 TRIAD FOUNDATION ENGINEERING, Inc. Consulting Geologists - Soils Engineering Jab no: 88-494°,; Date: _ 3121/89 Scale: By; Fs